16
Indic
at
or ligh
ts
Description
Steady
Flashing
Off
"HEATING" mode
Operating in "HEATING"
mode
Time delay
Mode disabled
"COOLING" mode
Operating in "COOL
-
ING" mode
Time delay
Mode disabled
"HEATING & COOLING"
mode
Operating in "HEATING
& COOLING" mode
Time delay
Mode disabled
Alarm
Alarm enabled
/
Disabled
Padlock
Keypad locked
/
Keypad unlocked
"TIMER"
"TIMER" programming
enabled
/
Disabled
"TIMER" start time
Configuration in
progress
/
/
"TIMER" stop time
Configuration in
progress
/
/
°F
°C
Celsius/Fahrenheit
Selected temperature
unit
/
/
Information: appliance display on stand-by (powered on and switched off)
•
The screen lighting fades and the indicators
("HEATING" mode),
("COOLING" mode)
and
("HEATING & COOLING" mode) are switched off.
2.3 I Operation
•
Check that there are no tools or other foreign objects in the machine,
•
Refit the panel providing access to the technical part (see § "5.3 I Dimensions and marking"),
•
Set the valves as follows: valve B wide open, valves A, C, D and E closed.
: water inlet
valve
: by-pass valve
: water outlet
valve
: water inlet
adjustment valve (optional)
: water outlet
adjustment valve (optional)
• An incorrect by-pass setting may cause the heat pump to malfunction.
•
Check that the hydraulic connections are correctly tightened and that there are no leaks.
•
Check that the appliance is stable.
•
Turn on the water flow (by activating filtration).
•
Close valve B gradually so that the filter pressure is increased by 150g (0.150 bars).
•
Open valves A, C and D fully then valve E by half (the air which has built up in the heat pump condenser and the
filtration circuit will bleed out). If valves D and E are not present, open valve A wide and close valve C by half.
•
Connect the power supply to the heat pump
.
•
The heat pump is on standby.
•
Press and hold for 5 seconds to turn on the heat pump
.
•
Set the desired temperature (called the "temperature setpoint" ) (see § "2.4.2 Changing operating mode").
After the start-up steps for your heat pump:
•
Shut down the water circulation temporarily (by stopping the filtration or closing valve B or C) to check that your
appliance stops after a few seconds (via the activation of the flow switch)
.
•
Reduce the temperature setpoint to below the water temperature to check that the heat pump stops operating.
•
Switch off the heat pump by pressing and holding for 5 seconds and check that it stops
.
Summary of Contents for PM40 Series