FIGURE 4

SK2962

SK2961

EXPLODED VIEW - DC PUMP

PUMP ASSEMBLY

FIGURE 3

FIG. 4

DC PUMP

DISCHARGE TEE

REDUCER FITTING

CLAMP

CHECK VALVE ASSEMBLY

CLAMP

BATTERY BOX

12 VOLT

MARINE BATTERY

SUPPLIED BY USER

FIG. 3

CLAMP

WHITE LEAD TO POSITIVE

BLACK LEAD

TO DC PUMP

WHITE LEAD

 TO POSITIVE

BLACK LEAD

TO NEGATIVE

TO FLOAT

WHITE LEAD

30 AMP FUSE

DC CONTROL BOX

BLACK LEAD

TO NEGATIVE

TO FLOAT SWITCH

GREEN LEAD

SPLICER

FLOAT SWITCH

DC PUMP

Summary of Contents for AquaNot 508 Series

Page 1: ...ontrol system plugs directly into the 115V 230V outlet DO NOT USE AN EXTENSION CORD 2 Make sure the 115V 230V electrical supply circuit is equipped with fuses or circuit breakers of proper capacity 3 DC emergency pumps are designed for handling clear water Do not use in septic tanks to pump effluent or sewage pits to pump sewage 4 Repair and service of your DC backup system should be performed by ...

Page 2: ... and lower the water to the normal operating level and shut off b The yellow charging light should be on The charger is replacing the energy consumed during the test The green light will come on after the charger has replaced the energy consumed during the test 3 Adddistilledwatertobatterywhennecessaryperbatterymanufacturer s instructions CAUTION Battery acid is dangerous Take proper safety precau...

Page 3: ...er precaution must be taken when handling Battery box will accomodate a maximum battery size of 13 342 mm Length x 7 178 mm Width x 9 241 mm Height BATTERY SELECTION The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure The DC pump electronic controls and all the parts required for installation are included except the batter...

Page 4: ...rimary sump pump and the control box should be on separate circuits 17 Reconnect power to primary sump pump 18 Optional A dongle may be used to input a name and number into the charger for service information to the end user 19 Optional On the bottom of the charger there is a pair of dry contacts to signal an auxiliary device of a low battery high water and reverse polarity alarm condition This si...

Page 5: ...VEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP FIG 1 DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX DC CHARGER OUTLET CHARGER R R BATTERY BOX OUTLET PRIMARY PUMP DC PUMP INSTALLED IN LINE WITH COLUMN PUMP IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP 1 MIN OUTLET CHARGER DC CHARGER R R SK2959 SK2960 25 4 MM 25 4 MM ...

Page 6: ...RGE TEE REDUCER FITTING CLAMP CHECK VALVE ASSEMBLY CLAMP BATTERY BOX 12 VOLT MARINE BATTERY SUPPLIED BY USER FIG 3 CLAMP WHITE LEAD TO POSITIVE BLACK LEAD TO DC PUMP WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE TO FLOAT WHITE LEAD 30 AMP FUSE DC CONTROL BOX BLACK LEAD TO NEGATIVE TO FLOAT SWITCH GREEN LEAD SPLICER FLOAT SWITCH DC PUMP ...

Page 7: ...screen shows current alarms The cycle counter screen shows how many times the DC float has been activated The AC power loss counter screen shows how many times the AC power has been removed from the charger Optional a screen may also show the name and number of a service provider The 6 LED lights also display information about the charger at a glance The red AC power light will be on if AC power i...

Page 8: ...arantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of the Control It is for this reason that Zoeller offers its own line of batteries We offer both a Water Acid Deep Cycle Battery and maintenance free AGM battery which can run the pump continuously for over 7 hours These times are based on continuous pumping at 8 2 4 mm of static hea...

Reviews: