CARE AND MAINTENANCE
WARNING
: Always disconnect pump from power source
before handling.
At least every three months inspect and test
operation:
1.. Check to be sure green ‘system ready’ light is on
(indicates AC power is on and there are no alarm
conditions)
2. Test for operation:
A. Unplug primary pump and controller.
Fill basin with water to the ‘on’ level of the backup
pump and allow the pump to run for several
minutes.
NOTE: The alarm will sound approximately one
second after the pump starts to run.
B. Push the Silence/reset button - the alarm will shut
off. The pump will shut off after the water level is
lowered and the float drops to the ‘off’ position.
Hold the Silence/reset button for three seconds
to reset the controller and clear any alarms or
indicators
C. Plug the controller and the primary pump into the
115V outlet. The primary pump will turn on and
then off when water reaches normal level.
The pump will continue to run after the float is
lowered or until the controller senses water is
being pumping. The four circle lights will be blue.
The battery light will flash slowly after the test as
it recharges the battery. The lights will turn green
once the battery is recharged.
10. The four circle LED’s will be blue when
charging the battery. The battery LED will flash
slowly. Once charging is complete, all four
circle LED’s will turn green.
AC
POWER
FLOAT
STATUS
BATTERY
DC
PUMP
SILENCE
TEST
24/7 BASEMENT
PROTECTION
USB
RESET
FLOAT
DC
PUMP
FUSE
30 AMP
by
FW2065 A
P L U S
1-800-584-8089
BasementSentry.com
DC POWER
+ 15V DC 1.6A
Solid green light
when charged
Press to
silence
alarms
10
START-UP AND OPERATION
AC
POWER
FLOAT
STATUS
BATTERY
DC
PUMP
SILENCE
TEST
24/7 BASEMENT
PROTECTION
USB
RESET
FLOAT
DC
PUMP
FUSE
30 AMP
by
1-800-584-8089
BasementSentry.com
DC POWER
+ 15V DC 1.6A
1
2A
2A
2C
2B
Summary of Contents for Basement Sentry STBB200
Page 24: ...24 2020 All rights reserved ...