background image

H0548600.B - EN - 2016-05

9

  

 2.3 I  Operati ng

• 

Check that there are no tools or other foreign objects in the machine.

• 

The panel that provides access to the technical secti on must be put in place.

• 

Set the valves as follows: valve B wide open, valves A, C, D and E closed

: water entry valve
: by-pass valve
: water exit valve
: water entry adjustment valve (opti onal)
: water exit adjustment valve (opti onal)

•  An incorrect by-pass setti  ng may cause the heat pump to malfuncti on.

• 

Check that the hydraulic correcti ons are correctly ti ghtened and that there are no leaks.

• 

Check that the device is fully stable.

• 

Set the water circulati on running.

• 

Close valve B gradually so that the fi lter pressure is increased by 150g (0.150 bars).

• 

Open valves A, C and D fully then valve E by half (the air which has built up in the heat pump condenser and the 

fi ltrati on circuit will bleed out). If valves D and E are not present, open valve A wide and close valve C by half.

•  Connect the power supply to the heat pump.

• 

If  the  heat  pump  is  on  standby 

,  press    for  3  seconds 

 appears for 2 

seconds then 

 (diff erent soft ware No. depending on the devices) for 3 seconds , and the water 

and setpoint temperatures are displayed 

, a 2 miute ti mer will start.

• 

Set the temperature you want ("setpoint" temperature).

Aft er the start-up steps for your heat pump: 

• 

 Shut down the water circulati on temporarily (by stopping the fi ltrati on or closing valve B or C) to check that you 

device stops aft er a few seconds (via the acti vati on of the fl ow rate controller).

• 

Reduce the setpoint temperature to below the water temperature to check that the heat pump stops operati ng. 

• 

Switch off  the heat pump by pressing and holding   for 3 seconds and check that it stops

.

  

 2.4 I  User functi ons

2.4.1  Adjusti ng the temperature set point:

• 

Press 

 to increase the temperature by 0.5 °C, 

• 

Press 

 to reduce the temperature by 0.5 °C.

The heat pump stops automati cally when the pool reaches the required temperature.

2.4.2 Locking/unlocking the keyboard

Press and hold 

 and 

 for 3 seconds:  

 or 

.

Summary of Contents for EverFirst 11M

Page 1: ...H0548600 B 2016 05 Instructions for installation and use English More documents on www zodiac poolcare com Z300 PM30 EverFirst EN ...

Page 2: ...r supply Do not handle the electrical elements with wet hands Clean the terminal board or the power supply socket before connection For any component or sub assembly containing a battery do not recharge or dismantle the battery or throw it into a fire Do not expose it to high temperatures or direct sunlight In stormy weather unplug the appliance to prevent it from suffering lightning damage Do not i...

Page 3: ...with the device it is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may result in material damage or serious or fatal injury and will devalidate the warranty Keep and pass on these documents for later consultation during the device s life time It is prohibited to distribute or modify this document in an...

Page 4: ...front rear connectors Anti vibration studs Attachment holes Bottom view of the appliance base for attachment to the ground and location of the anti vibration studs The device must not be installed In a location subject to high winds With the blowing towards a permanent or temporary obstacle window wall hedge awning etc less than 4 metres away Within range of water or mud jets sprays or run off take...

Page 5: ...r to work on the device water entry valve by pass valve water exit valve water entry adjustment valve optional water exit adjustment valve optional water treatment minimum distance To evacuate the condensation fit a Ø18 pipe on the grooved elbow mounted under the device base The elbow may be oriented to the rear or the side of the device Condensation drainage orientation Tip condensation drainage C...

Page 6: ...circuit breaker D curve for calibre see 5 2 I Technical specifications with a 30 mA dedicated differential circuit breaker circuit breaker or switch Additional protection may be required during installation to guarantee the II overvoltage category The electricity supply must correspond to the voltage indicated on the device s information plate The electricity supply cable must be insulated against a...

Page 7: ...e controlled by remote To do so use the remote control kit available as an option For the connection consult the manual supplied with the kit 1 4 2 Heating priority option This function helps to keep the water temperature constant by checking the water temperature at regular time intervals minimum 5 minute cycle every 60 minutes by filtration pump control The filtration is kept operating if the pool...

Page 8: ... For the connection remove the shunt between terminals 7 8 and connect the switch cable in place potential free contact no polarity 220 240V 50Hz Activate the command by pressing for 5 seconds when the regulation is not on standby then Press for 3 seconds Select Yes with then validate by pressing Press to exit heat pump terminal unit remote on off switch separate connection cable ...

Page 9: ...on run automatic circulation for at least 12 hours day the longer this time the longer the heat pump will have enough operating range to heat up Cover the basin with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night it will be even more effective if it runs during the warmest hours of the day Keep the evaporator ...

Page 10: ...valve A wide and close valve C by half Connect the power supply to the heat pump If the heat pump is on standby press for 3 seconds appears for 2 seconds then different software No depending on the devices for 3 seconds and the water and setpoint temperatures are displayed a 2 miute timer will start Set the temperature you want setpoint temperature After the start up steps for your heat pump Shut d...

Page 11: ...r the interface 2 languages available French and English reversible models only Select the device s operating mode Water heating only Water heating or cooling automatic according to need The light must be fixed No water flow Water flow too low or Water flow too high or Set the rate using valve E or C if no valve E In this setting phase wait a few minutes after each valve position change for the device...

Page 12: ... wintering micro cover provided on the heat pump 3 2 I Maintenance It is recommended that the device be general serviced at least on a yearly basis to ensure proper operation maintain performance levels and prevent some potential failures These operations are carried out at the user s expense by a technician 3 2 1 User maintenance Make sure that the filter is not blocked by any foreign bodies Clean...

Page 13: ... converted to gas If your heat pump is not in its defrost cycle this is not normal Switch off and disconnect the heat pump immediately and contact your reseller The device is not working If there is no display check the supply voltage and the F1 fuse When the setpoint temperature is reached the heat pump stops heating the water temperature is higher than or equal to the setpoint temperature When th...

Page 14: ...Automatic if fewer than 4 faults per hour or press faults per hour Cooling circuit high pressure fault Exchanger clogged with dirt Clean the water exchanger Automatic if fewer than 4 faults per hour or press faults per hour Insufficient water flow Increase flow using by pass check that the pool filter is not clogged Air and water emulsion passed into the device Check the pool s hydraulic circuit Flow c...

Page 15: ...on the link cable between the boards By electricity supply disconnection or automatic if the fault disappears Board power supply fault Check the boards power supply Faulty boards Replace the boards 4 3 I Additional menus To access the menu press To browse the menus and modify the values press or To exit the menu press You may consult the latest faults You may read the values measured by the sensor...

Page 16: ...H0548600 B EN 2016 05 15 4 4 I Wiring diagrams 4 4 1 Z300 M4 M5 M7 PM3041 PM3051 PM3061 EverFirst 8M 11M 13M 4 4 2 Z300 T5 PM3053 EverFirst 11T ...

Page 17: ...16 H0548600 B EN 2016 05 4 4 3 Z300 MD5 PM3052 EverFirst 11MD 4 4 4 Z300 MD8 PM3072 EverFirst 15MD EN ...

Page 18: ...LP Low pressure switch ST5 Compressor backflow sensor C1 Ventilator condenser VA Varistor C2 Compressor condenser BLU Blue C3 Filter WHT White D1 Progressive starter GRY Grey EXP VALVE Electronic regulator YEL YELLOW F1 3 15A 250V protection fuse BRN Brown HEATER Anti freeze resistance condenser BLK Black HP High pressure switch ORG Orange J1 Flow controller RED Red M1 Ventilator motor PNK Pink M2 ...

Page 19: ...chnical compartment A Z300 PM30 EverFirst B Ø50 connector to be glued x2 C Gland D Anti vibration studs x5 E Wintering cap x2 F Wintering cover Heating priority G Remote control H Plant room kit I Condensate pan J PAC NET cleaning product supplied available as an accessory EN ...

Page 20: ...e category II Nominal absorbed intensity A 7 9 10 3 4 25 13 10 4 4 16 7 4 Maximum absorbed intensity A 10 13 4 7 15 7 12 8 5 24 9 3 Minimum cable section mm 3x2 5 3x2 5 5x2 5 3x4 3x2 5 5x2 5 3x6 5x2 5 3G2 5 3G2 5 5G2 5 3G4 3G2 5 5G2 5 3G6 5G2 5 Proof pressure bar 3 Service pressure bar 1 5 Head loss mCE 1 4 1 5 1 5 1 5 1 5 1 5 1 1 1 1 Medium water flow m h 4 5 5 6 5 5 6 5 6 5 Values provided for in...

Page 21: ......

Page 22: ... 49180 St Barthélémy d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Modèle appareil Appliance model Numéro de série Serial number Trouvez plus d informations et enregistrez votre produit sur More informations and register you product on www zodiac poolcare com ...

Reviews: