background image

1

 WARNINGS

GENERAL WARNINGS

• Failure to respect the warnings may cause serious damage to the pool equipment 

or cause serious injury, even death.

• 

Only a person qualified in the technical fields concerned (electricity, hydraulics or 

refrigeration)  is  authorised  to  perform  this  procedure.  The  qualified  technician 

working  on  the  appliance  must  use/wear  personal  protective  equipment  (such 

as safety goggles and protective gloves, etc.) in order to reduce the risk of injury 

occurring when working on the appliance.  

• 

Before handling the machine, ensure that it is switched off and isolated.

• 

The appliance is intended to be used with pools for a specific purpose; it must not 

be used for any purpose other than that for which it was designed.

• 

This appliance is not intended for use by children.

• 

This  appliance  is  not  intended  for  use  by  individuals  (including  children,  over 

the age of 8) lacking in experience or with impaired physical, sensory or mental 

capabilities, unless:

  - they receive supervision and are instructed on how to use the appliance by a 

person responsible for their safety; and

  - they understand the hazards involved.

• 

Children must be supervised to ensure that they do not play with the appliance.

• 

The appliance must be installed according to the manufacturer’s instructions and 

in compliance with local standards in force. The installer is responsible for installing 

the appliance and for compliance with national installation regulations. Under no 

circumstances may the manufacturer be held liable in the event of failure to comply 

with applicable local installation standards.

• 

For any work other than the simple user maintenance described in this manual, the 

product should be referred to a qualified professional.

• 

Incorrect installation and/or use may cause serious damage to property or serious 

injuries (possibly causing death). 

• All equipment, even postage and packing paid, travels at the risks and perils of the 

recipient. The latter shall issue reserves in writing on the carrier's delivery slip if 

damage is detected, caused during transport (confirmation to be sent to the carrier 

within 48 hours by registered letter). In the event that an appliance containing 

refrigerant has been turned on its side, mention your reservations in writing to the 

carrier.

• 

If the appliance suffers a malfunction, do not try to repair it yourself; instead contact 

a qualified technician.

• 

Refer to the warranty conditions for details of the permitted water balance values 

for operating the appliance.

• 

Deactivating, eliminating or by-passing any of the safety mechanisms integrated 

into the appliance shall automatically void the warranty, in addition to the use of 

spare parts manufactured by unauthorised third-party manufacturers.

• 

Do not spray insecticide or any other chemical (flammable or non-flammable) in 

the direction of the appliance, as this may damage the body and cause a fire.

• 

Do not touch the fan or moving parts and do not place a rod or your fingers in the 

vicinity of the moving parts during operation of the appliance. Moving parts can 

cause serious injury or even death.

EN

Summary of Contents for PSA Red Line 12

Page 1: ...Installation and user manual English Electric heater Translation of the original instructions in French H0360900_REVC 2020 02 More documents on www zodiac com EN...

Page 2: ...ons Under no circumstances may the manufacturer be held liable in the event of failure to comply with applicable local installation standards For any work other than the simple user maintenance descri...

Page 3: ...power supply when in operation Do not pull on the power cord to disconnect it from the power supply If the power cord is damaged it must be replaced by the manufacturer an authorised representative or...

Page 4: ...llation and user manual as well as the warnings and warranty booklet delivered with the appliance Failure to do so may result in material damage or serious or fatal injury and will void the warranty K...

Page 5: ...ctor x2 C 50 connector x2 D Joint x2 1 2 I Technical specifications Red Line Unit 3 6 9 12 Power kW 3 6 9 12 Power supply 230V single phase 400V three phase with manufacturer tolerance 5 Protection in...

Page 6: ...Heater body union PVC connector 63 50 Overheat control Power contactor Supply terminal block Resistor Screw thimble regulation sensor Screw thimble safety thermostat sensor Red Line 3 6 9 12 Weight k...

Page 7: ...alled at the low point after the heater to prevent chlorine from flowing back into the heater Comply with the direction of installation If this is not complied with see diagram opposite the flow switc...

Page 8: ...ulated against any cutting or hot elements that may damage or crush it Check that the power cord is firmly attached to the connection terminal board 12 kW Red Line units are wired via three phase syst...

Page 9: ...t the water flow rate is between 5 and 30 m h If the flow rate exceeds 30 m h adjust valve 1 V1 to reach 30 m h maximum Check that there is no air in the circuit Connect the regulation system to the p...

Page 10: ...switch box Troubleshooting If a problem occurs before you contact your retailer please carry out these few simple checks using the following tables If the problem continues contact your retailer 5 1...

Page 11: ...ostat with digital display F1 3 15 A T protection fuse CD Flow switch So Pool water regulation sensor PTC R Resistor capacity engraved on the metal cup KM1 Power contactor TS Overheat control triggere...

Page 12: ...F1 3 15 A T protection fuse CD Flow switch So Pool water regulation sensor PTC R Resistor capacity engraved on the metal cup KM1 Power contactor TS Overheat control triggered at 63 C manual reset GN...

Page 13: ...23 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d...