WARNING
• ELECTRICAL SHOCK ALERT.
Before installing this product, have the electrical circuit checked by an electrician to ensure proper
grounding. All electrical installations must conform to the National Electric Code and all local
codes.
• ELECTRICAL SHOCK ALERT.
Connect this product to a properly-grounded 115 volt circuit equipped with a Ground Fault Circuit
Interrupter (GFCI) device. Make sure the electrical supply circuit is equipped with fuses or circuit
breakers with a minimum capacity of 15 amps.
• ELECTRICAL SHOCK ALERT.
Never use an extension cord.
• ELECTRICAL SHOCK ALERT.
These pumps are supplied with a 3-prong grounded plug to help protect you against the possibility
of electrical shock. DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN.
• ELECTRICAL SHOCK ALERT.
Do not remove or replace the power cord.
• ELECTRICAL SHOCK ALERT.
Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord.
• CHEMICAL ALERT.
This product contains chemicals known to the state of California to cause cancer and birth defects
or other reproductive harm.
• PERSONAL INJURY ALERT.
This pump contains oil, which becomes hot when operating. Allow 2-1/2 hours after disconnecting
before attempting any service.
CAUTION
• PERSONAL INJURY OR PRODUCT DAMAGE MAY RESULT.
This pump operates on 115 volts. Make certain that the power source conforms to the
requirements of your equipment.
• PRODUCT DAMAGE MAY RESULT.
The continuous operating water temperature for this pump must not exceed 104°F (40°C).
• PRODUCT DAMAGE MAY RESULT.
This pump is designed to pump water only. It has not been evaluated for pumping chemicals or
corrosive materials.
• PRODUCT DAMAGE MAY RESULT.
Inspect the pump regularly for damage and perform routine maintenance as needed. Remove any
debris that may build up around the on/off operation of the float.
• PROPERTY DAMAGE MAY RESULT.
This product requires a 3/16-in vent hole to be drilled in the discharge pipe, level with the top of
the pump. The vent hole should be checked periodically for clogs. It is normal for water to come
out of this vent hole during pump operation.
• PROPERTY OR PRODUCT DAMAGE MAY RESULT.
This pump is not designed for pumping effluent or sewage.
• PRODUCT DAMAGE MAY RESULT.
This pump is not designed for continuous operation.