background image

H03609

00.B1.EN

 

 

2012/01

 

 

2

 

Summary

 

 

1.

 

Information

 

before

 

installation

 

.......................................................................................................

 

2

 

1.1

 

General

 

terms

 

of

 

delivery,

 

storage

 

and

 

transport

 

........................................................................................................

 

2

 

1.2

 

Content

 

.........................................................................................................................................................................

 

2

 

1.3

 

Operating

 

conditions

 

....................................................................................................................................................

 

2

 

1.4

 

Technical

 

specifications

 

................................................................................................................................................

 

2

 

2.

 

Installation

 

......................................................................................................................................

 

3

 

2.1

 

Selecting

 

an

 

installation

 

site

 

.........................................................................................................................................

 

3

 

2.2

 

Hydraulic

 

connections

 

...................................................................................................................................................

 

3

 

2.3

 

Electrical

 

connections

 

...................................................................................................................................................

 

3

 

3.

 

Use

 

.................................................................................................................................................

 

4

 

3.1

 

Presentation

 

of

 

the

 

regulation

 

......................................................................................................................................

 

4

 

3.2

 

Starting

 

the

 

device

 

........................................................................................................................................................

 

4

 

3.3

 

Checks

 

to

 

be

 

carried

 

out

 

after

 

operating

 

for

 

a

 

few

 

moments

 

......................................................................................

 

5

 

3.4

 

Winter

 

storage

 

..............................................................................................................................................................

 

5

 

4.

 

Maintenance

 

...................................................................................................................................

 

5

 

4.1

 

Maintenance

 

instructions

 

.............................................................................................................................................

 

5

 

4.2

 

Recycling

 

.......................................................................................................................................................................

 

5

 

5.

 

Resolution

 

of

 

problem

 

....................................................................................................................

 

5

 

5.1

 

Malfunctions

 

of

 

the

 

device

 

...........................................................................................................................................

 

5

 

5.2

 

Fuse

 

replacement

 

.........................................................................................................................................................

 

6

 

5.3

 

FAQ

 

...............................................................................................................................................................................

 

6

 

5.4

 

Modification

 

of

 

the

 

maximum

 

setpoint

 

temperature

 

..................................................................................................

 

6

 

6.

 

Product

 

registration

 

........................................................................................................................

 

6

 

7.

 

Conformity

 

certificate

 

.....................................................................................................................

 

6

 

 

 

Available

 

in

 

appendix

 

at

 

the

 

end

 

of

 

the

 

manual:

  

wiring

 

diagrams

 

dimensions

 

and

 

description

 

 

 

1.

 

Information

 

before

 

installation

 

 

1.1

 

General

 

terms

 

of

 

delivery,

 

storage

 

and

 

transport

 

 

Any

 

equipment,

 

even

 

carriage

 

and

 

packing

 

free,

 

travels

 

at

 

the

 

consignee's

 

risk.

 

The

 

consignee

 

shall

 

make

 

reservations

 

in

 

writing

 

on

 

the

 

carrier's

 

bill

 

of

 

lading

 

if

 

damage

 

is

 

detected,

 

caused

 

during

 

transport

 

(confirmation

 

to

 

be

 

sent

 

to

 

the

 

carrier

 

within

 

48

 

hours

 

by

 

registered

 

mail

 

with

 

acknowledgement

 

of

 

receipt).

 

 

1.2

 

Content

 

 

 

 

Ø63

 

 

Ø50

 

 

X1

 

X2

 

X2

 

X2

 

 

1.3

 

Operating

 

conditions

 

 

Operating

 

range:

 

water

 

temperature

 

of

 

between

 

2

 

°C

 

and

 

40

 

°C

 

 

1.4

 

Technical

 

specifications

  

 

Red

 

Line

 

+

 

Unit

 

3

 

6

 

9

 

12

 

Power

 

*

 

kW

 

3

 

6

 

9

 

12

 

Power

 

supply

 

Single

phase

 

230V

 

X

 

X

 

X

 

 

Three

phase

 

400V

 

X

 

X

 

X

 

X

 

*

 

with

 

a

 

manufacturer

 

tolerance

 

of

 

±5%

 

 

protection

 

rating:

 

IP

 

45

 

 
 
 
 
 

Summary of Contents for RED LINE

Page 1: ...EN Instructions for installation and use English H03609 00 B 2012 01 ...

Page 2: ...ay occur as a result of failure to comply with local standards pertaining to installation This appliance must be handled by competent and qualified personnel physically and mentally who are familiar with the operating instructions by reading the user guide Persons who do not satisfy these requirements must not handle the device so as to avoid exposure to potentially dangerous parts If the device m...

Page 3: ...t temperature 6 6 Product registration 6 7 Conformity certificate 6 Available in appendix at the end of the manual wiring diagrams dimensions and description 1 Information before installation 1 1 General terms of delivery storage and transport Any equipment even carriage and packing free travels at the consignee s risk The consignee shall make reservations in writing on the carrier s bill of ladin...

Page 4: ...m h it is recommended to use a by pass as this makes maintenance of the appliance simpler on the swimming pool filtration circuit after the filter and before any water treatment unit Check the tightening of the hydraulic connections and for leaks Red Line Hydraulic circuit pressure Connections Minimum water flowrate Maximum water flowrate test service 3 6 9 12 4 bars 2 bars Ø63 or Ø50 5 m h 30 m h...

Page 5: ...3 1 Presentation of the regulation 3 2 Starting the device Fully open valves 2 and 3 and close valve 1 see 2 2 if installed Start the filtration pump Check that there is no air in the circuit Check that the water flow rate is between 5 and 30m h If it is above 30m h adjust valve 1 so as to obtain 30m h maximum Turn on control unit power then start it Adjust the setpoint temperature display and mod...

Page 6: ...ician Check the electrical components Check the ground connection Check that the electric cable connections are properly tightened and that the electric box is clean 4 2 Recycling This symbol means that your device must not be thrown in the bin The device must be collected by a selective system in view of re use recycling or similar Any substances it may contain which are potentially dangerous to ...

Page 7: ...lator the on indicator light goes off the pool water temperature is displayed Simultaneously press and hold and for 5 seconds PA is displayed Press Then enter the value 80 using the or keys access code to the settings menu Press to confirm this code PA is displayed Simultaneously press and hold the and keys for 5 seconds Press to scroll through each parameter until r2 is displayed Press the curren...

Page 8: ...H03609 00 B1 EN 2012 01 1 Wiring diagram Red Line 3 6 9 kW single phase and three phase Red Line 12 kW three phase ...

Page 9: ...p KM1 power contactor TS safety thermostat positive triggering at 63 C manual reset GN GG black or grey sheath CN Black cable with clips of colours V j green yellow B blue M brown Bl white N black Ro red Vi violet Ground Description 1 Controller 2 flow switch 3 cable crossing 4 Preheater body 5 union Ø63 50 fittings 6 safety thermostat positive 7 power contactor 8 connection terminal 9 Heating ele...

Page 10: ...H03609 00 B1 EN 2012 01 3 Dimensions Red Line A B weight mm mm Kg 3 6 538 452 3 5 9 12 638 552 4 ...

Page 11: ...Notes ...

Page 12: ...ct your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barthélémy d Anjou cedex France S A S U au capital de 517 200 SIREN 395 068 679 RCS PARIS Plaque signalétique Product name plate ...

Reviews: