4.   Make sure your hands are dry and you are 

not standing in water. Connect the pump to a 

properly-grounded, GFCI electrical outlet.  

 

WARNING:

 Do not use an extension cord. 

 

NOTE: 

Tape the electrical cord to the discharge 

pipe to prevent it from interfering with the 

motion of the float.

5.  Test the operation of the pump by pouring water 

into the sump basin.

6.   Install a sump basin cover to complete the 

installation.

A

A

Sump basin

cover

6

115 V

GFCI Outlet

5

115 V

GFCI outlet

4

INSTALLATION INSTRUCTIONS

Summary of Contents for 1073-0001

Page 1: ...ber Purchase Date Zoeller is a registered trademark of Zoeller Co All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE SW1139 B Español p 9 ...

Page 2: ... flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in a flammable and or explosive atmosphere Failure to follow these warnings could result in death or serious injury and or property damage RISK OF ELECTRIC SHOCK These pumps have not been investigated for use in swimming pool and marine areas RISK OF ELECTRIC SHOCK Always disconnect power source before attempting to i...

Page 3: ...ause cancer and birth defects or other reproductive harm PERSONAL INJURY ALERT This pump contains oil which becomes hot when operating Allow 2 1 2 hours after disconnecting before attempting any service CAUTION PERSONAL INJURY OR PRODUCT DAMAGE MAY RESULT This pump operates on 115 volts Make certain that the power source conforms to the requirements of your equipment PRODUCT DAMAGE MAY RESULT The ...

Page 4: ... draining back into the sump basin when it is not operating The sump basin must be at least 18 in deep and 10 in diameter NOTES Before installing pump Have the electrical circuit checked by an electrician to ensure it is on a dedicated circuit with proper grounding Connect pump to a grounded circuit equipped with a ground fault circuit interruptor GFCI device BE CERTAIN the pump power source is di...

Page 5: ...ded to pump discharge The discharge pipe should be the same size as the discharge of pump 1 1 2 in or larger NOTE Make sure there is enough room in the basin for the float to move freely If the float is restricted the pump will not operate 3 Drill a 3 16 in vent hole in the discharge pipe level with the top of pump It is normal for water to spray from this hole when the pump is operating 3 16 in V...

Page 6: ...ING Do not use an extension cord NOTE Tape the electrical cord to the discharge pipe to prevent it from interfering with the motion of the float 5 Test the operation of the pump by pouring water into the sump basin 6 Install a sump basin cover to complete the installation A A Sump basin cover 6 115 V GFCI Outlet 5 115 V GFCI outlet 4 INSTALLATION INSTRUCTIONS ...

Page 7: ...ch are not installed in accordance with normal applicable local codes ordinances and good trade practices and e if the unit is used for purposes other than for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced under this warranty must be returned to the manufacturer at Kendallville Indiana or such other place as the manufacturer may designate ...

Page 8: ...p is air locked 4 Clean out vent hole in discharge pipe 5 Vertical pumping distance is too high 5 Reduce the vertical distance to correspond with the performance chart in the instructions Pump runs continuously 1 Float is stuck in the on position 1 Make sure the float can move freely 2 Float switch is defective 2 Replace float switch Pump runs but delivers little water 1 Pump is air locked 1 Clean...