5.4.4 "Cover" mode
If the pool is equipped with a compatible electric shutter (contact closed = shutter closed), it can be connected to the
appliance in order to automatically reduce chlorination when closed. This is known as "
Cover"
mode. Chlorination will
resume at the level determined by the programmes on opening the compatible electric shutter.
Production in
"Cover"
mode can be configured in the settings of the main menu from
"Low/Cover"
mode.
"Low/Cover"
mode can be configured from 0% to 30% in intervals of 10%. The programmes remain active when the
appliance is in
"Low/Cover"
mode.
Check that the shutter is compatible and is connected to the appliance
on the low-voltage circuit, see
“2.5 I
Electrical connections”
.
"Cover"
mode is automatically activated when the shutter is closed. The message
"Cover"
mode and the production rate
are displayed on the screen.
"Cover"
mode will end as soon as the shutter is completely open.
If the appliance is equipped with a Dual Link module, we recommend not connecting
"Cover"
mode. More specifically,
chlorination is managed by the Dual Link module. In cases where
"Cover"
mode is connected in the presence of a Dual
Link module, chlorination will be performed when the shutter is closed, even if the ORP measurement is greater than
the setpoint value.
5.4.5 "Cold water" safeguard
In addition to displaying the water temperature, the temperature sensor is used to protect the cell, which is sensitive to
cold water (reduced conductivity between the plates and thus an increase in voltage).
The temperature displayed in the top left corner of the home screen starts to flash at 15°C.
When the water temperature is less than or equal to 15°C, chlorine production automatically switches to the rate defined
in
"Low"
/
"Cover"
mode (between 0 and 30%).
When the water temperature is less than or equal to 10°C, chlorine production stops. The absence of chlorination at this
temperature is not an issue since bacterial development is slowed in cold water.
In addition to the flashing temperature display, the message
"LOW TEMPERATURE"
is displayed intermittently.
When the temperature rises to above 10°C, the production rate is set to
"Low"
/
"Cover"
When the temperature rises to above 15°C, chlorination is resumed at the operating rate set via the programmes.
5.4.6 Locking the interface
The appliance can be locked, which deactivates the buttons on the user interface panel. Press both buttons
and
simultaneously for 3 seconds. This function can be accessed from any screen/menu.
Locking the appliance automatically redirects the user to the home screen. Press both buttons
and
simultaneously
for 3 seconds to unlock the appliance.