Delete user
Delete the currently highlighted user
Login lockout
If enabled the operator gets 3 attempts to correctly login. If the operator fails then the
keyboard must be powered on for 10 minutes before another logon can be attempted.
Off
Edit user menu
Description
Default
Edit login name
Edit the new login name. 20 chars. max.
Access level
The access level of the new login - user, manager or engineer. A user can not
configure a user level higher than their own.
User
Priority
The priority level of the new login – 1 to 9
1
Password
The password for the user. Up to 20 chars, numbers, letters or symbols.
9999
LH Mode
Left Handed Mode – On/Off
See section ‘
Setting up Left Handed User Compatibility’
Off
•
User Interface Setup
Description
Default
Screen colour
The display colour. Either
black
screen with white text, or
white
screen with black
text.
White
Screen timeout
A screen timeout can be selected. If no user activity is detected then the screen will
blank after the specified number of seconds. Setting a time of 0 seconds disables
the screen timeout.
300 s
•
Custom Menu Setup
Custom menu setup is an option, which configures the look and feel of each operational menu by login level type ie
User, Manager or Engineer. This is a useful feature as it allows both the access and priority to be set by operator
type. See the
Softkeys
section of this document for the default configuration of the different modes.
Description
Default
Login level
Select the required operator level – user, manager or engineer
User
Insert new item
Insert a new command, at the point before the currently highlighted command
Insert macro
Insert a previously defined macro. The macro is appended at the end of the list
Move up
Move the highlight bar up through the command list.
Move down
Move the highlight bar down through the command list.
Delete item
Delete the currently highlighted command.
Revert to factory
setting
Reset the current menu to its default setting.
Each page of the menu can hold 9 commands. Blanks can be inserted instead of commands to assist in the
functional partitioning of the commands.
•
Misc. options
General configuration settings that can help tailor a keyboard to a specific installation.
Description
Default
Periph. Type
Early ZoneVu peripheral drivers used a different protocol. Select this only following advise
from Meyertech Technical Support
New
Nudge mode
Controls the operation of the nudge keys. These keys generate either zoom or focus
nudge commands. Can be set to either
Inverse J-stick
– nudge key opposite of joystick
twist action – or –
As J-stick
– nudge key same as joystick twist action.
Inverse J-stick
Spot monitor
The default monitor that the keyboard uses for camera switches. The keyboard will use
this monitor on power-up and if the
Select Monitor
Softkey is pressed followed by
Enter
(ie no monitor number selected).
1
Relay monitor
The monitor number used in the
Relay monitor
copy function.
1
Spot vcr
The VCR number which is used when the
Record
button is pressed (in all modes except
VCR mode).
1