Zoeller ProPak AQUANOT FIT 508/63 Installation Instructions Manual Download Page 6

6

© Copyright 2022 Zoeller

®

 Co. All rights reserved.

SK3183

2

3

1

4

5

12

10

11

9

6

7

8

12 VOLT BATTERY

SUPPLIED BY USER

Model 508 Fit Service Parts

Item

Description

Qty

508-C

8/18

thru Current

1

Pump 12 V DC / Backup 

(service part)

1

155652

2

Flapper asm, (service 

part)

1

152970

3

Fitting & clamp "508" 

(service part)

1

152969

4

Fitting, PVC 1-1/2" 

(DN40) tee/SCH 40 

(pressure fitting)

1

153766

5

Valve, check / 1.5" 

(DN40) Inline / vertical

1

153772

6

Operational float, N.O.

1

155654

7

Clamp, #28 Worm-SS 

(for float switch)

2

004287

8

Fit controller

1

155368

9

Fuse, 30 amp  

automotive, blade-type

1

016918

10

High water float, N.C.

1

155653

11

Battery box asm (box 

and cover)

1

10-0764

12

Hardware pak, charger 

/switch mode

2

152864

13

Pump, M53/115V

1

53-0001

Pump, M63/115V

1

63-0001

Pump, M98/115V

1

98-0001

EXPLODED VIEW - DC PUMP SYSTEM SERVICE PARTS

AQUANOT

®

 FIT FLOAT SWITCH

FIGURE 3

SK3186

LOCKING PIN MUST BE

INSTALLED UNDER FLOAT

ROD IN THIS LOCATION.

MOLEX 2-PIN CONNECTOR

MOLEX 4-PIN CONNECTOR

FLOAT STATUS LED

DC PUMP LED

BATTERY LED

SYSTEM READY LED

Z CONTROL LED

GROUNDED POWER CORD

SILENCE BUTTON

TEST BUTTON

WHITE LEAD

(POSITIVE)

BLACK LEAD

(NEGATIVE)

30 AMP FUSE

DC PUMP

HIGH WATER

OPERATIONAL

SK3187

FIGURE 4

Note: Upper rubber stop is usually not needed.

Summary of Contents for ProPak AQUANOT FIT 508/63

Page 1: ...5 V outlet DO NOT USE AN EXTENSION CORD 2 Make sure the 115 V electrical supply circuit is equipped with fuses or circuit breakers of proper capacity 3 DC emergency pumps are designed for handling cle...

Page 2: ...state Discharge Feet of Head 5 1 5 m 10 3 m 15 4 6 m 28 85 m Flow GPM LPM 12 7 volts 43 163 35 132 27 102 Shut off Head This system is a combination of a primary sump pump and a backup pump to your pr...

Page 3: ...Install the Fit Controller see Figure 3 by using the anchors provided For best cooling install wall mount configuration The controller should be located at least 3 1 m above the sump 9 Connect the lea...

Page 4: ...controllerwillturnthepumponand off a few times before running the pump continuously This is to purge a suspected air lock If the high water float is removed unplugged the resulting controller and pump...

Page 5: ...DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT FIT CONTROLLER OUTLET CONTROLLER HI WATER REED SENSOR 1 1 2 SCH 40 PVC PIPE X 10 254 mm LG 1 1 2 SCH 40 PVC TEE NOTE CHECK VALVE SC...

Page 6: ...oller 1 155368 9 Fuse 30 amp automotive blade type 1 016918 10 High water float N C 1 155653 11 Battery box asm box and cover 1 10 0764 12 Hardware pak charger switch mode 2 152864 13 Pump M53 115V 1...

Page 7: ...ed Z Control Connected Searching Broadcasting SSID or Dormant Note will not persist if pump didn t pump water See also the laminated label affixed to the controller s cord This cord label also describ...

Page 8: ...oints Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 3 If fuse is blown replace with 30 amp automotive blade fuse e Remove pump Check f...

Page 9: ...rol Cloud will also be updated with the firmware update information and notification to email accounts will occur 5 You now should go back to the Z Control app to find your new device set up in the lo...

Page 10: ...ection to router is not successful If you need to force the Fit into AP mode again press the Z Control button for 12 seconds See Figure A This will cause the Fit to re enter AP mode and begin transmit...

Page 11: ...ng installed After up to 1 minute the Fit will restart and return to normal operation The Fit s alert history on the Z Control Cloud will also be updated with the firmware upgrade information and nofi...

Page 12: ...s by products capable of causing the CO detector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year...

Reviews: