Each piece of non-related pool equipment requiring a
ground should also be bonded to the common, approved
bonding point. There should be one bonding connection
to the power pack. In Canada, the Canadian Electrical
Code (CEC) dictates that the bonding conductor be,
minimum 13.3 mm
2
(6 AWG).
3.7
Split Return Plumbing Instructions:
For Infloor Cleaning Systems
If the chlorinator is used with an in-floor cleaning
system, it must be installed in a separate dedicated
return line or damage to the chlorinator will occur.
NOTE
Do not install the chlorinator on in-floor systems that do
not have a dedicated pool return as shown in Figure 5.
Figure 5.
New Pool Plumbing for In-Floor
Systems
Section 4. Pool Water
Preparation
4.1
Determining Pool Size (Litres)
•
Rectangular Pools
Length (metres) x width (metres) x average depth
(metres) x 1000 = litres capacity.
•
Circular Pools
Radius (metres) x Radius (metres) x 3.14 x average
depth (metres) x 1000 = litres capacity.
•
Oval Pools
Short Radius (metres) x long radius (metres) x 3.14
x average depth (metres) x 1000 = litres capacity.
4.2
Determining Pool Size (Gallons)
•
Rectangular Pools
Length (feet) x width (feet) x average depth (feet) x
7.5 = gallon capacity.
CELL
FROM
THE
PUMP
POOL RETURN
TO INFLOOR
CLEANER
Jandy
®
Pro Series TruClear
™
ChlorineGenerating System
|
Installation & Operation Manual
ENGLISH