background image

11

© Copyright 2022 Zoeller

®

 Co. All rights reserved.

4.   Once the Fit’s Z Control

®

 LED is solid, log in to your account (or create one) at zcontrolcloud.com. Choose the Add New Device button 

next to the location you want to use for the Fit (see Figure D). Follow the directions to add your Fit by either auto-detect or entering the 

Device I.D. When successful, a Fit product tile will appear in your account.

Firmware Updates: 

The Fit is capable of OTA, or “over the air” firmware updates. It’s possible that the Fit could perform an update immediately if one is available at 

the Z Control

®

 Cloud. If an update is taking place, the Z Control

®

 LED will flicker for up to 1 minute while the update is downloaded. The Z Control

® 

LED will be solid and all other LEDs will turn off while the update is being installed. After up to 1 minute, the Fit will restart and return to normal 

operation. The Fit’s alert history on the Z Control

®

 Cloud will also be updated with the firmware upgrade information, and nofication to email 

accounts will occur.

When you add the correct 

Device ID, a Fit product tile 

will appear in your account

Select Add New Device

Figure D

Congratulations! Your Fit is online. Be sure you have added the contact information for phone numbers and email adresses that should receive 

notifications. This can done by selecting "Manage Contacts" from the main menu (the square with 3 lines in the upper right corner). You can also 

edit how each device sends out notifications from the device's "Alarm Settings" tab. You can now open the product’s configuration by clicking the 

“View” button to modify the Fit’s device and notification settings. You can also install the Z Control

®

 mobile app on your mobile device (Android and 

iOS versions available, search “Z Control

®

” in the app stores).  

Summary of Contents for ProPak AQUANOT FIT 508/63

Page 1: ...5 V outlet DO NOT USE AN EXTENSION CORD 2 Make sure the 115 V electrical supply circuit is equipped with fuses or circuit breakers of proper capacity 3 DC emergency pumps are designed for handling cle...

Page 2: ...state Discharge Feet of Head 5 1 5 m 10 3 m 15 4 6 m 28 85 m Flow GPM LPM 12 7 volts 43 163 35 132 27 102 Shut off Head This system is a combination of a primary sump pump and a backup pump to your pr...

Page 3: ...Install the Fit Controller see Figure 3 by using the anchors provided For best cooling install wall mount configuration The controller should be located at least 3 1 m above the sump 9 Connect the lea...

Page 4: ...controllerwillturnthepumponand off a few times before running the pump continuously This is to purge a suspected air lock If the high water float is removed unplugged the resulting controller and pump...

Page 5: ...DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT FIT CONTROLLER OUTLET CONTROLLER HI WATER REED SENSOR 1 1 2 SCH 40 PVC PIPE X 10 254 mm LG 1 1 2 SCH 40 PVC TEE NOTE CHECK VALVE SC...

Page 6: ...oller 1 155368 9 Fuse 30 amp automotive blade type 1 016918 10 High water float N C 1 155653 11 Battery box asm box and cover 1 10 0764 12 Hardware pak charger switch mode 2 152864 13 Pump M53 115V 1...

Page 7: ...ed Z Control Connected Searching Broadcasting SSID or Dormant Note will not persist if pump didn t pump water See also the laminated label affixed to the controller s cord This cord label also describ...

Page 8: ...oints Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 3 If fuse is blown replace with 30 amp automotive blade fuse e Remove pump Check f...

Page 9: ...rol Cloud will also be updated with the firmware update information and notification to email accounts will occur 5 You now should go back to the Z Control app to find your new device set up in the lo...

Page 10: ...ection to router is not successful If you need to force the Fit into AP mode again press the Z Control button for 12 seconds See Figure A This will cause the Fit to re enter AP mode and begin transmit...

Page 11: ...ng installed After up to 1 minute the Fit will restart and return to normal operation The Fit s alert history on the Z Control Cloud will also be updated with the firmware upgrade information and nofi...

Page 12: ...s by products capable of causing the CO detector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year...

Reviews: