Zoeller 810 Owner'S Manual Download Page 2

2

© Copyright 2010 Zoeller Co. All rights reserved.

than in raw sewage pumping applications.  The warranty set out in the 
paragraph above is in lieu of all other warranties expressed or implied; 
and we do not authorize any representative or other person to assume 
for us any other liability in connection with our products.

Contact Manufacturer at, 3649 Cane Run Road, Lou is ville, Ken tucky  
40211, Attention: Cus tom er Ser vice De part ment to obtain any need ed 
repair or re place ment of part(s) or additional in for ma tion pertaining to 
our warranty.

MANUFACTURER EXPRESSLY DIS CLAIMS LI A BIL I TY FOR SPE CIAL, 
CON SE QUEN TIAL OR IN 

CI DEN TAL DAM 

AG ES OR BREACH 

OF EX 

PRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED 

WAR RAN TY OF FIT NESS FOR A PAR TIC U LAR PUR POSE AND OF 
MER CHANT ABIL I TY SHALL BE LIM IT ED TO THE DU RA TION OF THE 
EX PRESSED WAR RAN TY.

Some states do not allow limitations on the duration of an implied warranty, 
so the above limitation may not apply to you. Some states do not allow 
the exclusion or limitation of incidental or con se quen tial dam ag es, so the 
above lim i ta tion or exclusion may not apply to you.

This warranty gives you specifi c legal rights and you may also have other 
rights which vary from state to state.

Limited Warranty

Manufacturer warrants, to the purchaser and subsequent owner during 
the warranty period, every new product to be free from defects in material 
and workmanship under normal use and service, when properly used 
and maintained, for a period of one year from date of purchase by the 
end user, or 18 months from date of original manufacture of the product, 
whichever comes fi rst.  Parts that fail within the warranty period, one year 
from date of purchase by the end user, or 18 months from the date of 
original manufacture of the product, whichever comes fi rst, that inspections 
determine to be defective in material or workmanship, will be repaired, 
replaced or remanufactured at Manufacturer's option, provided however, 
that by so doing we will not be obligated to replace an entire assembly, 
the entire mechanism or the complete unit.  No allowance will be made 
for shipping charges, damages, labor or other charges that may occur 
due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any 
material or product that has been disassembled without prior approval 
of Manufacturer, subjected to misuse, misapplication, neglect, alteration, 
accident or act of God; that has not been installed, operated or maintained 
in accordance with Manufacturer's installation instructions; that has been 
exposed to outside substances including but not limited to the following:  
sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives 
(oil, gasoline, solvents, etc.), or other abrasive or corrosive substances, 
wash towels or feminine sanitary products, etc. in all applications other 

1.  Zoeller Progressing Cavity Grinder Pumps are designed for grind ing 

and pumping sanitary sewage from sub mers ible lift stations.  The 
pump is in tend ed to grind and pump reasonable quan ti ties of items 
normally found in sanitary sewage applications.

2.  Zoeller 810 and 815 Progressing Cavity Grinder Pumps can be 

installed in new applications or as a direct replacement for any grinder 
application of like size and capacity. Some rail system retrofi t kits are 
available.

3.  The 810 and 815 can be installed in a Prepackaged Job Ready System 

or may be used in a Field Assembled basin package. Page 5 shows 
a couple of the Pre pack aged Systems. Field Assembled Systems are 
dis cussed on page 3.

4.  Zoeller 810 and 815 Grinder Pumps can be retrofi tted to ex ist ing 

positive displacement pump installations.

Applications

Preinstallation Checklist

1.

 Inspect your progressing cavity grinder pump.

 If the unit has been 

damaged in shipment, contact your dealer before installing. 

Do Not

 

remove the test plug in the cover nor the motor housing.

2.

  Carefully read all literature

 to familiarize yourself with details re gard ing 

in stal la tion and use. Retain materials for future reference.

1.

  Make sure pump connection con tains a ground ter mi nal.

 The power 

cord on all Zoeller Progressing Cavity Grind er Pumps con tains a green 
con duc tor for grounding to help protect you against the pos si bil i ty of 
electric shock.

2. 

Make certain the electrical service is within reach of the power 
supply cord

.

3.

 Make sure any panels and branch circuits are equipped

 with 

proper size fuses and circuit break ers. An in de pen dent pow er circuit is 
rec om mend ed, sized ac cord ing to the National Elec tri cal Code, for the 
current shown on the grinder pump name plate.

4.

 For your protection, always dis con nect the pow er source to the 

grinder pump before han dling.

 All grinder pumps must be prop er ly 

ground ed and wired in ac cor dance with the “Na tion al Elec tri cal Codes” 
and all local codes and ordinances.

5. Installation of electrical hardware and checking of control pan 

els 

and circuits should be performed by a qualifi ed  li censed electrician.

6. Risk of electrical shock - These pumps have not been in ves ti gat ed for 

use in swimming pool areas.

7. According to the state of California (Prop 65), this product contains 

chemicals known to the state of California to cause can cer and birth 
defects or other reproductive harm.

1.

 Make sure the power source is capable of handling the 

electrical re quire ments of the grinder pump, as indicated on the 
nameplate.

2.

 A dis con nect switch should be installed ahead of the pump.

3. The progressing cavity grinder pumps are operated by variable level 

fl oat control switches. It is the re spon si bil i ty of the in stall ing party to 
see that fl oat control switches will not hang up on the grinder pump 
or other pit peculiarities and are secured so that the grinder pump will 
shut off. It is rec om mend ed to use rigid pipe and fi ttings and the pit be 
at least 24" in diameter for simplex sys tems and 36" in di am e ter for 
duplex systems or larger.

4.  Grinder installations should be checked yearly for debris and/or build up 

which may interfere with the “ON” or “OFF” positions of variable lev el 
fl oat control switches. Repair and service, other than cutter as sem bly 
main te nance, should be per formed by Zoeller En gi neered Products 
au tho rized service stations only.

5. Maximum operating tem 

per a ture must not ex 

ceed 130°F,

(54°C).

6. 

Do not operate an unsubmerged progressing cavity pump. 

Dry pump 

operation may damage the hydraulic stator due to lack of lubrication. 

Do not run dry.

 

7. 

To ensure proper pump operation, a swing or fl apper style check 
valve must be installed in the pump discharge line. A faulty or 
non-functional check valve when combined with a pressure sewer 
may prevent the pump from starting.

Do not attempt to turn star cutter lo cat ed on 

bottom of the unit with fi ngers.

 Use a wrench when check ing 

or re mov ing star cutter.

SEE BELOW FOR
LIST OF CAUTIONS

SEE BELOW FOR
LIST OF WARNINGS

 Progressing cavity grinder pumps are designed 

for pressure sewer applications. A UL listed and CSA certifi ed  pres-
sure relief valve must be installed in the system to prevent excessive 
pressure buildup.

Summary of Contents for 810

Page 1: ...personal injury or property damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major proper...

Page 2: ...bled basin package Page 5 shows a couple of the Prepackaged Systems Field Assembled Systems are discussed on page 3 4 Zoeller 810 and 815 Grinder Pumps can be retrofitted to existing positive displace...

Page 3: ...onal 3 Pump motors are single phase Single phase motors require a run capacitor which is mounted in the the upper cap of the pump ref page 4 The units have an internal thermal overload 4 The 810 815 p...

Page 4: ...switch operation Note Cable must be mounted in horizontal position Determining Pumping Range in Inches 1 inch 2 5 cm Use only as a guide Due to weight of cable pumping range above horizontal is not e...

Page 5: ...limited to the National Electrical Code local regional and or state plumbing codes etc Typical Outdoor Grinder Pumping System Installations FIGURE 4A PACKAGED SYSTEM WITH FLEXIBLE HOSE DISCONNECT SK2...

Page 6: ...nstructions found in this manual and located inside the panel enclosure 15 Remove any debris from the basin Using clean water check the system for proper operation 16 Seal and secure the lid using the...

Page 7: ...material removed from the disc As a starting point remove shims of the same thickness as the amount machined from the cutter disc step 6 above Final running clearance must be between 0 007 and 0 012 B...

Page 8: ...float switch held down or defective incorrect wiring in control panel water in cap assembly check valve not installed or malfunctioning Incorrect voltage impeller or cutter blocked negative head disc...