UNIT CONTROL LEDs

:  flashing 

red 

or 

green 

 

  fixed 

red  

STAND-BY 

(with battery connected) 

Unit ready for use. 

 

Warning indicator for the low battery real-status. 

The battery needs to be charged. 

 + 

 

OPERATING 

Unit operating. 

Lights OFF 

Event simulation for a faulty unit. 

 

Warning indicator for the low battery real-status along with 

the voice message: “

low battery

”. 

The battery needs to be charged. 

 

 

Maintenance  

After turning off the unit, make sure to pull out the pads connector from the unit.

 

Keep the unit clean. If the unit is dirty, use a soft damp cloth with water or neutral 
detergent to wipe softly. If necessary, clean or sterilize it with a cloth soaked in 
medical alcohol (75% maximum concentration). Do not clean it with other volatile 
material. Use only damp non-abrasive cloth for cleaning. 
Do not let liquid such as water flow into the unit. 

 

 
 

POWER SUPPLY

 

The Saver One T is equipped with a Ni-MH Rechargeable Battery (12V@2Ah). 
 

 

 
A long-lasting battery able to power the Saver One T in continuous operating for around 20 hours or 30 
days in stand-by mode. 

 

Do not use or store in environmental conditions different from the given range 

Keep the unit away from heat and direct sunlight 

Do not store in places submitted to strong temperature variations and heavy vibrations 

Do not store in places with dangerous concentration of flame gas or anesthetics 

Do not store in places submitted to high concentration of powder 

Do not cut or break or open the unit 

Dispose of the unit in respect with local laws 

DC connector 

to link up the 

charger’s cigar-jack 

Summary of Contents for Saver One T

Page 1: ...SAVER ONE SERIES the new generation User s Manual AED TRAINER www amiitalia com...

Page 2: ...User s Manual 2...

Page 3: ...ing unit helps students to become familiar with the use of the Saver One Semi Automatic AED in a real SCA Sudden Cardiac Arrest emergency event The Saver One T has clear voice instructions that provid...

Page 4: ...ent CPR 4 ON OFF switch 10 Hands off 5 Red LED for low battery status 11 Green LED for stand by unit status 6 Handle 12 Speaker Physical Size WxDxH 21 5 x 26 5 x 7 5 cm Weight 1 10 kg with battery Env...

Page 5: ...l 75 maximum concentration Do not clean it with other volatile material Use only damp non abrasive cloth for cleaning Do not let liquid such as water flow into the unit POWER SUPPLY The Saver One T is...

Page 6: ...r and consult immediately a doctor Dispose of exhaust batteries in respect with local laws CHARGER The Saver One T is equipped with the SMART CHARGER H01440010 XX D1 Ni MH Ni Cd able to charge the bat...

Page 7: ...k into the battery s DC connector and check that the LED on the charger turns red For empty batteries wait for the battery charging process will last at least 2 hours the charger s LED will remain lig...

Page 8: ...nguages Play scenario Pause scenario Lower volume Higher volume SINGLE EVENT SIMULATION BUTTONS Pads connection Shockable rhythm No shockable rhythm CPR Faulty unit Service required Low battery status...

Page 9: ...the unit This message is not broadcasted if pads are connected before turning on the unit This message will be repeated for five 5 times after which the unit is turning off by itself along with a bee...

Page 10: ...seconds the unit will pass to CPR step along with the voice message shock cancelled shock button not pressed S2 button scenario 2 ADULT Operations i no shock advised ii 2 minutes of CPR 30 2 ratio Me...

Page 11: ...n now make 5 cycles of 30 chest compressions followed by 2 breaths press patient s chest down fast metronome 30 beeps give two breaths breath 1sec mute breath if the shock button is not pressed within...

Page 12: ...ycles of 15 2 ratio Messages pediatric mode do not touch patient analysing heart rhythm shockable rhythm detected stay clear of patient charging press the shock button shock delivered it is safe to to...

Page 13: ...k cancelled shock button not pressed S9 button scenario 9 ADULT Operations i shockable rhythm detection ii faulty device warnings red LED on Messages do not touch patient analysing heart rhythm shocka...

Page 14: ...User s Manual 14...

Reviews: