H0430700.A - EN - 2014-05
5
Alarm:
•
Function: connect a relay to the alarm contact,
•
using a dry contact
•
between terminals 1-2 (220-240V 2A maximum when the alarm is on),
Remote «on/off» command:
•
Function: connect a remote «on/off» button.
•
using a potential-free, no polarity 220-240V ~ 50Hz contact,
•
connect the cable to the terminal block between terminals 9-10.
Heating priority:
•
Function: coupling to trigger the filtering pump (temperature test at least 5 minutes every hour, with filtering kept
running if the pool temperature is less than the requested temperature).
•
using a dry contact (no polarity I max. = 8 A)
•
between terminals 11-12.
A1-A2: supply of the power contactor coil for the filter pump
B: filtering clock
C: power contactor (three or two phased) powering the filter pump
motor
D: separate connection cable for the «heating priority» function
E: terminal block
F: fuse
G: separate connection cable for alarm contact relay
H: alarm contact relay
I: remote «on/off» switch
J: separate connection cable for the remote «on/off» command
2. Use
2.1 Presentation of the regulation
«On/off» button (press for 3 seconds)
Menu selection and access button
Return/Exit button
Value setting button
«Power» indicator On=appliance powered on
«Alarm» indicator Flashing = alarm message on the screen or operating fault
Display
Screen type
Starter screen (4 seconds)
Home screen
Content
Electronic Card firmware versions A1
(regulation) and A2 (display)
Date
Operating mode
Set point temperature
Water intake temperature
Heat pump status