PREINSTALLATION CHECKLIST

 

1.  Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer 

before using.

2.  Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be 

retained for future reference.

SEE BELOW FOR 

LIST OF WARNINGS

1.  Testing  for  ground.  As  a  safety  measure  each  electrical  outlet 

should be checked for ground using an Underwriters Laboratory 

listed circuit analyzer, which will indicate if the power, neutral and 

ground wires are correctly connected to your outlet. If they are not, 

call a qualified, licensed electrician.

2.  For your protection, always disconnect the power supply from its 

power source before handling the components of your DC backup 

pump or the primary pump.

3.  Installation and servicing of electrical circuits and hardware should 

be performed by a qualified, licensed electrician. 

4. 

All  electrical  and  safety  codes  must  be  followed  including  the 

National Electrical Code and all applicable local codes. 

5.   It is the owner’s responsibility to check the battery and 

battery connection at least once a month. Batteries 

contain acid, and caution must be taken when handling.

6.  Risk of electric shock. These pumps have not been investigated 

for 

use in swimming pools and marine areas.

7.  Prop65 Warning for California residents: 

 

: Cancer and  Reproductive Harm- 

        www.P65Warning.ca.gov.

1.  Make sure there is a properly grounded 115 V receptacle available. 

Do not use primary pump circuit. T

he location must be within 6' 

(1.8 m) of the control box and battery. The power supply for your 

DC control system plugs directly into the 115 V outlet. 

DO NOT USE 

AN EXTENSION CORD.

2.  Make sure the 115 V electrical supply circuit is equipped with 

fuses or circuit breakers of proper capacity.

3.  DC emergency pumps are designed for handling clear water. Do 

not use 

in septic tanks to pump effluent or in sewage pits to pump 

sewage.

4.  Repair and service of your DC backup system should be performed 

by an authorized service station.

5.  The installation of DC automatic backup pumps requires the use of 

a variable level float switch for operation. It is the responsibility of 

the installing party to ensure that the float switch will not hang up 

on the pump apparatus or pit peculiarities and is secured so the 

pump will turn “on” and “off”. It is recommended that the pit be 

18" (45.7 cm) in diameter or larger to accommodate both a primary 

and a DC backup pump.

6.  For indoor use only.

CAUTION

SEE BELOW FOR 

LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

CAUTION

    Turbulence  caused  by  high-velocity  incoming 

water can cause sump pumps to airlock. If this condition exists, 

the incoming water must be baffled to avoid excessive turbulence.

© Copyright 2022 Zoeller

®

 Co. All rights reserved.

NOTICE TO INSTALLER: Instructions must remain with installation.

FM3148

0622

Supersedes

0322

DATE INSTALLED:

MODEL NUMBER:

PREASSEMBLED SUMP PUMP SYSTEM WITH BATTERY BACKUP

MODEL 508 - 12 V DC BATTERY BACKUP SYSTEM

WITH 115 V AC POWERED SUMP PUMP

MODEL M53 OR M63 OR M98

INSTALLATION INSTRUCTIONS

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO

:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO

:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL

: (502) 778-2731 • 1 (800) 928-PUMP • 

FAX

: (502) 774-3624

Visit our website:

zoellerpumps.com

Patent No. D740329

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

 AQUANOT FIT 508/53, 508/63, 508/98

P/N155891-C

Summary of Contents for ProPak AQUANOT FIT 508/63

Page 1: ...5 V outlet DO NOT USE AN EXTENSION CORD 2 Make sure the 115 V electrical supply circuit is equipped with fuses or circuit breakers of proper capacity 3 DC emergency pumps are designed for handling cle...

Page 2: ...state Discharge Feet of Head 5 1 5 m 10 3 m 15 4 6 m 28 85 m Flow GPM LPM 12 7 volts 43 163 35 132 27 102 Shut off Head This system is a combination of a primary sump pump and a backup pump to your pr...

Page 3: ...Install the Fit Controller see Figure 3 by using the anchors provided For best cooling install wall mount configuration The controller should be located at least 3 1 m above the sump 9 Connect the lea...

Page 4: ...controllerwillturnthepumponand off a few times before running the pump continuously This is to purge a suspected air lock If the high water float is removed unplugged the resulting controller and pump...

Page 5: ...DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT FIT CONTROLLER OUTLET CONTROLLER HI WATER REED SENSOR 1 1 2 SCH 40 PVC PIPE X 10 254 mm LG 1 1 2 SCH 40 PVC TEE NOTE CHECK VALVE SC...

Page 6: ...oller 1 155368 9 Fuse 30 amp automotive blade type 1 016918 10 High water float N C 1 155653 11 Battery box asm box and cover 1 10 0764 12 Hardware pak charger switch mode 2 152864 13 Pump M53 115V 1...

Page 7: ...ed Z Control Connected Searching Broadcasting SSID or Dormant Note will not persist if pump didn t pump water See also the laminated label affixed to the controller s cord This cord label also describ...

Page 8: ...oints Clean if required c Check for low battery Service battery if required d Check 30 amp fuse on controller see fig 3 If fuse is blown replace with 30 amp automotive blade fuse e Remove pump Check f...

Page 9: ...rol Cloud will also be updated with the firmware update information and notification to email accounts will occur 5 You now should go back to the Z Control app to find your new device set up in the lo...

Page 10: ...ection to router is not successful If you need to force the Fit into AP mode again press the Z Control button for 12 seconds See Figure A This will cause the Fit to re enter AP mode and begin transmit...

Page 11: ...ng installed After up to 1 minute the Fit will restart and return to normal operation The Fit s alert history on the Z Control Cloud will also be updated with the firmware upgrade information and nofi...

Page 12: ...s by products capable of causing the CO detector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year...

Reviews: