General Installation Features
Registry Settings
The registry holds all configuration data for the ZSI-450-IP. To access the registry editor press “Start” and
then “Run”. At the prompt type “regedit” and press enter. The application will then launch.
Once the registry editor has loaded, navigate to the following key:
HKEY_CURRENT_USER\Software\Meyertech\VideoServer
This is the main registry key for the ZSI-450-IP settings, it has three sub keys. Each of these sub keys are
described below.
Communications
Inside the Communications key there are two values both of which are DWORD values. These are “Baud”
and “Port”.
The Baud value allows the user to specify the baud rate at which the selected port should operate. Valid
entries here are 9600, 19200 and 38400.
When entering these values be sure that the base for the
current data is set to decimal, this is set to hexadecimal by default and if a value was to be entered
this way it would result as an obscure value and the ZSI-450-IP would default to 9600 in this case.
The Port value allows the user to specify the number of the serial port to use.
DVRs
Inside the DVR’s key there are a variable amount of sub keys. Each of these sub keys has a number for the
name of the key. This number represents the remote site number that the values within that key represent.
So effectively this is where each of the sites supported by the ZSI-450-IP are to be configured. In the above
example these keys are listed as 1,2,3 and 4.
Within these keys are six values. These are
CONTROL_MODE, DVR_MODE, DVR_ADDRESS,
DVR_PORT, ZONEVU_ADDRESS
and
ZONEVU_PORT
.