Typical Outdoor Grinder Pumping System Installation

All installations must comply with all applicable electrical and plumbing codes, including but not limited to the 

National Electrical Code, local, regional and/or state plumbing codes, etc.

FIGURE 3.

R

LOUISVILLE, KY

SILENCE

INPUT 1

POWER

4" PIPE SEAL

(FIELD INSTALLED)

2" PIPE SEAL

(FIELD INSTALLED)

24" MIN.

FIBERGLASS AFD

1.25-2" Z-RAIL

2" CAST IRON CHECK VALVE

3/4" GUIDE RAILS

2" SCH. 80 BALL VALVE

2" FLEX BOOT FITTING 

(LOCATION VARIES 

WITH BASIN DEPTH)

FLOAT TREE ASSEMBLY

2HP GRINDER PUMP

2" PVC SCH. 80 PLBG.

1/8" 302 STAINLESS STEEL 

LIFTING CABLE

ALARM

ON
OFF

SOLID FIBERGLASS COVER

HIGH WATER ALARM 

OR SIMPLEX 

CONTROL PANEL 

(FIELD INSTALLED)

ALARM FLOAT SWITCH MUST OPERATE OFF LOW 

VOLTAGE TO BE USED WITH QWIK BOX.

SK3110

FOAM TAPE

UL LISTED

EPOXY SEALER

  #10-2350 POTTING KIT

 APPLIES TO INSIDE AND

OUTSIDE INSTALLATIONS

CONDUIT

1

WIRES OR

PUMP CABLES

1/4" TO 1/2"

(25 mm)

(6 mm TO 12 mm)

SK1661

LOCATION VARIES WITH BASIN DEPTH

Summary of Contents for SHARK 800 Series

Page 1: ...ble of Contents Safety Instructions 1 Limited Warranty 2 Preinstallation Checklist 3 General Information 4 Pump Wiring Instructions 5 Typical Indoor Prepackaged System 6 Indoor Prepackaged Installatio...

Page 2: ...e mechanism or the complete unit No allowance will be made for shipping charges damages labor or other charges that may occur due to product failure repair or replacement This warranty does not apply...

Page 3: ...iarities and are secured so that the grinder pump will shut off It is recommended to use rigid pipe and fittings and the pit be 24 in diameter for simplex systems and 36 in diameter for duplex systems...

Page 4: ...t comply with the National Electrical Code and applicable local codes Conduit and panel enclosure openings must have a gas and watertight seal Installation of electrical panels conduit and connections...

Page 5: ...diagram above to secure the float switch properly and obtain the proper tether to customize the on off cycle to each application Note the minimum off level shown above On Prepackaged Systems the tethe...

Page 6: ...STEEL CORD SEAL INSPECTION PLATE 3 GROMMET SEAL SWITCH CORD ALARM FLOAT BASIN COVER LIFTING BOLT 16 X 1 4 STEEL 5 16 304 STAINLESS STEEL PUMP PLATE PUMP POWER CORD SILENCE INPUT 1 POWER ON FIELD INST...

Page 7: ...be located in a very low traffic area within 15 of the power disconnect The hole should be at least 8 larger in diameter than the basin in order to leave 4 of backfill all the way around the perimete...

Page 8: ...LASS AFD 1 25 2 Z RAIL 2 CAST IRON CHECK VALVE 3 4 GUIDE RAILS 2 SCH 80 BALL VALVE 2 FLEX BOOT FITTING LOCATION VARIES WITH BASIN DEPTH FLOAT TREE ASSEMBLY 2HP GRINDER PUMP 2 PVC SCH 80 PLBG 1 8 302 S...

Page 9: ...inner diameter with the hole in the basin Attach the hub to the side of the basin using the sealant and hardware provided 6 The bottom of the excavation can now be properly backfilled compacted and le...

Page 10: ...ely installed Floats positioned properly Discharge valves open 3 16 vent hole drilled in pipe between check valve and pump Once the above has been verified proceed with the following checks Pump power...

Page 11: ...ng both disc and cutter to a 32 micro finish Do not attempt grinding in the field Send parts to a qualified machine shop or return to the factory for repair The disc cutter and shims are a matched set...

Page 12: ...ays disconnect pump and panel from its power source before handling Never enter the basin until it has been properly ventedandtested Anypersonenteringabasinshouldbewearing aharnesswithsafetyropeextend...

Reviews: