background image

Page 5 

English

  

 

Jandy

®

 Pro Series, Slide Valve & Backwash Valve   

|

   Installation & Operation Manual

Figure 4.   Jandy Versa-Coupler

Figure 3.  sVlV8 installed on Jandy dEl48 or 

(dEl60)

7. 

Place filter and valve in proper location on the 

equipment set pad.

8. 

Plumb the discharge of the pump into the Slide 

Valve inlet labeled 

PORT B.

9. 

Plumb the Slide Valve outlet labeled 

PORT A

 to 

the heater or pool return lines.

10.  Plumb the Slide Valve outlet labeled 

PORT E

 to 

the waste line as needed. Allow the connections to 

dry for 24 hours.

CAUTiOn

Do not let any adhesive get inside the Slide Valve 

body. Adhesive inside the valve body will prevent the 

piston from moving freely, or cause the valve to leak.

CAUTiOn

To avoid costly equipment damage, after verifying 

proper water flow and prior to putting system into 

normal operating conditions, flush the system using 

Backwash mode until the waste water is clean. Refer 

to Section 4 for Backwash mode operation instructions.

11.  When the glue is dry, start the system and check 

for proper water flow.

nOTE

  For new installations other than Jandy Pro Series 

DEL48 or DEL60, use the SVLV2 and the Versa 

Coupler Kit, p/n 8044. See Figure 4.  

 

If using the Slide Valve with a Pentair® filter, use 

Pentair Pool Products® Union Set #27002, and then 

proceed to Section 2. If using a Sta-Rite® filter, use 

Sta-Rite® Union Set #PKGM188, and then proceed to 

Section 2.

section 3.  sVlV2 and Versa-

Coupler installation

nOTE

  Certain filters may require only one (1) versa-coupler 

(p/n 8044).

1. 

Slide one (1) versa-coupler into 

PORT C

 and one 

(1) into 

PORT D

 on the Slide Valve.

2. 

Hold the Slide Valve up to the filter and twist the 

versa-couplers until they slide into the filter inlet 

and outlet ports.  

nOTE

  Make sure to align each versa-coupler to the filter and 

the Slide Valve prior to gluing the assembly. When 

the parts are in alignment, mark each piece to ensure 

correct reassembly.

3. 

Remove the valve from the filter. Clean the versa-

couplers and glue them onto the valve using the 

alignment marks as a reference.

4. 

Clean the versa-coupler and glue onto the filter. 

Hold the coupler in place for a minimum of one 

(1) minute.

5. 

Plumb the discharge of the pump into the Slide 

Valve inlet labeled 

PORT B.

nOTE

  Refer to Figure 5 for Steps 6 and 7. 

6. 

(Jandy Pro Series DEL, DEV, and JS series 

Filters)

 Plumb the Slide Valve outlet labeled 

PORT A

 to the heater or pool return lines.

 

(Other Manufacturers Filters with the filter top 

port as the inlet)

 Plumb the Slide Valve outlet 

labeled 

PORT E

 to the heater or pool return lines.

7. 

(Jandy Pro Series DEL, DEV, and JS series 

Filters)

 Plumb the Slide Valve outlet labeled 

PORT E

 to the waste line as needed. 

 

(Other Manufacturers Filters with the filter top 

port as the inlet)

 Plumb the Slide Valve outlet 

labeled 

PORT A

 to the waste line as needed. 

8. 

Allow the connections to dry for 24 hours.

9. 

When the glue is dry, start the system and check 

for proper water flow.

To Pool

(PORT A)

To Waste (PORT E)

From

Pump

(PORT B)

To Filter Body 

(cut away view)

Filter Outlet

 (PORT C)

Filter inlet

 (PORT d)

Versa-

Coupler  

p/n 8044

Alignment 

Mark

Summary of Contents for Jandy Pro Series

Page 1: ...oduct read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Imprope...

Page 2: ...le of Contents Section 1 Safety Information 3 Section 2 SVLV8 Installation 4 Section 3 SVLV2 and Versa Coupler Installation 5 Section 4 Normal Operation 6 Section 5 Backwash Mode 6 Section 6 Servicing...

Page 3: ...sult in death serious personal injury or property damage Be sure all air is out of system before operating or testing the equipment WARNING To minimize risk of severe injury or death the filter and or...

Page 4: ...ration mode fully extend the valve handle See Figure 1 Section 2 SVLV8 Installation 1 Remove the Slide Valve from the packaging Twist the handle on the Slide Valve several times to verify that the pis...

Page 5: ...tain filters may require only one 1 versa coupler p n 8044 1 Slide one 1 versa coupler into PORT C and one 1 into PORT D on the Slide Valve 2 Hold the Slide Valve up to the filter and twist the versa...

Page 6: ...2 Open the air release valve on top of the filter tank to release all pressure from inside the tank and system Wait for all the air to evacuate the system 3 Jandy Pro Series DEL DEV and JS series Filt...

Page 7: ...e filter when there is pressurized air in the system Starting the pump while there is any pressurized air in the system can cause the filter lid to be blown off which can cause death serious personal...

Page 8: ...at there is no water left in the valve place the shaft back into the Slide Valve and tighten the lid union nut 7 Position the Slide Valve in Backwash mode See Section 4 Jandy DEL DEV and JS series Fil...

Page 9: ...ash Valve Installation Operation Manual Figure 10 Slide Valve Head Loss Curve Slide Valve with DE Filter Data Shown 0 0 2 3 4 6 6 9 9 2 11 5 0 50 100 25 75 125 Flow Rate GPM Design Head Loss Feet Head...

Page 10: ...andle 1 1 Roll Pin Shaft 13 16 1 Index Plate Lid 1 2 Rebuild Kit O rings Roll Pins and Index Plate Lid BWVL SLD R0473000 O ring Lid 1 O ring Shaft Top Black 1 O ring Shaft Bottom Purple 1 O ring Union...

Page 11: ...Page 11 ENGLISH Jandy Pro Series Slide Valve Backwash Valve Installation Operation Manual 1 2 3 4 3 4 3 4 1 2 3 1 2 3 4 1 2 3 1 2 3 4 3 1 2...

Page 12: ...1 800 822 7933 www ZodiacPoolSystems com ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks referenced herein are the property of their respective owner...

Reviews: