background image

2.  Check to be sure your power source is adequate to handle the amperage 

requirements of the motor as indicated on the pump or unit I.D. tag. 

4.  Maximum operating temperature must not exceed 40 °C (104 °F). 

 

5.  Do not use cleaning products containing bleach in the toilet tank, toilet or

attached 

as they will degrade the pump seals.

SEE BELOW FOR LIST OF CAUTIONS

3.  All plumbing (discharge and carbon filter

  vent) must

  be

  installed

  to meet

local codes. Unit must be vented. Do not use an automatic plumbing 

vent 

6. This product is designed for use with one toilet only.

 

1.  Repair and service should be performed by an Authorized Service and 

Warrenty Center only. (Consult Factory.)

4.  All

 connecting to the system must be on the same 

level.

SEE BELOW FOR LIST OF NOTES

NOTES

2.

3.  Pumps with the “cCSAus”

 

mark

Pumps with the “cCSAus” mark

 

and/or the

 

“US”

 

mark

 

are

 

tested to UL

 

Standard

UL778. 

are

 

to CSA Standard

C22.2 No.108.

LIMITED WARRANTY

HELPFUL HINTS FOR EASY INSTALLATION

DO’S AND DON'T’S,

 continued

DO’S AND DON'T’S FOR INSTALLING A UNIT

1.  DO read all installation material with the unit.

2.  DO inspect unit for any visible damage caused by shipping. 

     Contact dealer if unit appears to be damaged.

3.  DO clean all visible debris from the unit.

4.  DO always disconnect pump from power source before handling.

     DO always connect to a separately protected and properly grounded

     ground fault protected circuit. DO NOT ever cut, splice or damage

     power cord. DO NOT carry or lift pump by its power cord. DO NOT

     use an extension cord.

5.  DO install a ball or gate valve and a union in the discharge line

     downstream of the check valve.

6.  DO test pump immediately after installation to be sure that the system

     is working properly.

7.  DO review all applicable local and national codes and verify that the

     installation conforms to each of them.

8.  We DO NOT recommend this product be connected to utilities other than

     those found in a normal bathroom application. Washing machines and

     dishwashers are examples of equipment that we DO NOT recommend.

9.  DO inspect and test system for proper operations at least every 3 months.

1.  Read all instructions before beginning installation.

2.  Be sure the floor is level within 3 mm (1/8").

3.  Install vent pipe seal with flange side of seal on the outside of lid.

4.  Use soapy water to lubricate all seals to aid installation.

5.  Install rubber coupling/union in vent line to aid disassembly.

6.  Do not over torque toilet mounting screws.

7.  Do not use an automatic plumbing vent device.

8.  Obtain model number and date code, and record information in the

     space provided on the front of this manual. Refer to this information

     when calling the factory.

7. Conductor color coding: Type 1 - Line (Brown), Neutral (Blue), Ground

(Yellow / Green). Type 2 - Line (Black), Neutral (White), Ground (Green). 

8. Electrical control box or electrical box are waterproof required.

9. Prop65 Warning for California residents: Cancer and Reproductive Harm-

www.P65Warnings.ca.gov.

In those instances where damages are incurred as a result of an alleged pump failure, 

the Homeowner must retain possession of the pump for investigation purposes.

1.

NOTE: Consult Factory if installation is above 20' (6.1 m) vertical height in 1" 

(DN25). The macerator pump is designed for use in Qwik Jon

®

 Choice units 

only. It is not designed for use in any other application.

-  2  - 

© Copyright 2022 Zoeller

®

 Co. All rights reserved.

Manufacturer warrants, to the purchaser and subsequent owner during 

the warranty period, every new product to be free from defects in materi-

al and workmanship under normal use and service, when properly used 

and maintained, for a period of one year from date of purchase by the 

end user, or 18 months from date of original manufacture of the product, 

whichever comes first. Proof of purchase is required. Parts that fail within 

the warranty period, one year from date of purchase by the end user, or 

18 months from the date of original manufacture of the product, whichev-

er comes first, that inspections determine to be defective in material or 

workmanship, will be repaired, replaced or remanufactured at Manufac-

turer's option, provided however, that by so doing we will not be obligat-

ed to replace an entire assembly, the entire mechanism or the complete 

unit. Fill and flush mechanism are guaranteed as per OEM warranty only 

and vitreous china are guaranteed only for a factory defect. No 

allowance will be made for shipping charges, damages, labor or other 

charges that may occur due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any 

material or product that has been disassembled without prior approval of 

Manufacturer, subjected to misuse, misapplication, neglect, alteration, 

accident or uncontrolled weather event; that has not been installed, 

operated or maintained in accordance with Manufacturer's installation 

instructions; that has been exposed to outside substances including but 

not limited to the following: sand, gravel, cement, mud tar, hydrocar-

bons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other 

abrasive or corrosive substances, wash towels or any other abusive 

entity, etc. in all pumping applications. The warranty set out in the 

paragraph above is in lieu of all other warranties expressed or implied; 

and we do not authorize any representative or other person to assume 

for us any other liability in connection with our products. 
Contact authorized distributors to obtain any needed repair or replacement 

of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR 

SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR 

BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND 

ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR 

PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED 

TO THE DURATION OF THE EXPRESSED WARRANTY. 
Some jurisdictions do not allow limitations on the duration of an implied 

warranty, so the above limitation may not apply to you. Some jurisdic-

tions do not allow the exclusion or limitation of incidental or consequen-

tial damages, so the above limitation or exclusion may not apply to you. 

This warranty gives you specific legal rights and you may also have 

other rights which vary from jurisdiction to jurisdiction.

This unit is not designed to handle any material other than human waste

and toilet paper. The list of items that should not be used with this system

includes, but is not limited to: feminine sanitary products, condoms, cotton

balls and swabs, baby wipes, paper towels, etc.

Summary of Contents for QWIK JON CHOICE 200

Page 1: ...ve power supply cord and strain relief or connect conduit directly to the pump If the supply cable is damaged it must be replaced by an authorized Zoeller Representative 9 Pump contains oil which becomes pressurized and hot when operating Allow 2 1 2 hours after disconnecting before attempting service p m u P 0 1 is not intended for potable water due to possible contamination by oil contained in t...

Page 2: ...above 20 6 1 m vertical height in 1 DN25 The macerator pump is designed for use in Qwik Jon Choice units only It is not designed for use in any other application 2 Copyright 2022 Zoeller Co All rights reserved Manufacturer warrants to the purchaser and subsequent owner during the warranty period every new product to be free from defects in materi al and workmanship under normal use and service whe...

Page 3: ...09 Outlet Pipe Assembly Repair Kit 084839 Check Valve Assembly Repair Kit 084854 Decorative Cover of the Pump Repair Kit 084855 Decorative Cover of the Junction Box Repair Kit 085179 Pump Repair Cover Repair Kit 084846 Tank Cover Repair Kit 084847 Filter Basket and Inlet Elbow Pipe Repair Kit 084848 Cutter Set Repair Kit 084844 Pump Discharge Elbow Pipe and Volute Repair Kit 084849 Volute Discharg...

Page 4: ...discharge pipe Remove pipe and flush out debris Low or incorrect voltage Have a qualified electrician check house wiring Damaged Impeller Contact a Zoeller Authorized Service and Warrenty Center Incorrect float adjustment Contact Product Support Department Pump is air locked Make sure vent hole in discharge pipe is clear Vertical lift too high C PUMP OPERATES BUT DELIVERS LITTLE OR NO WATER A PUMP...

Page 5: ...nstallation is to be used locate the pump unit in an area that will allow access to the pump and switch OUTLET WATER SUPPLY DISCHARGE PIPE VENT PIPE LEVEL FLOOR BALL OR GATE VALVE SOLD SEPARATELY SK2588 STEP 2 LEVELING OF PUMP UNIT carbonfiltervent The use of a mechanical vent system is NOT recommended as the toilet will not Please replace the carbon filter periodically Optional OPTIONAL CARBON FI...

Page 6: ...s later 4 Remove the toilet from the pump unit and set it aside STAND ALONE INSTALLATION BEHIND THE WALL INSTALLATION 1 Installing the pump unit behind a wall will require an extension kit P N 10 2123 sold separately 2 Placethetoiletassemblyaminimumof13 mm 1 2 from the wall and mark the closet bolt locations on the floor 3 Measure the appropriate length of 3 1 2 Schedule PVC 40 pipe provided with ...

Page 7: ...vent piping as required for proper venting Proper venting is required Cut and the pipe and as required for 1 DN25 diameter discharge pipe may be reduced to 3 4 DN20 diameter Note Adding other bathroom The Qwik Jon Choice is designed to accept additional bathroom utilizing the two side inlets Available for connecting DN25 1 pipe Simply reverse the pipe adaptor dry fit fittings fixtures fixtures and...

Page 8: ...any tubing sizes Ensure the connections are according to local regional and state codes Connect the discharge pipe to the top of the Qwik Jon Choice These drawings are for reference only Exact components may differ by region 8 Copyright 2022 Zoeller Co All rights reserved These drawings are for reference only Exact components may differ by region ...

Page 9: ...e power cord into a wall socket to provide power to the unit carbon filter stack vent These drawings are for reference only Exact components may differ by region These drawings are for reference only Exact components may differ by region 9 Copyright 2022 Zoeller Co All rights reserved ...

Page 10: ...rawings are for reference only Exact components may differ by region These drawings are for reference only Exact components may differ by region 10 Copyright 2022 Zoeller Co All rights reserved Mechanical and Electrical Hazard Disconnect power prior to maintenance or opening This equipment is only to be serviced and maintained by a qualified professional WARNING ...

Page 11: ...w driver Open the macera ng basket by removing the protec ve lid These drawings are for reference only Exact components may differ by region These drawings are for reference only Exact components may differ by region 11 Copyright 2022 Zoeller Co All rights reserved ...

Page 12: ...cu ng system with sharp edges Do not reach into macera ng tank or basket injury can occur DANGER Use tools such as needle nose pliers to retrieve debris in the macera ng basket ACCESSING THE JUNCTION BOX Pry the decora ve cover open with a screw driver These drawings are for reference only Exact components may differ by region 12 Copyright 2022 Zoeller Co All rights reserved ...

Page 13: ...t switch The junc on box can be accessed to replace the capacitor or troubleshoot the system These drawings are for reference only Exact components may differ by region These drawings are for reference only Exact components may differ by region 13 Copyright 2022 Zoeller Co All rights reserved ...

Page 14: ...differ by region The junc on box can be further removed by unscrewing the top screws for access to the float switch sleeve and tank internal These drawings are for reference only Exact components may differ by region 14 Copyright 2022 Zoeller Co All rights reserved ...

Page 15: ...70 m 229 1 outside diameter Ø32 pipe max 137 m 449 3 4 outside diameter Ø25 pipe max 94 m 310 1 outside diameter Ø32 pipe max 189 m 621 3 4 outside diameter Ø25 pipe max 131 m 430 6 m 20 5 m 16 4 m 13 3 m 10 1 5 m 5 084825 TOTAL DYNAMIC HEAD FLOW Meters 1 5 MODEL Feet Liters min m3 hr 3 0 4 6 6 1 5 10 15 20 7 5 6 7 5 3 3 2 124 6 112 0 87 6 54 0 8 0m 26 25ft Shut off Head 220V 50Hz Pump Performance...

Page 16: ... the laws of the EC Member States rela ng to Electromagne c Compa bility 2014 30 EU Standards used EN 61000 3 2 EN 61000 3 3 and EN 55014 1 BS EN IEC 61000 3 2 BS EN IEC 61000 3 3 BS EN IEC 55014 1 Electrical equipment designed for use within certain voltage limits 2014 35 EU Standards used EN60335 1 and EN60335 2 41 Restric ve and Hazardous Substances RoHS Direc ve 2011 65 EU Waste Electrical and...

Reviews: