WARNINGS

• Failure to respect the warnings may cause serious damage to the pool equipment or cause serious injury, even 

death.

• 

The appliance is intended for a specifi c pool use and must not be used for any use other than that for which it was 

designed.

• 

It is important that the equipment is operated by competent and qualifi ed (both physically and mentally) people 

who have previously received the instructi ons for use. All persons not meeti ng these criteria must not approach the 

appliance in order to avoid exposure to dangerous elements.

• Keep the appliance out of the reach of children.

• 

The device must be installed by a qualifi ed technician according to the manufacturer’s instructi ons and in compliance 

with local regulati ons. The installer is responsible for installati on of the equipment and for compliance with nati onal 

installati on  regulati ons.  Under  no  circumstances  can  the  manufacturer  be  held  liable  in  the  event  of  failure  to 

comply with applicable local standards.

• 

Incorrect installati on and/or use may cause serious damage to property or serious injuries (possibly causing death). 

• 

All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The consignee shall make 

reservati ons in writi ng on the carrier’s bill of lading if damage is detected, caused during transport (confi rmati on to 

be sent to the carrier within 48 hours by registered mail with acknowledgement of receipt). In the event of a device 

containing coolant that has been turned on its side, menti on your reservati ons in writi ng to the carrier.

• 

If the appliance suff ers a malfuncti on, do not try to repair the appliance yourself, contact a qualifi ed technician.

• 

Refer to the warranty conditi ons for details of the permitt ed water balance values for operati ng the appliance.

• 

Eliminati ng or shunti ng one of the safety devices automati cally voids the warranty, as does the replacement of parts 

using parts not manufactured by ourselves.

• 

Do not spray insecti cide or any other chemical (infl ammable or non-infl ammable) in the directi on of the appliance, 

as this may damage the body and cause a fi re.

• 

Heat pump, fi ltrati on pump and fi lter appliances are compati ble with all types of water treatment.

• 

For heat pump appliances or dehumidifi ers, do not touch the fan or insert a rod or your fi ngers through the grati ng 

when the appliance is in operati on. The fan rotates at high speed and may cause injuries or even death.

• 

The electrical supply to the appliance must be protected by a dedicated 30 mA diff erenti al residual current protecti on 

device, complying with the standards and regulati ons in force in the country where it is installed.

• 

Means for disconnecti on from the supply mains having a contact separati on in all poles that provide full disconnecti on 

under overvoltage category III, must be incorporated in the fi xed wiring in accordance with the wiring rules.

• 

Before carrying out any operati ons, check that:

 -

The voltage indicated on the maker’s plate of the appliance corresponds to the mains voltage, 

 - The power grid is adapted to the power requirements of the appliance, and is grounded. 

 -

The plug (where applicable) is suitable for the socket.

• 

In the event of abnormal functi on or the release of odours from the appliance, turn it of immediately, unplug it from 

its power supply and contact a professional.

• 

Before any interventi on on the appliance, ensure that the latt er is switched off  and disconnected from the power 

supply,  in  additi on  to  any  other  equipment  connected  to  the  appliance,  and  that  the  heati ng  priority  (where 

applicable) is deacti vated.

• 

Do not disconnect and reconnect the appliance to the power supply when in operati on.

• Do not pull on the power cord to disconnect it from the power supply.

• Do not handle the electrical elements with wet hands.

• 

Clean the terminal board or the power supply socket before connecti on.

• 

For any component or sub-assembly containing a batt ery: do not recharge or dismantle the batt ery, or throw it into 

a fi re. Do not expose it to high temperatures or direct sunlight.

• 

In stormy weather, unplug the appliance to prevent it from suff ering lightning damage.

• 

Do not immerse the appliance in water (with the excepti on of cleaners) or mud.

• 

Do not discharge R410A or R407C fl uid into the atmosphere. These are fl uorinated greenhouse eff ect gases, covered 

by the Kyoto Protocol, with a Global Warming Potenti al (GWP) = 1975 for R410A or 1653 for R407C - (Directi ve EC 

842/2006).

• 

According to French decree No. 2007-737, if the appliance has more than 2 kg of refrigerant gas (refer to manufacturer 

specifi cati ons), the cooling circuit must be checked for leakage at least once a year. This operati on must be carried 

out by a certi fi ed cooling appliance specialist.

Additi onal recommendati ons in relati on to the Pressure Equipment Directi ve (PED-97/23/EC)

Installati on and maintenance

The unit may not be installed close to combusti ble materials, or the air duct inlet of an adjacent building .

With some devices, it is essenti al to fi t protecti on grids if the unit is installed in an area with uncontrolled access.

During installati on, troubleshooti ng and maintenance, pipes may not be used as steps: the pipe could break under the weight, 

spilling refrigerant and possibly causing serious burns.

When servicing the appliance, the compositi on and state of heat carrying fl uid must be checked, as well as the absence of any 

refrigerant.

During the annual unit sealing test in accordance with applicable legislati on, the high and low pressure switches must be 

checked to ensure that they are securely fastened to the coolant circuit and that they cut-off  the electrical circuit when tripped.

During maintenance work, ensure there are no traces of corrosion or oil around cooling components.

Before beginning work on the cooling circuit, stop the device and wait for a few minutes before fi tti  ng the temperature and 

pressure sensors. Some elements such as the compressor and piping may reach temperatures in excess of 100°C and high 

pressures with the consequent risk of severe scalding. 

T

roubleshooti ng

All soldering work must be carried out by a someone qualifi ed to do so.

Replacement pipes must always be made of copper in compliance with standard NF EN 12735-1.

Leak detecti on, pressure test:

 -

never use oxygen or dry air, risk of fi re or explosion, 

 -

use dry nitrogen or the mixture of nitrogen and refrigerant indicated on the informati on plate, 

 -

the test pressure for both the high and low pressure circuits must not exceed 42 bar (for R410A), 20 bar and 15 bar (for 

R407C) in the case the device is equipped with the opti onal pressure gauge.

The  high pressure circuit  pipes  are made of  copper  and  have a diameter equal  to  or greater than  1’’5/8. A certi fi cate as 

indicated  in  §2.1  in  compliance  with  standard  NF  EN  10204 will  be  requested  from  the  supplier  and  fi led  in  the  facility’s 

technical documentati on.

Technical data relati ve to the safety requirements of the various applicable directi ves must be indicated on the informati on 

plate. All this informati on must be recorded in the unit’s installati on manual, which must be kept in the technical fi le of the 

unit: model, code, serial number, maximum and minimum OT, OP, year of manufacture, EC label, manufacturer’s address, 

refrigerant and weight, electrical parameters, thermo-dynamic and acousti c performances

Recycling

This symbol means that your appliance must not be thrown into a normal bin. It will be selecti vely collected for the 

purpose  of  reuse,  recycling  or  transformati on.  Any  substances  it  may  contain  which  are  potenti ally  dangerous  to  the 

environment shall be eliminated or neutralised.

Request informati on on recycling procedures from your retailer.

Summary of Contents for Z300 M4

Page 1: ...H0548600 B 2016 05 Instructions for installation and use English More documents on www zodiac poolcare com Z300 PM30 EverFirst EN...

Page 2: ...er supply Do not handle the electrical elements with wet hands Clean the terminal board or the power supply socket before connection For any component or sub assembly containing a battery do not recha...

Page 3: ...with the device it is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may result in material damage or ser...

Page 4: ...front rear connectors Anti vibration studs Attachment holes Bottom view of the appliance base for attachment to the ground and location of the anti vibration studs The device must not be installed In...

Page 5: ...to work on the device water entry valve by pass valve water exit valve water entry adjustment valve optional water exit adjustment valve optional water treatment minimum distance To evacuate the conde...

Page 6: ...circuit breaker D curve for calibre see 5 2 I Technical speci cations with a 30 mA dedicated di erential circuit breaker circuit breaker or switch Additional protection may be required during installa...

Page 7: ...be controlled by remote To do so use the remote control kit available as an option For the connection consult the manual supplied with the kit 1 4 2 Heating priority option This function helps to keep...

Page 8: ...For the connection remove the shunt between terminals 7 8 and connect the switch cable in place potential free contact no polarity 220 240V 50Hz Activate the command by pressing for 5 seconds when the...

Page 9: ...son run automatic circulation for at least 12 hours day the longer this time the longer the heat pump will have enough operating range to heat up Cover the basin with a sheet bubble canopy canvas etc...

Page 10: ...alve A wide and close valve C by half Connect the power supply to the heat pump If the heat pump is on standby press for 3 seconds appears for 2 seconds then di erent software No depending on the devi...

Page 11: ...or the interface 2 languages available French and English reversible models only Select the device s operating mode Water heating only Water heating or cooling automatic according to need The light mu...

Page 12: ...intering micro cover provided on the heat pump 3 2 I Maintenance It is recommended that the device be general serviced at least on a yearly basis to ensure proper operation maintain performance levels...

Page 13: ...converted to gas If your heat pump is not in its defrost cycle this is not normal Switch o and disconnect the heat pump immediately and contact your reseller The device is not working If there is no d...

Page 14: ...Automatic if fewer than 4 faults per hour or press faults per hour Cooling circuit high pressure fault Exchanger clogged with dirt Clean the water exchanger Automatic if fewer than 4 faults per hour o...

Page 15: ...n the link cable between the boards By electricity supply disconnection or automatic if the fault disappears Board power supply fault Check the boards power supply Faulty boards Replace the boards 4 3...

Page 16: ...H0548600 B EN 2016 05 15 4 4 I Wiring diagrams 4 4 1 Z300 M4 M5 M7 PM3041 PM3051 PM3061 EverFirst 8M 11M 13M 4 4 2 Z300 T5 PM3053 EverFirst 11T...

Page 17: ...16 H0548600 B EN 2016 05 4 4 3 Z300 MD5 PM3052 EverFirst 11MD 4 4 4 Z300 MD8 PM3072 EverFirst 15MD EN...

Page 18: ...P Low pressure switch ST5 Compressor back ow sensor C1 Ventilator condenser VA Varistor C2 Compressor condenser BLU Blue C3 Filter WHT White D1 Progressive starter GRY Grey EXP VALVE Electronic regula...

Page 19: ...chnical compartment A Z300 PM30 EverFirst B 50 connector to be glued x2 C Gland D Anti vibration studs x5 E Wintering cap x2 F Wintering cover Heating priority G Remote control H Plant room kit I Cond...

Page 20: ...ge category II Nominal absorbed intensity A 7 9 10 3 4 25 13 10 4 4 16 7 4 Maximum absorbed intensity A 10 13 4 7 15 7 12 8 5 24 9 3 Minimum cable section mm 3x2 5 3x2 5 5x2 5 3x4 3x2 5 5x2 5 3x6 5x2...

Page 21: ......

Page 22: ...49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Trouvez plus d...

Reviews: