Main advantages offered by this function: 

- a guarantee that the heat pump operates long enough to attain the required temperature, in 
particular during initial warm-up periods (no longer necessary to manually switch on the filter system 
24h/24). 
- constant control and monitoring of the pool heating requirements, even when the filter system has 
been switched off by the timer.  

 

Connection of the “priority heating” function:

 

to use terminals 16 and 17 to come to control the pump of 

filtration using the dry contact (I max. = 5 has

 

under 230Vac with circuit of class AC1 and I max. = 1,2A 

under 230Vac with circuit of class AC3), see diagram hereafter.

 

 

 

 

 

 

“Priority heating” wiring and operating diagram:  

 

 

 

 

 

A1-A2: supply to power contactor coil

 

of the filtering pump 

 filter timer 

 power contactor (3-pole or 2-pole), supplying the filter pump 

 connection cable, wire gauge 2 x 1.5 mm² minimum (service voltage 300Vac) 

 controller board with “priority heating” output, terminals 16-17 

 

heat pump B1 regulation electronic card (see placing § “dimensions and description” in the appendix) 

 

 

 
 
 
 
 

Never power the filter pump motor directly through terminals 16-17 located on plate 

Terminals 16-17 may remain live even if the heat pump is disconnected from the power 
source. 
Before performing any work on the machine, cut off the power to the filter timer at its 
circuit breaker (F on the diagram above). 

Incorrect connection of terminals 16-17 may damage the regulator and renders the 
warranty invalid.  

The minimum wire gauge for connection of the priority heating function is: 2x1.5 mm², 
of type RO2V or equivalent in countries outside the European Community, and with an 
outer diameter between 8 and 13 mm.  
Remove the plug (upper the cable gland) and fit the cable gland for passage of the 
cable into the unit.  
Once the cable is inserted in this stuffing box, block it by pulling lightly on the cable to 
retract it one centimeter. 

The cable used for priority heating and the electrical power supply cable must be strapped 
together inside the unit until just after the stuffing box. 

 

Phase 

Phase 

Neutral 

Summary of Contents for FP 8M

Page 1: ...Installation instructions PF 6M 8M 11M 13M 15M Heat pump for swimming pools R f N C 014 A EN Ver 12 2010...

Page 2: ...0 2 1 Statuses and faults of the regulator 10 2 1 1 Statuses 10 2 1 2 Faults 10 2 1 3 Display the values of sensors ST1 ST2 ST3 and ST4 11 2 2 Malfunctions of the appliance 11 2 2 1 The appliance does...

Page 3: ...ing If the appliance has been tipped over express reserves in writing to the transporter Elimination or shunting of one of the safety leads automatically to the cancellation of the guarantee as for th...

Page 4: ...1 with an ambient air of 15 C and a pool water of 26 C humidity 70 in compliance with the French NF 414 standard unit protection class IP 24 refrigerant gas R410A refrigerant charge see product name...

Page 5: ...4 3 Installing the appliance installed the 5 anti vibration studs supplied see 1 1 2 put onto a stable solid concrete slab type and level surface preserve from risks of flooding due to condensation p...

Page 6: ...5 1 1 Condensation drainage Caution your appliance can drain several litres of water per day and you are strongly advised to connect the drainage to the sewer connect a 18 interior pipe not supplied...

Page 7: ...ing function Objective to keep the pool water at the required temperature independent of the filtering time the heat pump triggers the operation of the filter every hour the pool temperature required...

Page 8: ...ing output terminals 16 17 heat pump B1 regulation electronic card see placing dimensions and description in the appendix Never power the filter pump motor directly through terminals 16 17 located on...

Page 9: ...pressure to 150 g 0 150 bar open valves 2 3 and 4 completely then half open valve 5 see 1 4 4 the air accumulated in the heat pump condenser unit and in the filter circuit is then evacuated If valves...

Page 10: ...by mode by pressing and holding for 3 seconds on then appears on the screen for 5 seconds before a small red dot appears open the valve 1 close valves 2 and 3 and open valves 4 and 5 if present ensur...

Page 11: ...ect the sensor Switch the power supply off or press if dSA flashes Defrost sensor fault ST3 Sensor defective or disconnected terminals 4 6 of the plate B1 Replace or reconnect the sensor Switch the po...

Page 12: ...an approved technician to check for the presence of an adequate quantity of refrigerant gas in the appliance Switch the power supply off or press if dtd flashes case after stand by following regulator...

Page 13: ...if the outside temperature is lower than 12 C The evaporator is fouled Clean the evaporator 2 2 4 The heat pump trips out or attempts to start itself from time to time Causes Verification solution Th...

Page 14: ...es Shipping expenses for the repaired or replaced Products delivered to the client will be borne by us excluding any labour costs travel and or accommodation expenses incurred as the result of repairs...

Page 15: ...l installer excluding installation via retrofit kit for a period of two years starting from the date mentioned on the invoice as issued by our Client to the end User Users are also required to have an...

Page 16: ...itrogen brazing etc all brazing work must be carried out by a qualified brazer welder in the case of units filled with R410A refer to the specific indications in the installation instructions this uni...

Page 17: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Page 18: ...1 Electric diagram PF 6M 8M...

Page 19: ...2 PF 11M 13M 15M...

Page 20: ...Water flow adjusting probe NTC Regulation electronic card Pump control Fuse 3 15A T 250V 5 20 Fan capacitor Compressor capacitor Fan connector Fan Compressor Soft starter Black Blue Brown Grey White...

Page 21: ...English Base Front pannel cowl Technical door Back pannel Post Grid Regulator 1 water pool inlet 1 water pool outlet Evaporator Stuffing box B1 regulation electronic card Fuse F1 Supply terminal boar...

Page 22: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Page 23: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Page 24: ...023 49180 Saint Barth l my d Anjou cedex France www zodiac poolcare com Innovative pool products and services Produits et services innovants pour la piscine Votre installateur Your installer Plaque si...

Reviews: