CHARGING THE BATTERY PACK
Charge the battery pack only with the charger provided.
Allow at least 75 minutes of charge time for 2Ah battery or 120
minutes of charge time for 4Ah battery before initial use of the blower.
Make sure the power supply is normal household voltage, 120volts,
60Hz, AC only.
The battery charger should be operated in temperatures between 32
and 100 degrees F
The battery should be charged in a cool, dry place.
2 to 3 initial charging/discharging cycles may be required to achieve
maximum run time/capacity.
DO NOT attempt to open the charger or the battery. There are no
customer serviceable parts inside. Call customer service helpline at
1-800-313-5111 for assistance.
DO NOT incinerate battery packs even if they are severely damaged
or completely worn out. They can explode in a fire causing injury.
DO NOT charge appliance in rain, or in wet locations.
Use the battery charger indoors only.
Disconnect charger from the power supply when not in use to prevent
damage to the charger during a power surge.
When fully charged, the battery can be safely stored in temperatures
down to - 4 degrees F for a period of up to four weeks, before
requiring charging. Fully charge battery pack every 90 days.
If over a period of time the battery pack quickly runs down after a
75min or 120min full charging period, a replacement battery pack is
needed.
To prevent permanent damage to the battery, never store in a
discharged condition.
WINTER STORAGE - Fully recharge before storage and then again
every 90 days.
Since the battery will not develop a memory, it does not have to be
fully discharged before recharging.
A small leakage of liquid from the battery cells may occur under
extreme usage, charging or temperature conditions. This does not
indicate a failure. However, if the outer seal is broken and this
leakage gets on your skin.
a. Wash quickly with soap and water.
b. Neutralize with a mild acid such as lemon juice of vinegar.
c. If the battery liquid gets in your eyes, flush them with clean
water for a minimum of 10 minutes and seek immediate
medical attention.
TO CHARGE - SEE CHARGER MANUAL FOR COMPLETE INSTRUCTIONS
INSTALLING AND REMOVING BATTERY PACK FROM THE UNIT
Slide the battery pack in your blower (see Fig. 4). Ensure the battery
is securely connected to blower. To remove battery, depress release
button and slide battery pack out of tool.
BATTERY DISPOSAL
Remove the battery pack from the Cordless Blower, cover the terminals with heavy duty adhesive tape. Do not attempt to destroy
or disassemble battery pack or remove any components. This product contains lithium-ion batteries which must be recycled or
disposed of properly. Local, state or federal laws may prohibit disposal of these batteries in the municipal solid waste or rural trash
pick up systems.
The RBRC seal on the Li-Ion battery pack indicates that the cost to recycle the battery pack at the end of its useful life has already
been paid by The Great States Corporation/American Lawn Mower Company. It is illegal to place spent Li-Ion batteries in the local
municipal solid waste or in the trash. RBRC in cooperation with The Great States Corporation/American Lawn Mower Company has
provided an environmentally friendly and easy way to recycle spent Li-Ion batteries. Just contact your local recycling center or call
1.800.8.BATTERY for information on where to drop off the spent battery.
Constant Red + Flash Green = Battery is charging
Constant Red + Constant Green = Battery is fully charged
Battery Pack
5
Fig. 4
Battery release
button
Fig. 3
Charger