background image

3

WARNING

CAUTION

•  ELECTRICAL SHOCK ALERT. 

 

Before installing this product, have the electrical circuit checked by an electrician to ensure proper 

grounding. All electrical installations must conform to the National Electric Code and all local 

codes.

•  ELECTRICAL SHOCK ALERT.

 

Connect this product to a properly-grounded 115 volt circuit equipped with a Ground Fault Circuit 

Interrupter (GFCI) device.

•  ELECTRICAL SHOCK ALERT.

 

Do not handle pump or pump motor with wet hands or when standing on a wet or damp surface or 

in water.

•  ELECTRICAL SHOCK ALERT.

 

These pumps are supplied with a 3-prong grounded plug to help protect you against the possibility 

of electrical shock. DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN.

•  ELECTRICAL SHOCK ALERT.

 

BE CERTAIN the pump power source is disconnected before installing or servicing pump.

•  ELECTRICAL SHOCK ALERT.

 

Protect electrical cord from sharp objects, hot surfaces, oil and chemicals. Avoid kinking the cord. 

Replace or repair damaged or worn cords immediately.

•  CHEMICAL ALERT.

 

This product contains chemicals known to the state of California to cause cancer and birth defects 

or other reproductive harm.

•  PERSONAL INJURY ALERT

Provide a means of pressure relief if the pump discharge can be shut off or obstructed. Pumps 

operating with a closed discharge can create hot liquid, which can cause burns.

•  PERSONAL INJURY ALERT.

 

This pump is equipped with an automatic thermal overload and can restart without warning.

•  PERSONAL INJURY OR PRODUCT DAMAGE MAY RESULT.

 

Check to be sure your power source is capable of handling the voltage requirements of the motor, 

as indicated on the pump name plate.

•  PRODUCT DAMAGE MAY RESULT.

 

These pumps are not designed or intended to be used to handle sewage or effluent.

•  PRODUCT DAMAGE MAY RESULT.

 

This pump has been evaluated for use with WATER only.

•  PRODUCT DAMAGE MAY RESULT.

 

Maximum continuous operating water temperature for standard model pumps must not exceed 

104°F (40°C).

•  PRODUCT DAMAGE MAY RESULT.

 

Not designed for 24/7 operation. Design life is 4500 accumulated hours.

Summary of Contents for 1043-006

Page 1: ...ber Purchase Date Zoeller is a registered trademark of Zoeller Co All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE SW1177 A ...

Page 2: ... fuel oil kerosene etc Do not use in a flammable and or explosive atmosphere Failure to follow these warnings could result in death or serious injury and or property damage RISK OF ELECTRIC SHOCK These pumps have not been investigated for use in swimming pool areas RISK OF ELECTRIC SHOCK Always disconnect power source before attempting to install service or maintain the pump Never handle a pump wi...

Page 3: ...icals Avoid kinking the cord Replace or repair damaged or worn cords immediately CHEMICAL ALERT This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm PERSONAL INJURY ALERT Provide a means of pressure relief if the pump discharge can be shut off or obstructed Pumps operating with a closed discharge can create hot liquid which c...

Page 4: ...ired for Assembly PREPARATION INSTALLATION INSTRUCTIONS 1 Attach garden hose adapter to the pump discharge and then connect garden hose to adapter B DO NOT OVER TIGHTEN THE GARDEN HOSE OR HOSE ADAPTER Finger tight plus 1 4 to 1 2 turn should be sufficient 1 2 Place pump in the water on a hard surface Pump will operate continuously whether partly or fully submerged Avoid placing pump directly on sa...

Page 5: ...ense water IL2059 Low Water 1 5 2 To prevent unnecessary wear unplug the pump from the power output when not in use CAUTION Extended usage of the pump in a partially submerged or non submerged situation may cause the pump to overheat due to lack of heat dissipation from the water If this occurs the pump will shut itself off until the motor cools to its normal temperature Repeated overheating may c...

Page 6: ...that you are not standing in water Unplug pump Remove debris 1 2 If pump clogs unplug the pump from the power supply Attach one end of a garden hose to a spigot and the other end to pump discharge Turn on the spigot to run water through pump to clean it out 2 3 If the pump becomes clogged remove the screen and clean out the area Debris in the intake should be routinely removed from the bottom of t...

Page 7: ...outlet 2 Restricted discharge hose 2 Increase hose diameter to 3 4 in 3 Pump damaged 3 Replace pump 4 Plugged or kinked discharge 4 Clean and straighten hose Flow rate is low 1 Hose kinked 1 Straighten hose 2 Clogged impeller 2 Clear obstruction 3 Excessive length of hose 3 Reduce length of outlet hose Pump will not run 1 No power 1 Verify that unit is plugged into 115 volt outlet 2 Motor overheat...

Page 8: ...han for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced under this warranty must be returned to the manufacturer at Kendallville Indiana or such other place as the manufacturer may designate freight prepaid THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE ANY IMPLIED WARRAN...

Reviews: