background image

 2 

1. GENERAL 

 

1.1 General terms of delivery 

 

Any equipment, even CARRIAGE and PACKING FREE, travel at the consignee’s risk. The consignee shall make 
reserves in writing on the CARRIER’S delivery bill if he notes damage caused during transport. (Confirmation to be sent 
to the CARRIER within 48 hours by registered mail with acknowledgement of receipt). 

 

Reminder:

 

The unit must be shipped and stored in the upright position on a pallet and in the original packaging

. In the contrary 

case, place the unit in the vertical position on the pallet and check its global state (in case of doubt regarding the unit’s good state of 
operation establish reserves in writing with the carrier). 

 

-

 

Under no circumstances may the heat pump be operated immediately if it was placed horizontally. 

Wait at least 12 hours before operating the pump -

 

 

1.2 Voltage 

 

Prior to any operation, check that the voltage on the name plate of the appliance corresponds to the mains voltage 
provided on site. 

 

1.3 Water treatment 

 

In order to use our appliances under the best conditions, the following parameters must be respected: free chlorine: max. 
2.5 mg/l, total bromine: max. 5.5 mg/l, pH between 6.9 and 8.0. If chemical or electrophysical disinfection systems are 
used, the installer and user must contact the supplier to ensure they are compatible with our materials. These systems must 
be installed after the heating system. 

 

2. DESCRIPTION 

 

2.1 Presentation 

 

Contents after unpacking

:   

 

The unit with its instructions, warranty card  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Note:

 inside the appliance you will find a sachet of accessories. To extract it, see paragraph 4.1 of these instructions.

 

 
 
 
 
 
                                                                                                                                                                                                                     

 

 

 

Content of sachet: 

two half-union connectors Ø50 with strap   + two sealing rings   - four silent blocks   

 a grooved elbow union  .- a plastic cap 

- four anchor bolts and dowels 

(only supplied with double fan unit

).

 

 

 

 

Must

 be installed 

with a double fan 

machine 

Summary of Contents for Edenpac 2

Page 1: ...gle fan 4 1 2 Edenpac with double fan 4 2 Hydraulic connections 10 4 3 Electric connection 11 5 Regulator operation 12 5 1 Presentation 12 5 2 Setting the target temperature 12 6 Starting up 13 6 1 Ch...

Page 2: ...2 Voltage Prior to any operation check that the voltage on the name plate of the appliance corresponds to the mains voltage provided on site 1 3 Water treatment In order to use our appliances under th...

Page 3: ...ANIUM condenser unit 8 Regulator sensor 9 LP pressure switch Cased SCROLL compressor 11 Arched flat fin unit cooler 12 Anti frost sensor 13 Fastening plates with silent blocks 14 Pool inlet water conn...

Page 4: ...e on photos but located at the back of the unit 1 2 3 4 6 5 7 8 9 11 13 1 Top and bottom panels with polypropylene grid 2 Motor fan unit 3 Access flap to digital regulator 3a Euro FK and pressure gaug...

Page 5: ...ions of the appliance with packaging in mm Weight of Edenpac 2 with packaging 98 kg Weight of Edenpac 3 with packaging 101 kg Weight of Edenpac 4 5 with packaging 110 kg 1275 480 870 To be transported...

Page 6: ...6 2 2 2 Edenpac 6...

Page 7: ...anner 13 1 ratchet spanner 1 pliers 2 straps for handling Choose the appliance installation site according to the following criteria the appliance must be installed outdoors the clearance around the a...

Page 8: ...re are not water jets In the contrary case respect a minimum distance of 3 5 metres Attention Do not lift the appliance by picking it up at the front and or the water inlet outlet points Use 2 lifting...

Page 9: ...crews 2 and 3 on the right side using a cross head screwdriver Slide the entire front panel forward and then down 4 1 2 Edenpac with double fan Turn the 2 clips 1a and 1b in the front turn clockwise u...

Page 10: ...ent facility see diagrams below Hydraulic circuit test pressure 3 bar Hydraulic circuit operating pressure 1 5 bar Edenpac 2 3 4 and 5 Average water flow 5 to 6 5 m3 h pressure drop 1 3 to 1 7 mCE 0 1...

Page 11: ...olarity 230V 50Hz between terminals 1 2 refer to the electrical wiring diagram below Possibility to connect an exterior fault indicator of 230V 50Hz between terminals 0 and 4 refer to the electrical w...

Page 12: ...f the water temperature becomes or is lower than the target temperature the regulator unit authorises heating after a set time of 180 seconds the Led blinks and then remains on 5 2 Setting the target...

Page 13: ...at the base of the unit may be due to normal condensation of the water vapour in the air or due to the defrost cycle in progress phenomenon visible if the additional condensation evacuation kit is not...

Page 14: ...d longer than or equal to 3 s a timer of 130 seconds min is activated before the unit starts again For information this time period may increase during a defrost cycle or if the compressor stop time i...

Page 15: ...ne hour Consult a PSA approved technician to check the sensor and operation of the defrost cycle Cut power supply or press the button if dtd starts blinking after stand by Ofr5 and switch the regulato...

Page 16: ...g operations must be carried out at least once a year Clean the evaporator at the back of the heat pump with a soft brush and gentle water spray Never use a high pressure cleaner for this operation Ch...

Page 17: ...17 9 ELECTRICAL DIAGRAMS 9 1 Electrical diagram of connection interface card To J11 and J12 To J6 and J14...

Page 18: ...18 9 2 Electrical diagram EdenPAC single phase IMPORTANT Elimination or shunting of one of the safety or remote control devices automatically cancels the GUARANTEE...

Page 19: ...19 9 3 Electrical diagram EdenPAC three phase IMPORTANT Elimination or shunting of one of the safety or remote control devices automatically cancels the GUARANTEE...

Page 20: ...or shunting of one of the safety or remote control devices automatically cancels the GUARANTEE With an aim to improving its products PSA reserves the right to modify the characteristics without prior...

Reviews: