WARNINGS

• Failure to respect the warnings may cause serious damage to the pool equipment or cause serious injury, even 

death.

• 

The appliance is intended for a specifi c pool use and must not be used for any use other than that for which it was 

designed.

• 

It is important that the equipment is operated by competent and qualifi ed (both physically and mentally) people 

who have previously received the instructi ons for use. All persons not meeti ng these criteria must not approach the 

appliance in order to avoid exposure to dangerous elements.

• Keep the appliance out of the reach of children.

• 

The device must be installed by a qualifi ed technician according to the manufacturer’s instructi ons and in compliance 

with local regulati ons. The installer is responsible for installati on of the equipment and for compliance with nati onal 

installati on  regulati ons.  Under  no  circumstances  can  the  manufacturer  be  held  liable  in  the  event  of  failure  to 

comply with applicable local standards.

• 

Incorrect installati on and/or use may cause serious damage to property or serious injuries (possibly causing death). 

• 

All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The consignee shall make 

reservati ons in writi ng on the carrier’s bill of lading if damage is detected, caused during transport (confi rmati on to 

be sent to the carrier within 48 hours by registered mail with acknowledgement of receipt). In the event of a device 

containing coolant that has been turned on its side, menti on your reservati ons in writi ng to the carrier.

• 

If the appliance suff ers a malfuncti on, do not try to repair the appliance yourself, contact a qualifi ed technician.

• 

Refer to the warranty conditi ons for details of the permitt ed water balance values for operati ng the appliance.

• 

Eliminati ng or shunti ng one of the safety devices automati cally voids the warranty, as does the replacement of parts 

using parts not manufactured by ourselves.

• 

Do not spray insecti cide or any other chemical (infl ammable or non-infl ammable) in the directi on of the appliance, 

as this may damage the body and cause a fi re.

• 

Heat pump, fi ltrati on pump and fi lter appliances are compati ble with all types of water treatment.

• 

For heat pump appliances or dehumidifi ers, do not touch the fan or insert a rod or your fi ngers through the grati ng 

when the appliance is in operati on. The fan rotates at high speed and may cause injuries or even death.

• 

The electrical supply to the appliance must be protected by a dedicated 30 mA diff erenti al residual current protecti on 

device, complying with the standards and regulati ons in force in the country where it is installed.

• 

Means for disconnecti on from the supply mains having a contact separati on in all poles that provide full disconnecti on 

under overvoltage category III, must be incorporated in the fi xed wiring in accordance with the wiring rules.

• 

Before carrying out any operati ons, check that:

 -

The voltage indicated on the maker’s plate of the appliance corresponds to the mains voltage, 

 - The power grid is adapted to the power requirements of the appliance, and is grounded. 

 -

The plug (where applicable) is suitable for the socket.

• 

In the event of abnormal functi on or the release of odours from the appliance, turn it of immediately, unplug it from 

its power supply and contact a professional.

• 

Before any interventi on on the appliance, ensure that the latt er is switched off  and disconnected from the power 

supply,  in  additi on  to  any  other  equipment  connected  to  the  appliance,  and  that  the  heati ng  priority  (where 

applicable) is deacti vated.

• 

Do not disconnect and reconnect the appliance to the power supply when in operati on.

• Do not pull on the power cord to disconnect it from the power supply.

• Do not handle the electrical elements with wet hands.

• 

Clean the terminal board or the power supply socket before connecti on.

• 

For any component or sub-assembly containing a batt ery: do not recharge or dismantle the batt ery, or throw it into 

a fi re. Do not expose it to high temperatures or direct sunlight.

• 

In stormy weather, unplug the appliance to prevent it from suff ering lightning damage.

• 

Do not immerse the appliance in water (with the excepti on of cleaners) or mud.

• 

Do not discharge R410A or R407C fl uid into the atmosphere. These are fl uorinated greenhouse eff ect gases, covered 

by the Kyoto Protocol, with a Global Warming Potenti al (GWP) = 1975 for R410A or 1653 for R407C - (Directi ve EC 

842/2006).

• 

According to French decree No. 2007-737, if the appliance has more than 2 kg of refrigerant gas (refer to manufacturer 

specifi cati ons), the cooling circuit must be checked for leakage at least once a year. This operati on must be carried 

out by a certi fi ed cooling appliance specialist.

Additi onal recommendati ons in relati on to the Pressure Equipment Directi ve (PED-97/23/EC)

Installati on and maintenance

The unit may not be installed close to combusti ble materials, or the air duct inlet of an adjacent building .

With some devices, it is essenti al to fi t protecti on grids if the unit is installed in an area with uncontrolled access.

