Zodiac Chlor Perfect Instructions For Installation And Use Manual Download Page 11

9

 2.2. Sensor and injecti on point installati on

• 

There must be at least 60 cm linear between the sensor and the injecti on point. If this is not possible, use 

the POD kit available as an opti on or a check valve.

• 

Fixture collars (or the POD kit) must be installed on rigid Ø50 PVC pipes. A Ø63 adapter is available as an 

opti on.

• 

The POD kit is recommended if a pH regulati on module has also been installed.

• 

Maximum pressure must not exceed 1.5 bar.

• 

Drill a hole with a diameter between 16 and 22 mm on the pipe at the selected locati ons for the ORP sensor 

and the injecti on point.

• 

Then install the fi xture collars.

• 

Use Tefl on tape to make sure the threads on the sensor holder, the injecti on valve and its adapter are 

waterti ght.

• 

Screw down the one or more sensor holders onto the fi xture collar or a POD kit (opti onal), 

see illustra� on 

.

• 

Carefully unscrew the protecti on tube from the sensor, 

see illustra� on  . Retain the protec� on tube for 

use when the sensor is stored during the winter.

• 

Rinse the end of the sensor with tap water and shake off  excess water, 

see illustra� on  .

•  Never wipe the sensor using a cloth or paper � ssue, as this may damage it!

•  A badly-installed sensor may give false readings and cause inappropriate opera� on of the 

appliance. Neither the manufacturer nor the appliance shall be liable in this event.

• 

Screw the sensor into the sensor holder, holding the YELLOW connector in one hand and the black connector 

in the other to avoid tangling the cable, 

see illustra� on  .

• 

Once the sensor is installed, it can be connected to the BNC connector's control box, 

see "1.3 I  Dimensions 

and marking".

EN

Summary of Contents for Chlor Perfect

Page 1: ...H0435000 G 2019 11 More documents on www zodiac com EN Instruc ons for installa on and use English Redox regulation Translation of the original instructions in french...

Page 2: ......

Page 3: ...onsible for installing the appliance and for compliance with national installation regulations Under no circumstances may the manufacturer be held liable in the event of failure to comply with applica...

Page 4: ...f overheating such as a burning odour from the appliance turn it of immediately unplug disconnect it from its power supply and contact a professional Before accessing the enclosure for any reason ensu...

Page 5: ...t you read this installa on and user manual as well as the warnings and warranty booklet delivered with the appliance Failure to do so may result in material damage or serious or fatal injury and will...

Page 6: ...G Wall mounting bracket kit H 465 mV buffer solution 1 2 I Technical speci ca ons Power supply voltage 220 240 VAC 50 Hz 1 phase Electric output 9W Protection index IP65 Maximum peristaltic pump ow 1...

Page 7: ...ump Master switch BNC connector socket for ORP sensor Cable gland for direct coupling with the filtering system Connector for suction tube Connector for injection tube Cable gland for suction cane cab...

Page 8: ...eters Unit Recommended values To increase To decrease Test frequency during the season pH 7 2 7 4 Add pH or use pH regulation module Add pH or use pH regulation module Weekly Free chlorine mg L or ppm...

Page 9: ...onality adjusts automatically and the balancing between the different doses is made in 70 mV steps The appliance uses measurements of the disinfectant capacity of the water ORP potential to determine...

Page 10: ...ORP sensor must not be in contact with the pipe Never install a ORP sensor before the filtering pump or between the pump and the filter This would cause random readings and a shortened service life Th...

Page 11: ...d its adapter are watertight Screw down the one or more sensor holders onto the fixture collar or a POD kit optional see illustra on Carefully unscrew the protection tube from the sensor see illustra...

Page 12: ...ng the supplied fixture kit install the control box on a rigid vertical surface in an easy access location Connect the power cord to a 230Vac mains outlet Connect the stripped wire to couple the filtr...

Page 13: ...w the water disinfectant capacity ORP potential at all times The sensor can also be calibrated when filtering is stopped The appliance can be powered off at all times using the 0 1 switch on the side...

Page 14: ...ace the buffer solution and or the ORP sensor restart calibration press to complete calibration Rinse the tip of the ORP sensor with tap water Shake it to remove excess water Fit the sensor back onto...

Page 15: ...ration Activated On Filtering operation detection Activated On Press and at the same time and hold for 5 seconds when the appliance is powered on To exit this menu press Select Yes or No using the and...

Page 16: ...programmed time has elapsed without having reached the set point is displayed when the time has elapsed The appliance then switches to safety mode If filtering stops and restarts daily cycles while t...

Page 17: ...function can however be deactivated in the case of a different electrical connection only carried out by a professional The appliance will no longer take ltering status into considera on and may injec...

Page 18: ...using Then pass the tube into the roller holder guide Turn the roller holder clockwise and accompany the tube as far as the right fitting Refit the peristaltic pump cover 4 2 I Winterizing Always keep...

Page 19: ...Replace the ORP sensor The ORP sensor cable is too close to an electric cable causing interference Reduce the distance between the appliance and the sensor Place the sensor in a more suitable locatio...

Page 20: ...t test if the OFA Stop was activated during the previous filtering cycle Wait for the end of the procedure 1 hour then check the sensor and or the pool chlorine level Filtering Filtering stopped Start...

Page 21: ...23 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d...

Reviews: