BUOYANCY MECHANISM - Pressure
II -4-1- Buoyancy mechanism inflation
•
Place the adapter corresponding to the diameter of the semi built-in valve at the inflator
hose nozzle.
Inflate the buoyancy mechanism,
balancing the pressure between the different
compartments until the partitions (a) are no longer visible (pressure = 240 mb)
Never pressurise a
compartment when the
others are completely
deflated
a
100 %
0 %
0 %
1
50 %
50 %
50 %
2
100 %
100 %
100 %
Inflating is complete:
Screw on the inflating valve caps
NOTE
:
A slight air leak is normal before the valve cap is screwed on
Only the caps guarantee final air tightness
II-4-2- Pressure
Operating pressure for the buoyancy mechanism is 240 mb/ 3.4 PSI
(middle of the green
zone of the pressure gauge).
Your boat is equipped with an
ACCESS
pressure indicator that will enable you to read the
pressure quickly and efficiently during inflating (see explanations for use in the section
Inflating System).
The ambient temperature of the air or
Ambient Temperature
Internal buoyancy
mechanism pressure
water proportionately influences the
+1°C
+4 mb / 0.06 PSI
level of internal pressure in the
buoyancy mechanism
-1°C
-4 mb / 0.06 PSI
Summary of Contents for PRO 850
Page 2: ...Page 1 48 F R A N C A I S Manuel du Propri taire Tome 2...
Page 7: ...Page 6 48 ATTENTION NE PAS UTILISER DE NETTOYANT AGGRESSIF A BASE DE SOLVANT COMME L ACETATE...
Page 48: ...Page 47 48 F R A N C A I S...
Page 49: ...Page 48 48 EMPLACEMENT ACCESSOIRES OPTIONNELS VI 1 6 Position accessoire T TOP...
Page 98: ...47 47 E N G L I S H...
Page 105: ...Pagina 5 47 E S P A O L...
Page 147: ...Pagina 47 47 E S P A O L POSICI N ACCESORIOS OPCIONALES VI 6 Posici n del accesorio T TOP...
Page 195: ...Pagina 46 di 46 POSIZIONAMENTO DEGLI ACCESSORI OPTIONAL VI 1 6 Posizione accessorio T TOP...
Page 244: ...Seite 47 47 D E U T S C H EINBAUSTELLEN DES OPTIONALEN ZUBEH RS VI 1 6 Einbaustelle T TOP...