7
6
PARTS NAMES AND FUNCTIONS
Cont.
Press in the Lid Lock as illustrated.
Press down the Upper Lid.
Pull the Lid Lock up with fingers
to open the Upper Lid.
To Open
To Close
●
Press down firmly until the both Lid
Locks clicks.
If the orange colored line can be seen at the inside or outside of the Lid Lock, it indicates
the Upper Lid is not closed securely. If this happens, be sure to press the Upper Lid
down securely.
●
Please be sure that the Upper Lid is securely closed.
(Not doing so may cause the hot water to leak and resulting in scalding.)
1
1
2
The orange
colored line is
seen at inside.
The orange
colored line is
seen at outside.
Be careful not to tip the product over.
When opening and closing the Upper Lid, please be sure to remove the
Body from the Power Base.
1
2
The first time you use the product or after storing it for a long period of
time, boil water once and discard it before boiling water for consumption.
Only use the coordinated
Power Base designed for
this product.
When mineral water or alkalized ionic water are used,
a floating residue may develop or a milky white
substance may form on the surface of the Inner
Container.This is due to the ingredients in the water
and is harmless to your health.
When using mineral water or alkalized ionic water,
please perform cleaning and maintenance frequently.
●
When using mineral
water or alkalized ionic water:
Fill the Inner Container
with water before
placing the Body onto
the Power Base.
Close the Upper Lid securely.
Place the Body onto the
Power Base.
1
2
BOIL MODE
How to Open/Close the Upper Lid
①
②
Open the Upper Lid and fill the Inner Container
with water using a pitcher or other container.
The first time
you use the product you
may notice the smell of
plastic. This is normal
and will gradually fade
away.
●
Do not fill the Inner Container directly from a water faucet or
place the product on a wet surface such as a sink. (Exposing
the heating element directly to water may cause malfunction.)
●
Avoid splashing water on the Body and Control Panel. (May
cause malfunction.)
●
Do not fill over the Maximum Water Level Line. (Hot water
may overflow from the Steam Vent or Spout.)
●
Do not fill the Inner Container with any liquid other than
water.
●
Do not use water additives such as charcoal for water
purification or mineral additives. (Small particles may get
clogged inside of the product.)
●
Be sure to close the Upper Lid securely. If the Upper Lid is
not closed securely, the power will not switch OFF when
boiling completes.
●
Do not fill the Inner Container while the Body is connected to
the Power Base. (Doing so may splash water on the Power
Base and cause malfunction.)
NOTE
Close the Upper Lid and place the Body on the Power
Base.
Set the Body on the Power Base
correctly so that the Connector fits
in the Receptacle securely.
Press the Upper Lid down securely
until it clicks.
Otherwise hot water may spill out
from gaps other than the Spout
when pouring, resulting in scalds.
Receptacle
Connector
Place the Power
Base on a clean,
level and stable
surface.
NOTE
NOTE
Maximum
Water Level
Line
Please be careful with
the steam coming out
when opening and
closing the Upper Lid.
Do not open the
Upper Lid while
boiling or immediately
after boiling
completion. Doing so
may cause scalding.