WARNING

•  ELECTRICAL SHOCK ALERT. 

Before installing this product, have the electrical circuit checked by an electrician to ensure proper 

grounding. All electrical installations must conform to the National Electric Code and all local 

codes.

•  ELECTRICAL SHOCK ALERT. 

Connect this product to a properly-grounded 115 volt circuit equipped with a Ground Fault Circuit 

Interrupter (GFCI) device. Make sure the electrical supply circuit is equipped with fuses or circuit 

breakers with a minimum capacity of 15 amps.

•  ELECTRICAL SHOCK ALERT. 

Never use an extension cord.

•  ELECTRICAL SHOCK ALERT. 

These pumps are supplied with a 3-prong grounded plug to help protect you against the possibility 

of electrical shock. DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN.

•  ELECTRICAL SHOCK ALERT. 

Do not remove or replace the power cord.

•  ELECTRICAL SHOCK ALERT. 

Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. 

•  CHEMICAL ALERT. 

This product contains chemicals known to the state of California to cause cancer and birth defects 

or other reproductive harm.

•  PERSONAL INJURY ALERT.

 

This pump contains oil, which becomes hot when operating. Allow 2-1/2 hours after disconnecting 

before attempting any service.

CAUTION

•  PERSONAL INJURY OR PRODUCT DAMAGE MAY RESULT. 

This pump operates on 115 volts. Make certain that the power source conforms to the 

requirements of your equipment.

•  PRODUCT DAMAGE MAY RESULT. 

The continuous operating water temperature for this pump must not exceed 104°F (40°C).

•  PRODUCT DAMAGE MAY RESULT. 

This pump is designed to pump water only. It has not been evaluated for pumping chemicals or 

corrosive materials.

•  PRODUCT DAMAGE MAY RESULT. 

Inspect the pump regularly for damage and perform routine maintenance as needed. Remove any 

debris that may build up around the on/off operation of the float.

•  PROPERTY DAMAGE MAY RESULT.

 

This product requires a 3/16-in vent hole to be drilled in the discharge pipe, level with the top of 

the pump. The vent hole should be checked periodically for clogs. It is normal for water to come 

out of this vent hole during pump operation.

•  PROPERTY OR PRODUCT DAMAGE MAY RESULT.

 

This pump is not designed for pumping effluent or sewage.

•  PRODUCT DAMAGE MAY RESULT. 

This pump is not designed for continuous operation.

Summary of Contents for 1073-0001

Page 1: ...ber Purchase Date Zoeller is a registered trademark of Zoeller Co All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE SW1139 B Español p 9 ...

Page 2: ... flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in a flammable and or explosive atmosphere Failure to follow these warnings could result in death or serious injury and or property damage RISK OF ELECTRIC SHOCK These pumps have not been investigated for use in swimming pool and marine areas RISK OF ELECTRIC SHOCK Always disconnect power source before attempting to i...

Page 3: ...ause cancer and birth defects or other reproductive harm PERSONAL INJURY ALERT This pump contains oil which becomes hot when operating Allow 2 1 2 hours after disconnecting before attempting any service CAUTION PERSONAL INJURY OR PRODUCT DAMAGE MAY RESULT This pump operates on 115 volts Make certain that the power source conforms to the requirements of your equipment PRODUCT DAMAGE MAY RESULT The ...

Page 4: ... draining back into the sump basin when it is not operating The sump basin must be at least 18 in deep and 10 in diameter NOTES Before installing pump Have the electrical circuit checked by an electrician to ensure it is on a dedicated circuit with proper grounding Connect pump to a grounded circuit equipped with a ground fault circuit interruptor GFCI device BE CERTAIN the pump power source is di...

Page 5: ...ded to pump discharge The discharge pipe should be the same size as the discharge of pump 1 1 2 in or larger NOTE Make sure there is enough room in the basin for the float to move freely If the float is restricted the pump will not operate 3 Drill a 3 16 in vent hole in the discharge pipe level with the top of pump It is normal for water to spray from this hole when the pump is operating 3 16 in V...

Page 6: ...ING Do not use an extension cord NOTE Tape the electrical cord to the discharge pipe to prevent it from interfering with the motion of the float 5 Test the operation of the pump by pouring water into the sump basin 6 Install a sump basin cover to complete the installation A A Sump basin cover 6 115 V GFCI Outlet 5 115 V GFCI outlet 4 INSTALLATION INSTRUCTIONS ...

Page 7: ...ch are not installed in accordance with normal applicable local codes ordinances and good trade practices and e if the unit is used for purposes other than for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced under this warranty must be returned to the manufacturer at Kendallville Indiana or such other place as the manufacturer may designate ...

Page 8: ...p is air locked 4 Clean out vent hole in discharge pipe 5 Vertical pumping distance is too high 5 Reduce the vertical distance to correspond with the performance chart in the instructions Pump runs continuously 1 Float is stuck in the on position 1 Make sure the float can move freely 2 Float switch is defective 2 Replace float switch Pump runs but delivers little water 1 Pump is air locked 1 Clean...

Reviews: