Page 5
English
Jandy
®
Pro Series, Slide Valve & Backwash Valve
|
Installation & Operation Manual
Figure 4. Jandy Versa-Coupler
Figure 3. sVlV8 installed on Jandy dEl48 or
(dEl60)
7.
Place filter and valve in proper location on the
equipment set pad.
8.
Plumb the discharge of the pump into the Slide
Valve inlet labeled
PORT B.
9.
Plumb the Slide Valve outlet labeled
PORT A
to
the heater or pool return lines.
10. Plumb the Slide Valve outlet labeled
PORT E
to
the waste line as needed. Allow the connections to
dry for 24 hours.
CAUTiOn
Do not let any adhesive get inside the Slide Valve
body. Adhesive inside the valve body will prevent the
piston from moving freely, or cause the valve to leak.
CAUTiOn
To avoid costly equipment damage, after verifying
proper water flow and prior to putting system into
normal operating conditions, flush the system using
Backwash mode until the waste water is clean. Refer
to Section 4 for Backwash mode operation instructions.
11. When the glue is dry, start the system and check
for proper water flow.
nOTE
For new installations other than Jandy Pro Series
DEL48 or DEL60, use the SVLV2 and the Versa
Coupler Kit, p/n 8044. See Figure 4.
If using the Slide Valve with a Pentair® filter, use
Pentair Pool Products® Union Set #27002, and then
proceed to Section 2. If using a Sta-Rite® filter, use
Sta-Rite® Union Set #PKGM188, and then proceed to
Section 2.
section 3. sVlV2 and Versa-
Coupler installation
nOTE
Certain filters may require only one (1) versa-coupler
(p/n 8044).
1.
Slide one (1) versa-coupler into
PORT C
and one
(1) into
PORT D
on the Slide Valve.
2.
Hold the Slide Valve up to the filter and twist the
versa-couplers until they slide into the filter inlet
and outlet ports.
nOTE
Make sure to align each versa-coupler to the filter and
the Slide Valve prior to gluing the assembly. When
the parts are in alignment, mark each piece to ensure
correct reassembly.
3.
Remove the valve from the filter. Clean the versa-
couplers and glue them onto the valve using the
alignment marks as a reference.
4.
Clean the versa-coupler and glue onto the filter.
Hold the coupler in place for a minimum of one
(1) minute.
5.
Plumb the discharge of the pump into the Slide
Valve inlet labeled
PORT B.
nOTE
Refer to Figure 5 for Steps 6 and 7.
6.
(Jandy Pro Series DEL, DEV, and JS series
Filters)
Plumb the Slide Valve outlet labeled
PORT A
to the heater or pool return lines.
(Other Manufacturers Filters with the filter top
port as the inlet)
Plumb the Slide Valve outlet
labeled
PORT E
to the heater or pool return lines.
7.
(Jandy Pro Series DEL, DEV, and JS series
Filters)
Plumb the Slide Valve outlet labeled
PORT E
to the waste line as needed.
(Other Manufacturers Filters with the filter top
port as the inlet)
Plumb the Slide Valve outlet
labeled
PORT A
to the waste line as needed.
8.
Allow the connections to dry for 24 hours.
9.
When the glue is dry, start the system and check
for proper water flow.
To Pool
(PORT A)
To Waste (PORT E)
From
Pump
(PORT B)
To Filter Body
(cut away view)
Filter Outlet
(PORT C)
Filter inlet
(PORT d)
Versa-
Coupler
p/n 8044
Alignment
Mark