Zon 4MT08

        Pressure regulator (Shell type)            Precise regulator

5  Screw the hose fracture protection valve onto the pressure regulator (on is 

counterclockwise). Secure a no-leak connection by using Loctite or teflon 

tape on the wire of the hose fracture protection valve. The precise regulator 

only allows a small amount of gas flowing through in a relatively long pe-

riod. To produce a series of shots, it’s necessary to allow a large amount of 

gas in a short period, that’s why the precise regulator has to be disconnec-

ted. The hose fracture protection valve provides extra security, by closing the 

gas flow at the moment the counter-pressure disappears. For instance when 

the hose detaches on either side of the equipment, or when it is accidentally 

run over and severely damaged. 

After opening the valve of the gas 

tank always push the red button of the hose fracture protection 

valve, to make sure an unobstructed gas flow is guaranteed.

             Pressure regulator                Hose fracture protection valve

Summary of Contents for DAZON 4MT08

Page 1: ...1 Zon 4MT08 Zon 4MT08 User Manual DAZON bv ...

Page 2: ...t selects a different time interval after each series The control unit is equipped with a 24 hours clock No less than 4 periods can be configured during which the control unit will operate the propane gas cannon Always wear ear protection near cannons in operation 1 Contents of the conversion kit 1 MT08 electronic control unit 1x 2 SBBV hose fracture protection valve 1x 3 NH14 hose clamp 3x 4 User...

Page 3: ... shots it s necessary to allow a large amount of gas in a short period that s why the precise regulator has to be disconnec ted The hose fracture protection valve provides extra security by closing the gas flow at the moment the counter pressure disappears For instance when the hose detaches on either side of the equipment or when it is accidentally run over and severely damaged After opening the ...

Page 4: ...e should be attached to the of the battery The blue wire should be attached to the When attached properly a red control will light up to show the device is active Check the connections when this does not happen The control unit consumes 0 53 ampere per day A fully loaded car battery of 30Ah will operate the control unit for approximately 60 days a 7 2 Ah battery for approximately 14 days 11 Positi...

Page 5: ...en it is pushed fully to the side of the red block with the numbers 1 through 6 on it In above example dipswitches 2 and 5 are ON the others are OFF With this configuration there are 3 shots in a series and 7 minutes between series These are our factory settings The current time and the periods during which the control unit should operate the propane gas cannon can be configured with the 5 figure ...

Page 6: ...6 Dazon bv Hours Minutes Mode 5 figure display with 4 push buttons Pushbutton Hours Pushbutton Minutes Pushbutton Mode Pushbutton Reset Setting hours Setting minutes Selecting Mode Reset ...

Page 7: ...non and let it produce 1 2 3 or 4 shots in a series with approximately 5 seconds between each shot The number of shots in a series is controlled with dipswitch 1 and 2 Series Dipswitch 1 Dipswitch 2 1 shot Off Off 2 shots On Off 3 shots Off On 4 shots On On ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ...

Page 8: ... Off On Off Off 5 minutes On On Off Off 7 minutes Off Off On Off 10 minutes On Off On Off 13 minutes Off On On Off 16 minutes On On On Off 20 minutes Off Off Off On 25 minutes On Off Off On 30 minutes Off On Off On 45 minutes On On Off On 60 minutes Off Off On On ON DIP 1 2 3 4 5 6 ON ON DIP 1 2 3 4 5 6 DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON ON ON ON ON ON ON ON ON DIP 1 2 3 4 5 6 DIP 1 2 3 4 5 6 D...

Page 9: ...ime after a shots series is randomly chosen by the control unit between 1 and 5 minutes Random 10 the time after a shots series is randomly chosen by the control unit between 1 and 10 minutes Random 15 the time after a shots series is randomly chosen by the control unit between 1 and 15 minutes ON ON ON DIP 1 2 3 4 5 6 DIP 1 2 3 4 5 6 DIP 1 2 3 4 5 6 ...

Page 10: ...ontain the value 99 The current time is a continuously changing value that can t be stored into memory After each power interruption the current time will contain 99 99 When no current time is set the control unit will operate the gas cannon continuously regardless of the periods of operation being set Hours Minutes Mode Hours Minutes Mode No current time set The current time is 12 44 hr By pushin...

Page 11: ...t to set or change has to be displayed Push the Mode button repeatedly until the value in the Mode display is the one belonging to the time you want to modify Mode 1 Starting time period 1 Mode 2 Ending time period 1 Mode 3 Starting time period 2 Mode 4 Ending time period 2 Mode 5 Starting time period 3 Mode 6 Ending time period 3 Mode 7 Starting time period 4 Mode 8 Ending time period 4 Hours Min...

Page 12: ...hanging of hours or minutes By pushing the reset button for 1 second the shown time will be set to 00 00 this is 12 o clock at midnight If the time is set it has to be activated and written to memory by pushing the Mode button again After a power interruption the value will still be intact Not all 4 periods have to be set you only have to set the ones you want In case no period is set all starting...

Page 13: ...ill light during the time gas is injected into the cannon The led with the character B beside it will light when the control unit activates the electronic ignition this ignition will only be used on the Zon EL08 Be careful the explosion will follow in less then 2 seconds Led V open gas valve Led B ignition When the control unit is powered on and the display is not lit pushing the reset button shor...

Page 14: ... like a wired or wireless remote control When equipment is con nected to the and of this input and short circuits these the control unit will immediately begin to operate the gas cannon and let it produce the configu red number of shots regardless of the periods of operation being set In case the control unit should operate the gas cannon only on commands received through the extra IN input it is ...

Page 15: ...h button is connected to the extra IN input Pushing the button will activate the control unit immediately and let it generate a series of shots When finished it will automatically switch back to the confi gured program Zon 4MT08 15 ...

Page 16: ...16 Dazon bv DAZON bv P O Box 5502 Bergerstraat 35 6202 XA Maastricht 6226 BA Maastricht The Netherlands The Netherlands T 31 0 43 362 08 76 E info dazonbv eu F 31 0 43 363 53 73 w www dazonbv eu ...