H0538700.
B
- EN - 2015-09
3
1. Information before installing
1.1 General delivery terms and conditions
All equipment, even postage and packing paid, travels at the risks and perils of the recipient. Written reserves should be
made on the transporter’s delivery documents if damage during transport is discovered by the recipient (confirmed by
registered letter to the transporter within 48 hours).
1.2 Contents
FloPro™ e3
Ø63/50 mm union couplings
x1
x2
1.3 Technical specifications
•
Power supplied: 1.0 HP - 750 W
•
Mains power supply: 230 Vac - 50 Hz
•
Operation from 1000 to 2850 rpm (set in ranges of 50 rpm)
• Number of programmable speeds: 3
•
Maximum rate at 8 metres from a water column: 18 m³/h
•
Operating temperatures: from 2 to 50°C air and 2 to 35°C water
•
Protection index: IPX5
2. Installation
2.1 Selecting the location
• The pump must be installed:
-
before the filter, a heating and/or water treatment system,
-
at a minimum distance of 3.5 metres from the edge of the pool, to avoid any water being sprayed onto the equipment.
Some standards allow for other distances. Refer to the regulations in effect in the country of installation.
-
ideally 30 cm below the water level,
-
out of an area subject to flooding, or on a base with drainage,
-
in a ventilated space to enable it to cool down.
• The pump must not be installed:
-
in an area subject to splashing or rain.
-
more than 1 m above the water level.
-
near a heat source or flammable gas.
•
Fit a non-return valve if the filter is installed above the water level.
•
Fit suction and discharge isolation valves if the pump is installed below the water level.
•
Easy access is required for maintenance work on the equipment.
•
Use as few elbow joints as possible.
2.2 Positioning the equipment
•
Place on a stable, solid (e.g. concrete floor) and level surface.
•
If necessary, use the bases (2 types of base, not supplied, available as an option) to raise the pump to the level of the
existing pipes.
•
Screw the pump to the ground using the adapted foundation bolt.
Summary of Contents for FloPro e3