During installati on, troubleshooti ng and maintenance, pipes may not be used as steps: the pipe could break under the weight, 

spilling refrigerant and possibly causing serious burns.

When servicing the appliance, the compositi on and state of heat carrying fl uid must be checked, as well as the absence of any 

refrigerant.

During the annual unit sealing test in accordance with applicable legislati on, the high and low pressure switches must be 

checked to ensure that they are securely fastened to the coolant circuit and that they cut-off  the electrical circuit when tripped.

During maintenance work, ensure there are no traces of corrosion or oil around cooling components.

Before beginning work on the cooling circuit, stop the device and wait for a few minutes before fi tti  ng the temperature and 

pressure sensors. Some elements such as the compressor and piping may reach temperatures in excess of 100°C and high 

pressures with the consequent risk of severe scalding. 

T

roubleshooti ng

All soldering work must be carried out by a someone qualifi ed to do so.

Replacement pipes must always be made of copper in compliance with standard NF EN 12735-1.

Leak detecti on, pressure test:

 -

never use oxygen or dry air, risk of fi re or explosion, 

 -

use dry nitrogen or the mixture of nitrogen and refrigerant indicated on the informati on plate, 

 -

the test pressure for both the high and low pressure circuits must not exceed 42 bar (for R410A), 20 bar and 15 bar (for 

R407C) in the case the device is equipped with the opti onal pressure gauge.

The  high pressure circuit  pipes  are made of  copper  and  have a diameter equal  to  or greater than  1’’5/8. A certi fi cate as 

indicated  in  §2.1  in  compliance  with  standard  NF  EN  10204 will  be  requested  from  the  supplier  and  fi led  in  the  facility’s 

technical documentati on.

Technical data relati ve to the safety requirements of the various applicable directi ves must be indicated on the informati on 

plate. All this informati on must be recorded in the unit’s installati on manual, which must be kept in the technical fi le of the 

unit: model, code, serial number, maximum and minimum OT, OP, year of manufacture, EC label, manufacturer’s address, 

refrigerant and weight, electrical parameters, thermo-dynamic and acousti c performances

Recycling

This symbol means that your appliance must not be thrown into a normal bin. It will be selecti vely collected for the 

purpose  of  reuse,  recycling  or  transformati on.  Any  substances  it  may  contain  which  are  potenti ally  dangerous  to  the 

environment shall be eliminated or neutralised.

Request informati on on recycling procedures from your retailer.

Summary of Contents for EverFirst 11M

Page 1: ...H0548600 B 2016 05 Instructions for installation and use English More documents on www zodiac poolcare com Z300 PM30 EverFirst EN ...

Page 2: ...r supply Do not handle the electrical elements with wet hands Clean the terminal board or the power supply socket before connection For any component or sub assembly containing a battery do not recharge or dismantle the battery or throw it into a fire Do not expose it to high temperatures or direct sunlight In stormy weather unplug the appliance to prevent it from suffering lightning damage Do not i...

Page 3: ...with the device it is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may result in material damage or serious or fatal injury and will devalidate the warranty Keep and pass on these documents for later consultation during the device s life time It is prohibited to distribute or modify this document in an...

Page 4: ...front rear connectors Anti vibration studs Attachment holes Bottom view of the appliance base for attachment to the ground and location of the anti vibration studs The device must not be installed In a location subject to high winds With the blowing towards a permanent or temporary obstacle window wall hedge awning etc less than 4 metres away Within range of water or mud jets sprays or run off take...

Page 5: ...r to work on the device water entry valve by pass valve water exit valve water entry adjustment valve optional water exit adjustment valve optional water treatment minimum distance To evacuate the condensation fit a Ø18 pipe on the grooved elbow mounted under the device base The elbow may be oriented to the rear or the side of the device Condensation drainage orientation Tip condensation drainage C...

Page 6: ...circuit breaker D curve for calibre see 5 2 I Technical specifications with a 30 mA dedicated differential circuit breaker circuit breaker or switch Additional protection may be required during installation to guarantee the II overvoltage category The electricity supply must correspond to the voltage indicated on the device s information plate The electricity supply cable must be insulated against a...

Page 7: ...e controlled by remote To do so use the remote control kit available as an option For the connection consult the manual supplied with the kit 1 4 2 Heating priority option This function helps to keep the water temperature constant by checking the water temperature at regular time intervals minimum 5 minute cycle every 60 minutes by filtration pump control The filtration is kept operating if the pool...

Page 8: ... For the connection remove the shunt between terminals 7 8 and connect the switch cable in place potential free contact no polarity 220 240V 50Hz Activate the command by pressing for 5 seconds when the regulation is not on standby then Press for 3 seconds Select Yes with then validate by pressing Press to exit heat pump terminal unit remote on off switch separate connection cable ...

Page 9: ...on run automatic circulation for at least 12 hours day the longer this time the longer the heat pump will have enough operating range to heat up Cover the basin with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night it will be even more effective if it runs during the warmest hours of the day Keep the evaporator ...

Page 10: ...valve A wide and close valve C by half Connect the power supply to the heat pump If the heat pump is on standby press for 3 seconds appears for 2 seconds then different software No depending on the devices for 3 seconds and the water and setpoint temperatures are displayed a 2 miute timer will start Set the temperature you want setpoint temperature After the start up steps for your heat pump Shut d...

Page 11: ...r the interface 2 languages available French and English reversible models only Select the device s operating mode Water heating only Water heating or cooling automatic according to need The light must be fixed No water flow Water flow too low or Water flow too high or Set the rate using valve E or C if no valve E In this setting phase wait a few minutes after each valve position change for the device...

Page 12: ... wintering micro cover provided on the heat pump 3 2 I Maintenance It is recommended that the device be general serviced at least on a yearly basis to ensure proper operation maintain performance levels and prevent some potential failures These operations are carried out at the user s expense by a technician 3 2 1 User maintenance Make sure that the filter is not blocked by any foreign bodies Clean...

Page 13: ... converted to gas If your heat pump is not in its defrost cycle this is not normal Switch off and disconnect the heat pump immediately and contact your reseller The device is not working If there is no display check the supply voltage and the F1 fuse When the setpoint temperature is reached the heat pump stops heating the water temperature is higher than or equal to the setpoint temperature When th...

Page 14: ...Automatic if fewer than 4 faults per hour or press faults per hour Cooling circuit high pressure fault Exchanger clogged with dirt Clean the water exchanger Automatic if fewer than 4 faults per hour or press faults per hour Insufficient water flow Increase flow using by pass check that the pool filter is not clogged Air and water emulsion passed into the device Check the pool s hydraulic circuit Flow c...

Page 15: ...on the link cable between the boards By electricity supply disconnection or automatic if the fault disappears Board power supply fault Check the boards power supply Faulty boards Replace the boards 4 3 I Additional menus To access the menu press To browse the menus and modify the values press or To exit the menu press You may consult the latest faults You may read the values measured by the sensor...

Page 16: ...H0548600 B EN 2016 05 15 4 4 I Wiring diagrams 4 4 1 Z300 M4 M5 M7 PM3041 PM3051 PM3061 EverFirst 8M 11M 13M 4 4 2 Z300 T5 PM3053 EverFirst 11T ...

Page 17: ...16 H0548600 B EN 2016 05 4 4 3 Z300 MD5 PM3052 EverFirst 11MD 4 4 4 Z300 MD8 PM3072 EverFirst 15MD EN ...

Page 18: ...LP Low pressure switch ST5 Compressor backflow sensor C1 Ventilator condenser VA Varistor C2 Compressor condenser BLU Blue C3 Filter WHT White D1 Progressive starter GRY Grey EXP VALVE Electronic regulator YEL YELLOW F1 3 15A 250V protection fuse BRN Brown HEATER Anti freeze resistance condenser BLK Black HP High pressure switch ORG Orange J1 Flow controller RED Red M1 Ventilator motor PNK Pink M2 ...

Page 19: ...chnical compartment A Z300 PM30 EverFirst B Ø50 connector to be glued x2 C Gland D Anti vibration studs x5 E Wintering cap x2 F Wintering cover Heating priority G Remote control H Plant room kit I Condensate pan J PAC NET cleaning product supplied available as an accessory EN ...

Page 20: ...e category II Nominal absorbed intensity A 7 9 10 3 4 25 13 10 4 4 16 7 4 Maximum absorbed intensity A 10 13 4 7 15 7 12 8 5 24 9 3 Minimum cable section mm 3x2 5 3x2 5 5x2 5 3x4 3x2 5 5x2 5 3x6 5x2 5 3G2 5 3G2 5 5G2 5 3G4 3G2 5 5G2 5 3G6 5G2 5 Proof pressure bar 3 Service pressure bar 1 5 Head loss mCE 1 4 1 5 1 5 1 5 1 5 1 5 1 1 1 1 Medium water flow m h 4 5 5 6 5 5 6 5 6 5 Values provided for in...

Page 21: ......

Page 22: ... 49180 St Barthélémy d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Modèle appareil Appliance model Numéro de série Serial number Trouvez plus d informations et enregistrez votre produit sur More informations and register you product on www zodiac poolcare com ...

Reviews: