background image

 

  

 

User’s 

Manual

 

It will continue to power the unit for about 1 hour after the “low battery” warning message and, in 
extreme cases, it can be charged even when the unit is in-use during a lesson. 
 
Ordinarily we recommend to charge the battery when not connected to the Saver One T. 
 
In case of long disuse period, we recommend to charge the battery at least once every 45 days in order to 
optimize its capability. 
 
Minimum number of charge cycles guaranteed: 300. 
 

 

Do not use or store in environmental conditions different from the given range 

Keep the battery away from heat and direct sunlight 

Do not store in places with dangerous concentration of flame gas or anesthetics 

Do not shock, cut, break or open the battery 

Keep the battery away from children 

If liquids came out from the battery and get in touch with eyes, wash them carefully with 

clean fresh water and consult immediately a doctor 

Dispose of exhaust batteries in respect with local laws 

 
 

CHARGER

 

The Saver One T is equipped with the SMART CHARGER (H01440010-XX-D1 Ni-MH/Ni-Cd) able to 
charge the battery. No other kind of charger is allowed to be used for charging the battery. 
 

Technical Specifications:

 

-Input Voltage from AC source: 100~240Vac, 50~60Hz, 30W 
-Output Voltage cigar jack: 2.4-14.4Vdc, 1000mA 
-Ambient operation temperature: 0°C to +40°C 
-Overvoltage and short circuit protections 
-Safety: CE compliant 
-LED Indicator: 1 bi-colored (red/green) 
 

Charging LED Control: 

 

Red and Green LED flashing for 2 times after connected 
to AC source, then both LED off 

 

Red LED on charging

 

 

Green LED on full charge

 

 

Red LED flashing on error status

 

 
To grant the perfect functionality and performance of batteries, here few recommendations for a good 
charging process: 
 

 

Before starting the charging process, be sure the charger or the battery are not overheated. Otherwise, 
wait for a few minutes so that both items reach room temperature which is the only condition to start 

Summary of Contents for Saver One T

Page 1: ...SAVER ONE SERIES the new generation User s Manual AED TRAINER www amiitalia com...

Page 2: ...User s Manual 2...

Page 3: ...ing unit helps students to become familiar with the use of the Saver One Semi Automatic AED in a real SCA Sudden Cardiac Arrest emergency event The Saver One T has clear voice instructions that provid...

Page 4: ...ent CPR 4 ON OFF switch 10 Hands off 5 Red LED for low battery status 11 Green LED for stand by unit status 6 Handle 12 Speaker Physical Size WxDxH 21 5 x 26 5 x 7 5 cm Weight 1 10 kg with battery Env...

Page 5: ...l 75 maximum concentration Do not clean it with other volatile material Use only damp non abrasive cloth for cleaning Do not let liquid such as water flow into the unit POWER SUPPLY The Saver One T is...

Page 6: ...r and consult immediately a doctor Dispose of exhaust batteries in respect with local laws CHARGER The Saver One T is equipped with the SMART CHARGER H01440010 XX D1 Ni MH Ni Cd able to charge the bat...

Page 7: ...k into the battery s DC connector and check that the LED on the charger turns red For empty batteries wait for the battery charging process will last at least 2 hours the charger s LED will remain lig...

Page 8: ...nguages Play scenario Pause scenario Lower volume Higher volume SINGLE EVENT SIMULATION BUTTONS Pads connection Shockable rhythm No shockable rhythm CPR Faulty unit Service required Low battery status...

Page 9: ...the unit This message is not broadcasted if pads are connected before turning on the unit This message will be repeated for five 5 times after which the unit is turning off by itself along with a bee...

Page 10: ...seconds the unit will pass to CPR step along with the voice message shock cancelled shock button not pressed S2 button scenario 2 ADULT Operations i no shock advised ii 2 minutes of CPR 30 2 ratio Me...

Page 11: ...n now make 5 cycles of 30 chest compressions followed by 2 breaths press patient s chest down fast metronome 30 beeps give two breaths breath 1sec mute breath if the shock button is not pressed within...

Page 12: ...ycles of 15 2 ratio Messages pediatric mode do not touch patient analysing heart rhythm shockable rhythm detected stay clear of patient charging press the shock button shock delivered it is safe to to...

Page 13: ...k cancelled shock button not pressed S9 button scenario 9 ADULT Operations i shockable rhythm detection ii faulty device warnings red LED on Messages do not touch patient analysing heart rhythm shocka...

Page 14: ...User s Manual 14...

Reviews: