10
2.2 I Hydraulic connections
•
A by-pass must be installed to make it easier to work on the appliance.
•
The device will be connected to the pool's filtration circuit with a Ø63 or Ø75 PVC pipe (depending on the model) using
the supplied connectors, after the filter and before the water treatment. We strongly recommend the installation of a
siphon if the water treatment system inlet is located less than 25 cm below the heat pump water outlet.
•
Respect the direction of hydraulic connection.
•
As a preventive measure, we recommend that a non-return valve is added to prevent chemicals from reaching the
pump if the hydraulic circuit stops.
1.5 m *
1.5 m *
1.5 m *
1 m*
2 m*
: water inlet valve
: by-pass valve
: water outlet valve
: water inlet connector
(PVC-U union)
: water outlet connector
(PVC-U union)
(
* minimum distance
Connection to a standard filtration circuit
Information: condensate drainage
Caution, several litres of water can be drained from your appliance each day, which is related to the
condensation of moisture contained in the air. We strongly recommend connecting the drain to a suitable
water drainage system. The installation of a siphon is recommended inside the appliance to avoid stagnant
water.