Zonix FP4640 Series Owner'S Manual Download Page 2

Table of Contents

3

. .

 . 

. .

 . 

. .

 . 

. .

 . 

. .

 . 

. .

 . 

. .

 . 

. .

 . 

. .

 . 

. .

 . 

. .

 . 

. .

 . 

. .

 .  

s

n

o

it

c

u

rt

s

n

g

n

ik

c

a

p

n

U

Energy Effi cient Use of Ceiling Fans  . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Electrical and Structural Requirements. . . . . . . . . . . . . . . . . . . . . . . . . .4

How to Assemble Your Ceiling Fan  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

How to Hang Your Ceiling Fan  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

How to Wire Your Ceiling Fan  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Installing the Canopy Housing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Mounting the Fan Blades and Cover Switch Assembly. . . . . . . . . . . . . 8

Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Blade Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Exploded-View Illustration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Trouble Shooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

1.   LIMITED LIFETIME MOTOR WARRANTY - If any part of your fan motor fails, due to a defect in materials or workmanship during 

the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned 

to our national service center.  Proof of purchase is required.  Customer shall be responsible for all costs incurred in the removal or 

reinstallation and shipping of the product for repairs or replacement.

2.   ONE YEAR MOTOR LABOR WARRANTY - If your fan motor fails at any time within one year from the original purchase, due to 

defects in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center.  Purchaser 

will be responsible for labor charges after this one-year period.  Customer shall be responsible for all costs incurred in the removal or 

reinstallation and shipping of the product for repairs or replacement.

3.   If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or workmanship, we 

will repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center.

4.   Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting, corroding, 

tarnishing, or peeling.

5.  This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to extremes of 

heat or humidity, or as a result of any modification to the original product.

6.   All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan 

or Fanimation.

7.   Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty.

8.   Under no circumstances may a fan be returned without prior authorization from Fanimation.  The receipt of purchase must ac-

company authorized returns and must be sent freight prepaid to Fanimation.  The fan to be returned must be properly packed to avoid 

damage in transit; Fanimation will not be responsible for any damage resulting from improper packaging.

9.   It is understood that any repair or replacement is the exclusive remedy available from Fanimation.  There is no other expressed or 

implied warranty.  Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and 

fitness for a particular purpose to the extent permitted by law.  Some states do not allow limitations on implied warranties.  Fanimation 

will not be liable for incidental, consequential, or special damages arising out of or in conjunction with product use or performance, 

except as may otherwise be accorded by law.  This warranty gives you special legal rights and you may also have other rights that vary 

from state to state.

10. A certain amount of wobble is normal and should not be considered a problem or a defect.

LIMITED LIFETIME WARRANTY

Extends to the original purchaser of a Fanimation Fan

Important Safety Instructions

WARNING: To avoid fire, shock and serious personal injury, follow these instructions.

1.   Read your owner’s manual and safety information before installing your new fan.  Review the accompanying assembly diagrams.

2.   Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power 

from being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a warning device, such 

as a tag, to the service panel.

3.   Be careful of the fan and blades when cleaning, painting, or working near the fan.  Always turn off the power to the ceiling fan before 

servicing.

4.   Do not insert anything into the fan blades while the fan is operating.

5.   Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions

1.   To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.   All wiring and installation procedures must satisfy National Electrical Codes (ANSI/ NFPA 70-1999) and Local Codes.  The ceiling fan 

must be grounded as a precaution against possible electrical shock.  Electrical installation should be made or approved by a licensed 

electrician.

3.   The fan base must be securely mounted and capable of reliably supporting at least 50 lbs. (fan and accessories not to exceed 50 lbs. 

or 22.7 kgs.).  See page 4 of owner’s manual for support requirements.  Consult a qualified electrician if in doubt.

4.   The fan must be mounted with the fan blades at least 2.3 meter from the floor to prevent accidental contact with the fan blades.

5.   Follow the recommended instructions for the proper method of wiring your ceiling fan.  If you do not have adequate electrical 

knowledge or experience, have your fan installed by licensed electrician.

6.   Suitable for use with solid-state speed controls.

WARNING:

  To Reduce The Risk Of Electrical Shock, This Fan Must Be Installed With A General Use, Isolating Wall Control/Switch.

WARNING:

  This product is designed to use only those parts supplied with this product and/or accessories designated specifically for 

use with this product.  Using parts and/or accessories not designated for use with this product could result in personal injury or property 

damage.

WARNING:

  To reduce the risk of personal injury, do not bend the blade bracket (flange or blade holder) when installing the brackets, 

balancing the blades, or cleaning the fan.  Do not insert foreign objects in between rotating fan blades.

WARNING:

  The building installation must contain a device to disconnect all poles of the fan from the main supply.  The contact distance  

in all poles must be 3mm minimum.

6.   Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.

7.   Contact your local government for information regarding the collection systems available.

8.   If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the 

food chain, damaging your health and well-being.

9.   When replacing old appliances with new once, the retailer is legally obligated to take back your old applicance for disposal at least

for free of charge.

10.   This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack

of experience and knowledge, unless they have given supervision or instruction concerning use of the appliance by a person responsible

for their safety. 

11.   Children should be supervised to ensure that they do not play with the applicance. 

Summary of Contents for FP4640 Series

Page 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP4640 220 The Zonix Wet Location Ceiling Fan Net Weight 6 7 kg 14 7 lbs...

Page 2: ...e original purchaser of a Fanimation Fan Important Safety Instructions WARNING To avoid fire shock and serious personal injury follow these instructions 1 Read your owner s manual and safety informati...

Page 3: ...ling Cover Switch Cup Cover Assembly Blade Set One Phillips head screwdriver One stepladder One blade screwdriver One wire stripper Three wire connectors supplied Hardware bags 3 16 24 x 13 mm blade t...

Page 4: ...doubt Electrical and Structural Requirements Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here ar...

Page 5: ...e to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properl...

Page 6: ...r shock be sure electricity is turned off at the main fuse box before hanging Figure 7 Figure 8 CEILING FLOOR Figure 10 Figure 9 Figure 7 MAIN FUSE BOX Outlet Box Hanger Bracket Screw 2 Supplied with...

Page 7: ...ould result 2 Securely connect the blue fan motor wire to the blue supply neutral wire using wire connector supplied Securely connect the brown fan motor wire and orange wire to the live supply normal...

Page 8: ...tating blades 1 Securely fasten the three blades with phillips head Figure 14 Figure 15 Support Cover Switch Cup Blade Screws screws with flat washers Figure 14 Phillips Head Screw with Flat Washer 3...

Page 9: ...should be avoided to prevent damage to finish CAUTION Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of electrical shock Blade Clean...

Page 10: ...3 AP464005 9 Hardware Bag Containing HDWFP4640 Blade Balance Kit BALKT Wire Connectors 4 Chain Coupler Chain Fob Blade Mounting Hardware Bag Containing 3 16 24 x 13 mm Pillips Head Screw 10 Flat Washe...

Page 11: ...e Zonix Model FP4640 220 Exploded View NOTE The illustration shown is not to scale or its actual con guration may vary Product parts are subject to change without notice Figure 1 9 6 5 1 3 4 2 7 8 9 1...

Page 12: ...not recommended choose an alternative control method 6 Tighten screws securely 7 Tighten set screw securely 1 Blades not attached to fan 2 Loose screws in motor housing 3 Screws securing fan blade ho...

Page 13: ......

Page 14: ...Copyright 2013 Fanimation 2013 07 V 01 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Page 15: ...The Zonix Ventilador de techo para ubicaciones h medas Peso neto 14 7 lbs 6 7 kg Modelo N FP4640 220 MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES Versi n...

Page 16: ...el ctricas este ventilador se debe instalar con un control interruptor de pared aislado ADVERTENCIA Este producto est dise ado para ser usado s lo con las piezas suministradas o los accesorios indica...

Page 17: ...calera de tijera Destornillador de Pelacables Tres conectores de cables incluidos Este manual est dise ado para facilitar al m ximo el ensamblaje la instalaci n el funcionamiento y el mantenimiento de...

Page 18: ...y haga funcionar el ventilador de techo a velocidad baja y en el sentido de las agujas del reloj Esto produce una suave corriente ascendente que obliga al aire c lido que se acumula cerca del techo a...

Page 19: ...o hacia arriba Figura 4 5 Vuelva a colocar la semiesfera en el barral como se indica a continuaci n Pase los tres cables de 80 a trav s de la semiesfera Pase el pasador a trav s de los dos orificios e...

Page 20: ...or y coloque el ensamble de la bola para colgar varilla en la abrazadera para colgar que acaba de fijar a la caja de salida Aseg rese de que la ranura de la bola est alineada con la leng eta de la abr...

Page 21: ...os en el motor N L1 L Suministro dom stico Caja de distribuci n el ctrica indicada Cable marr n con carga Cable ver amar tierra del soporte de suspensi n Cable ver amar tierra Cable azul neutro Figur...

Page 22: ...r No coloque objetos extra os entre las aspas del ventilador en funcionamiento ADVERTENCIA cabeza de phillips con arandelas de plano Figura 14 Tornillos de aspa Figura 14 Tornillo con cabeza de philli...

Page 23: ...la limpieza use s lo un cepillo suave o un pa o sin pelusas para evitar rayar el acabado No se requieren agentes abrasivos de limpieza los mismos deben evitarse para prevenir da os en el acabado PREC...

Page 24: ...Phillips de 4 24 Lista de piezas Modelo N FP4640 220 N de Ref Descripci n Pieza N Bolsa de accesorios que contiene de flano 10 Antes de desechar los materiales de embalaje aseg rese de haber extra do...

Page 25: ...ix Modelo FP4640 220 Producto partes est n sujetas a cambios sin previo aviso Figura 1 Despiece NOTA la ilustraci n que se muestra no est hecha a escala y su con guraci n real puede variar 6 5 1 3 4 2...

Page 26: ...es de cables en la caja 4 del interruptor no produzcan ruido al rozar unos con otros o al rozar la pared interior de la caja del interruptor PRECAUCI N Aseg rese de que el suministro principal de elec...

Page 27: ......

Page 28: ...13 Fanimation 2013 07 V 01 10983 Bennett Parkway Zionsville IN 46077 Llame Sin Cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fan...

Reviews: