background image

H0493700.A - EN - 2014-07

1

• 

Read this notice carefully before installing, maintaining or repairing this appliance!

• 

The 

 symbol  indicates important information that must be taken into consideration in order to 

avoid risk of harm to persons or damage to the appliance.

• 

The 

 symbol  indicates useful information.

  

 

 Warnings

• 

As part of a continuous improvement process our products may be modified without prior notice. 

• 

Exclusive use: regulation system for pools (must not be used for any other purpose).

• 

System designed to work with water from the public network. The use of water from wells or rain 

water is prohibited.

• 

The installer is liable for the installation of the appliance and the compliance with local regulations 

in matters of installation. Under no circumstances can the manufacturer be held liable in the event of 

failure to comply with applicable local standards. Under no circumstances shall the manufacturer be 

held liable if current local installation regulations are not followed.

• 

It is important that this equipment is operated by competent and qualified (both physically and 

mentally) people  that  have  previously received  the  instructions  for  use  (by  reading  this booklet). 

Any person not meeting these criteria should not go near the equipment, to avoid the risk of being 

exposed to dangerous components.

• 

If the equipment malfunctions: do not attempt to repair the equipment yourself – contact your 

installer.

• 

Before  working  on  the  equipment,  ensure  that  it  and  any  other  equipment  connected  to  it  are 

disconnected from the electricity supply.

• 

Before  connecting  it  to  the  electricity  supply,  check  that  the  voltage  marked  on  the  equipment 

matches the mains supply voltage.

• 

Removing or bypassing one of the safety devices automatically voids the guarantee, as does fitting 

replacement parts not manufactured by us.

• 

Incorrect installation can result in damaged equipment or serious physical injury (or even death).

• 

Keep the equipment out of the reach of children.

• 

The pH Link or Dual Link module is only designed to use pH minus (special liquid for use in swimming 

pools). Use of other products automatically voids the guarantee.

Summary of Contents for W197515

Page 1: ...H0493700 A 2014 07 Instructions for installation and use English More documents on www zodiac poolcare com ...

Page 2: ...ulations are not followed It is important that this equipment is operated by competent and qualified both physically and mentally people that have previously received the instructions for use by reading this booklet Any person not meeting these criteria should not go near the equipment to avoid the risk of being exposed to dangerous components If the equipment malfunctions do not attempt to repair...

Page 3: ... water balance 4 2 2 Installing the pH Link or Dual Link module 5 2 3 Installing the POD Kit 5 3 Use 8 3 1 Activating the module 8 3 2 Display 8 3 3 Calibrating the sensor s 8 3 4 Adjusting the set point s 9 3 5 Setting the pool volume 9 3 6 Peristaltic pump 10 4 Maintenance 10 4 1 Cleaning the sensor s 10 4 2 Wintering 11 5 Troubleshooting 11 6 Registering the product 12 7 Product conformity 12 ...

Page 4: ...ing clip PTFE tape and stoppers suction injection hose 5 meters Hole saw 22 mm 1 2 2 Dual Link module Dual Link module POD kit pH sensor ACL sensor Hole saw 22 mm Accessory bag counterweight securing clip PTFE tape and stoppers suction injection hose 5 meters Buffer solution pH 7 5 Buffer solution 700 mV 1 3 Technical specifications pH Link module Dual Link module Supply voltage Low voltage connec...

Page 5: ...ial of your pool It is essential that the pool water balance is controlled and adjusted before installing the appliance Making sure that the pool water balance is correct from the very start will reduce the likelihood of encountering problems on the first days of operation or during the season the pool is in use Even if it is an automatic control system it is essential to analyse the water regular...

Page 6: ...es particularly when performing any technical work between disconnecting the power packfrom the mains electricity supply and connecting the pH Link or Dual Link module 2 3 Installing the POD Kit The sensor holding POD Kit is a single assembly including the flow rate detector used by your appliance see 2 3 2 the pH and ACL sensors and pH minus injection The cell bypass valves must always be open Th...

Page 7: ...are still connected to their BNC cables Disconnect the cables beforehand to avoid damage Once the sensors are installed they may be connected to the BNC sockets on the power pack named pH blue and ACL red They must now be calibrated see 3 3 1 2 A badly installed sensor may give false readings and cause inappropriate operation of the appliance Neither the manufacturer nor the unit shall be liable i...

Page 8: ...ertight before operating the pH Link or Dual Link module Replace the protective cover on the peristaltic pump 2 3 2 Installing the flow switch 2 positions possible After the upstream valve if the cell is in by pass 1 On the POD kit if the cell is inline 2 a pH Link or Dual Link module installed at the same time as the power pack Locate the flow switch supplied with the power pack Screw the flow sw...

Page 9: ...calibrating at least once every 2 months during the period the swimming pool is being used Ensure the sensors are cleaned before calibration see 4 1 Confirm that the power pack is plugged in Stop the pool pump and isolate the sensors by closing any valves so as to be able to remove the sensors safely Disconnect the BNC cable from the top of each sensor then remove them unscrew from the POD Then re...

Page 10: ...f disinfection potential in the water The ACL set point required to reach the optimum chlorine level is different in every swimming pool A period manual measurement of free chlorine level in the pool is therefore necessary to adjust this ACL set point To increase the chlorine production potential increase the ACL set point To decrease the chlorine production potential decrease the ACL set point Du...

Page 11: ...the peristaltic pump more quickly it may be necessary to repeat these steps several times depending on the length of the pH minus feed line 3 6 2 Activating deactivating the peristaltic pump For safety reasons the peristaltic pump is not activated when delivered When the pH Link or Dual Link module is connected to the power pack the peristaltic pump is programmed to start approximately about 8 hou...

Page 12: ...ize PH ERROR pH adjustment has performed 5 cycles without reaching its set point 10 hours Check the pH in the pool Calibrate or replace the pH sensor The pH minus container is empty Replace the container The peristaltic pump is not primed Test the peristaltic pump The pH sensor is dirty out of calibration or not working Clean and calibrate the sensor Replace the pH7 5 buffer solution if necessary ...

Page 13: ...irst to be informed of new Zodiac products and special offers You can help us to constantly improve our product quality Europe Rest of the World www zodiac poolcare com America www zodiacpoolsystems com Australia Pacific www zodiac com au 7 Product conformity This appliance has been designed and built according to the following standards EN6000 6 1 2006 EN6000 6 3 2007 IEC 61558 2 6 1997 AS NZ 313...

Page 14: ...ease contact your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac Pool Care Europe BP 90023 49180 St Barthélémy d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS ...