background image

 FM2527

0315

Supersedes

0708

NOTICE TO INSTALLER:  Instructions must remain with installation.

Owner’s Information

Model Number:

 ______________________

  Date Code:

   _________________

Job Name:  ______________________________________________________ 

Dealer:

   _________________________________________________________

Date of Purchase:  _______________________________________________

Contractor:

 _____________________________________________________

Date of Installation:

  _______________________________________________

System Readings During Operation:  Voltage

 __________

 Amps  _________

OWNER’S MANUAL

Potable Water Jet Pumps

Safety Instructions

CAUTION

  This manual incorporates the installation, operation, maintenance, 

and service instructions into one document to aid in the ownership of 

a Zoeller potable water product. Please read and review this manual 

before installing the product. Many items contained within, when 

followed correctly, will not only ensure a long and problem-free life 

for the system, but also save time and money during installation. 

Should further assistance be necessary please call our Technical 

Service department at 1-800-928-PUMP.

Table of Contents

023015

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR 

PROPERTY  DAMAGE,  READ  AND  FOLLOW  ALL  SAFETY      

INSTRUCTIONS IN MANUAL AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION 

AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH 

THE PUMP.

This is a 

SAFETY ALERT SYMBOL.

When you see this symbol on the pump or in the 

manual, look for one of the following signal words 

and be alert to the potential for personal injury or 

property damage.

Warns of hazards that 

WILL

 cause serious personal    

injury, death or major property damage.
Warns of hazards that 

CAN 

cause serious personal 

injury, death or major property damage.
Warns of hazards that 

CAN 

cause personal injury 

or property damage.
Indicates special instructions which are very 

important and must be followed.

THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS 

PRIOR TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.

Safety Instructions ..........................................................................1
Limited Warranty.............................................................................2
Preinstallation Information ..............................................................3
Installation Procedures  ...............................................................4-6
Troubleshooting Checklist ..............................................................6
Parts List  ........................................................................................7
Notes ..............................................................................................8

  Congratulations on the purchase of the Zoeller Potable Water 

Jet Pump. For over sixty years the name Zoeller has represented 

the standard for submersible sump and sewage pumps. The 

same high quality workmanship and easy maintenance design 

has been incorporated into this line of potable water products. 

This Zoeller system will provide years of trouble-free service 

when installed according to the manufacturer recommendations.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624

Visit our web site:

zoellerpumps.com

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

© Copyright 2015 Zoeller

®

 Co. All rights reserved.

Summary of Contents for NE460

Page 1: ...en you see this symbol on the pump or in the manual look for one of the following signal words and be alert to the potential for personal injury or property damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major property damage Warns of hazards that CAN cause personal injury or property d...

Page 2: ...ife expectancy can occur if the ground water is not cold 86 ºF 30 ºC or contains air or gases 9 DO NOT run the pump dry DO NOT run the pump with a completely closed discharge DO NOT pump chemical or corrosive liquids Failure to follow above warnings could result in damage to the pump voiding the warranty and causing personal injury 10 CAUTION Check to be sure your power source is capable of handli...

Page 3: ...nstallation of jet pumps 2 Plastic pipe must have a minimum pressure rating of 160 PSI WELL TO PUMP PIPING 1 All offset piping should slope upwards from well to pump 2 Avoid dips or pockets in offset piping or air will accumulate at high points which will make priming difficult 3 Install unions at pump and at well to aid in servicing 4 Allow enough room around pump and piping installation for usin...

Page 4: ...r change the red and gray wire to voltage required Figure 5 Dual Voltage Wiring Diagram 2 To change voltage remove the rear access cover of the motor which is held in place with two 2 screws Change the red and gray wire on the transfer switch board to the voltage required Replace rear access cover before starting or operating pump Failure to do so can result in personal injury 3 Your pump motor ha...

Page 5: ... bracket MOTOR REPLACEMENT Figure 5 1 Uni Frame motors can be replaced in the field with any standard Nema J jet pump motor by following the following instructions CAUTION Before attempting to replace the motor make certain that the power supply is disconnected and the system pressure is relieved 2 Remove pump body Ref No 8 diffuser Ref No 7 impeller Ref No 6 and shaft seal Ref No 4 by following s...

Page 6: ... 2 Clean or replace defective control 3 Adjust switch settings Clean contacts with emery cloth if dirty 4 Repair leaks as necessary 5 Make sure above ground connections are tight Then repeat test If necessary pull piping and repair leak 6 Repair or replace Pump won t shut off 1 Wrong pressure switch setting or setting drift 2 Defective pressure switch 3 Loss of prime 4 Low well level 5 Fouled ejec...

Page 7: ...HORSEPOWER 1 2 3 4 MODEL NO PART NO 460 0006 461 0006 DESCRIPTION QTY 1 Motor Nema J Thd Motor Cover w Screws Screws Cover Motor Lead Wire 021301R 021302 136135A 98J105 1 2 1 98J107 1 2 1 2 3 Mounting Ring Hex Hd Cap Screws 3 8 x 3 4 135314 4 135314 4 4 5 6 7 8 9 10 Ring Square Cut Seal Rotary w Spring Impeller Diffuser Rubber Diffuser Pump Body Plug Priming 131100 132428 132583 1 139348 132424 1 ...

Page 8: ... O BOX 16347 Louisville KY 40256 0347 SHIPTO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Visit our web site zoellerpumps com Copyright 2015 Zoeller Co All rights reserved ...

Reviews: