1.  Read all instructions before beginning installation.

                      

  2.  Be certain that basin is on a firm level surface.

                      

  3.  Do not use an automatic plumbing vent device.

  4.  Do not over-torque lid attachment screws.

                      

  5.  Always use a check valve on the discharge line.

  6.  Test operation of pump per STEP 6 on page 7.

Ten Helpful Hints For Easy Installation

Performance Characteristics

  7.  Always  provide  some  means  to  disconnect  basin  from 

plumbing for maintenance purposes.

  8.  Run unit at least once a month to verify proper operation.

  9.  The model number and date code can be found on the lid 

warning label.

 10.  Plug pump into a properly grounded GFCI receptacle.

009897

  1.  DO  read  all  installation  material  included  with  the  pump.     

                     

  2.  DO inspect unit for any visible damage caused by shipping. 

Contact dealer if unit appears to be damaged.              

                      

  3.  DO clean all debris from the basin and pump.   

                      

  4.  DO  always  disconnect  pump  from  power  source  before 

handling. DO always connect to a separately protected and 
properly grounded ground fault protected circuit. DO NOT 
ever cut, splice or damage power cord.  DO NOT carry or lift 
pump by its power cord. DO NOT use an extension cord.  

Do’s  And  Don't’s  For  Installing  A  Unit

  5.  DO NOT use

 

a discharge pipe smaller than the pump dis-

charge size. 

                      

  6.  DO test pump immediately after installation to be sure that 

the system is working properly. 

                      

  7.  DO review all applicable local and national codes and verify 

that the installation conforms to each of them. 

  8.  DO NOT install unit in the ground. 

TOTAL DYNAMIC HEAD/FLOW

PER MINUTE

EFFLUENT AND DEWATERING

19.25 ft.(5.9m)

Shut-off Head:

MODEL

15

10

Feet

5

4.6

3.0

34
19

1.5

Meters

43

Gal.

72

129

163

Liters

53

PUMP PERFORMANCE CURVE

MODEL 53

FLOW PER MINUTE

LITERS  0

80

5

20

15

10

GALLONS

TOT

AL

 DYNAMIC HEAD

0

2

4

6

10

20

30

160

40

50

FEET

METERS 

Summary of Contents for 105

Page 1: ...o reduce the risk of electrical shock a properly grounded receptacle of grounding type must be installed and protected by a ground fault circuit interrupter GFCI in accordance with national electrical code and local codes 6 Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician 7 Risk of electric shock These pumps have not been in...

Page 2: ...ow limitations on the duration of an implied warranty so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Limited Warranty ELECTRICAL PRECAUTIONS...

Page 3: ...ontact dealer if unit appears to be damaged 3 DO clean all debris from the basin and pump 4 DO always disconnect pump from power source before handling DO always connect to a separately protected and properly grounded ground fault protected circuit DO NOT ever cut splice or damage power cord DO NOT carry or lift pump by its power cord DO NOT use an extension cord Do s And Don t s For Installing A ...

Page 4: ... side standard IMPORTANT Check local and state codes before using the internal trap option 1 1 Figure 1 1A and 1 1B are typical configurations for installation of the drain systems The actual configuration will vary depending on your cabinet and sink configuration NOTE If installing the internal trap record the x dimension it will be required in Step 4 INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS F...

Page 5: ...ARD THE FLOAT Water stream will be visible from this hole during pump run periods IMPORTANT DISCHARGE PIPE PUMP DISCHARGE WEEP HOLE SK2002 STEP 3 Installation of the Gasket 3 1 Install the gasket into the gasket seat at the top of the basin Figure 3 1 SK3160 OVERLAP DETAIL GASKET SEAT FOAM GASKET GASKET SEAT DETAIL FOAM GASKET APPROXIMATELY 1 4 OVERLAP BASIN ...

Page 6: ...stallation Only 4 1 Cut the tailpipe to the dimension determined in Figure 4 1 4 2 Install the sink drain components to the lid as shown in Figure 4 2 4 3 Orient the lid assembly as shown in Figure 4 3 and secure the trap components HAND TIGHTEN the assembly to the lid at this time Adjustment will be required in Step 5 Note To ensure a proper water seal the extension must be installed as shown in ...

Page 7: ...LATION STEP 5 Final Assembly NOTE External plumbing configuration will vary depending on the location of basin location of main stack and available space 5 1 Place the pump in the basin as shown in Figure 5 1 NOTE If installing the internal trap rotate the tail pipe to the orientation shown in Figure 5 1 5 2 Install the lid components as shown in Figure 5 2 NOTE Pull excess cordage through the ope...

Page 8: ...13 2 Basin Tank 1 013017 013017 3 Discharge 1 013732 N A 4 Basin Lid 1 013018 013018 A 5 Hardware pack seal 1 154256 154256 6 Unicheck 1 30 0181 30 0181 Notes 1 Hardware pack consist of 8 1 4 20 x 1 1 8 long round head stainless steel machine screws 8 1 4 20 stainless steel hex nuts and 16 1 4 flat stainless steel washers along with 1 pipe cap and 1 o ring and 1 pipe seal Copyright 2017 Zoeller Co...

Reviews: