Page 15
AquaLink
®
TRi
®
Controller | Installation Manual
Page 14
AquaLink
®
TRi
®
Controller | Installation Manual
6.5.3
Test Pool heater ON/OFF
MAIN > DEVICES > POOL HEATER
1. Highlight POOL HEATER and press Select.
2. Scroll up/down to set temperature then press
Select. After a couple of minutes, you should hear
the pool heater go on.
Zodiac
12:40PM
Pool Mode
Off
Pool Heater
26°F
Spa Mode
Off
Spa Heater
Off
Settings
>
Devices
>
Zodiac
12:40PM
Pool Mode
Off
Pool Heater
Off
Spa Mode
Off
Spa Heater
Off
Settings
>
Devices
>
Filter Pump
Aux1
Aux2
POOL HEAT
Enabled
Set to: 28°F
Devices
Filter Pump
Off
Spa
Off
Pool Heat
Off
Spa Heat
Off
Solar Heat
Off
More
Pool Heat
Enabled
Set to: 80°F
6.5.4
Test Spa heater ON/OFF
(if applicable)
NOTE:
To test the spa heater installation, first turn on
the auxiliary JVA associated with the spa (see
Section 7.10 Assign JVA
) and wait 35 seconds
before turning on the spa heater through the UI.
MAIN > DEVICES > SPA HEATER
Zodiac
12:40PM
Pool Mode
On
Pool Heater
26°C
Spa Mode
Off
Spa Heater
Off
AUX1
>
AUX2
>
Settings
>
Devices
>
Devices
Filter Pump
Off
Spa Pump
Off
Pool Heat
Off
Spa Heat
On
Solar Heat
Off
More
Manual Control
Filter Pump
Off
Spa
Off
Pool Heat
Off
Spa Heat
Off
Solar Heat
Off
More
Spa Heat
Enabled
Set to: 38°C
1. Highlight SPA HEATER and press Select.
2. Scroll up/down to set temperature then press
Select. After a couple of minutes, you should hear
the spa heater go on.
Section 7. Install Settings
Install Settings is a hidden menu, mostly used for setup
and reference purposes.
Settings available through this menu:
•
Freeze Protect
Automatically turn specific equipment on to protect
against freezing temperatures.
•
Units
Change units of measurement displayed on the User
Interface (temperature and time format).
•
Language
Change language displayed on the User Interface.
•
Clear Memory
Clear all programmed data in the controller for all
equipment.
•
Pump
Assign a one-speed, two-speed pump or variable-speed
pump to the controller.
•
Color Lights
Only available if specific lights are installed in your
configuration.
•
Label Aux
Assign custom labels to auxiliary equipment, such as an
air blower, cleaner, solar pump, etc.
•
Temp Calibrate
Adjust temperature displayed on the User Interface up or
down by four (4) degrees.
•
Solar Priority
Only available if solar heating is installed in your system.
•
Assign JVA
Assign Jandy Valve
®
Actuators (JVAs) to specific AUX
relays, as intake or return in Pool Only mode.
•
Ext. SWC Power
Only available if a compatible salt water chlorinator
(SWC) is installed in your configurations.
•
Assign hotkeys
Only available if AquaPalm
™
is installed with your
configuration.
•
Diagnostics
Display software revision information and alerts for
troubleshooting purposes.