7.  Recharging Port (note: use this port for all chargers including wall charger, car 

charger, and solar panel charger) 

8.  USB Type-C port 
9.  Cooling Window (noise free) 

 

 PRODUCT SPECIFICATIONS 

 

 

5. INSTRUCTION FOR USE 

  Before first use, please charge battery to 100%. (LED = 

FF

). To charge, first 

plug the wall charger to the wall outlet. Next, connect the wall charger to the 
battery Recharging Port on the side of the battery. 

  To use the battery, you need to turn on the battery first and then the AC Outlet: 

1.  To turn on the battery, press and hold the Battery ON/OFF Switch on the 

top of the battery until the Capacity % LED Display turns ON. 

2.  To turn on the AC Outlet, slide the AC Outlet Switch to ON and the Red 

LED light of the AC Outlet Indicator turns ON. 

  Plug in your device and the device should turn ON and be ready for use. 

  After use, just press and hold the Battery ON/OFF Switch on the top of the 

battery to turn off (LED Display turns off). 
 
 

Summary of Contents for 21160KC

Page 1: ...User Manual Zopec Explore Oxygen Ver 03 03 2021 Page 1 of 10 USER MANUAL Universal CPAP BiPap and Oxygen Battery Professional Model 21160KC...

Page 2: ...s must be done first Otherwise the automatic climate control will turn the heated humidifier and heated tube back ON without notice ii Next turn Humidity Level and Tube Temp to OFF If you don t have a...

Page 3: ...r and heated tube i e ResMed AutoClimate Control o Sleep 16 24 hours with humidifier medium setting and no heated tube o Sleep 42 64 hours without humidifier and heated tube up to 8 nights of sleep So...

Page 4: ...atures 32 115 F 0 45 C Follow the local regulations when disposing the battery 3 PRODUCT DIAGRAM Front of Battery Top of Battery Side of Battery 1 Two 110V AC Outlets note they can power two devices a...

Page 5: ...e wall charger to the battery Recharging Port on the side of the battery To use the battery you need to turn on the battery first and then the AC Outlet 1 To turn on the battery press and hold the Bat...

Page 6: ...FF This UPS battery is designed to stay under the bed If you put in a drawer make sure it is vented This battery comes with all safety features including over current over voltage and over temp It is...

Page 7: ...sunny and cold or overcast weather will not charge nearly as efficiently 5 4 Air Travel NOT COMPLIANT WITH FAA TSA Zopec Explore oxygen has a capacity of 576 Wh and is NOT FAA TSA compliant for air t...

Page 8: ...ries have capacity about 98 Wh or 27 000 mAh Please read your device specification and determine the capacity of your device battery The Zopec Explore Oxygen has a capacity of 576 Wh and 160 000 mAh P...

Page 9: ...ntrol turned the heated humidifier and heated tube back ON without you knowing Please enter MyOptions and make sure the Climate Control is in Manual before turning the humidity level and tube temp to...

Page 10: ...aims please contact the original seller and they will work with us on the proper warranty claim process 10 Contact Us We are proud to provide best in class customer service so please contact us with a...

Reviews: