Wiring

The modules use the PV-JX1203 type junction box. This box, on the back side of the module, is
weatherproof and is designed to be used with standard wiring or conduit connections. Wiring methods
should be in accordance with the NEC (National Electrical Code). Bypass diodes and cable clamps are
included with each module when shipped from the factory.

Correct wiring scheme

When designing the system, avoid forming loops to minimize risk in the event of an indirect lighting

strike. Check that wiring is correct before starting the generator. If the measured open circuit voltage
( Voc) and short-circuit current (Isc) differ from the specifications, then there is a wiring fault.

Correct connection of contact plug connectors

The plug connector has its own polarity. Make sure that the connection is safe and tight. The plug

connector should not receive outer stress. Otherwise, it is only used to connect the circuit!

Use of suitable material

Use cable extensions and plugs that are designed for outdoor application. Ensure that they are in perfect
electrical and mechanical condition. Use only cables having one conductor. Select the appropriate cable
diameter to minimize voltage drop (to calculate the minimum cable diameter and the fuse, and to
calculate controls, multiply the Isc and Voc by a factor of 1.56).

If the module is connected to the control box, you must choose the control box with LJQ-1

LJQ-3 type

Connectors.

8

Maintenance and cleaning

Do not change the PV components optionally (diode, junction box, plug connectors )

Given a sufficient tilt (at least 15°), it is not generally necessary to clean the modules (rainfall will have a

self-cleaning effect). In case of heavy soiling (which will result in output reductions), we recommend cleaning the
modules using plenty of water (from a hose) without cleaning agents and using a gentle cleaning implement (a
sponge). Dirt must never be scraped or rubbed away when dry, as this will cause micro-scratch. We recommend
that the system be inspected at regular intervals.

9

Checklists:

All fastenings are tight and secure and free of corrosion.

All cable connections are secure, tight, clean and free of corrosion.

Cables are not damaged in any way.

Check the earthing resistive of metals.

Summary of Contents for Mono-Si Series

Page 1: ...ntenance of your photovoltaic system is only carried out by qualified persons able to carry out the technical procedures described in this manual i e system planers installers and maintenance personne...

Page 2: ...se rating A 15A Nominal Mass kg 26 5kg 25 5kg 18kg 21 5kg 26 5kg 25 5kg Package Size mm 1978x992x25 27 30 35 2000x1002x25 27 30 35 1658x992x25 27 30 35 1678x1002x25 27 30 35 1978x992x25 27 30 35 2000x...

Page 3: ...r fountain Antisepsis keep away from salt erode and sulfuration places Do not wear rings jewelry watches or other metallic items while working with photovoltaic modules 3 Mounting and notes The module...

Page 4: ...be tilted for optimum winter performance As a rule if the system power output is adequate in the winter it will be satisfactory during the rest of the year The module tilt angle is measured between t...

Page 5: ...t and the bolt must be put through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or influe...

Page 6: ...dules are strong enough The modules are not subject to wind or snow loads exceeding the maximum permissible loads The module clamps which are used must not come into contact with the front glass and m...

Page 7: ...made of durable corrosion resistant and UV resistant material All mounting hardware bolt flat washer split washer nut should be stainless steel M8 size The minimum recommended length for each clamp is...

Page 8: ...on Ensure that they are in perfect electrical and mechanical condition Use only cables having one conductor Select the appropriate cable diameter to minimize voltage drop to calculate the minimum cabl...

Page 9: ...nd the inverter Be sure carefully to follow manufacture s installation instructions Artificially concentrated sunlight shall not be directed on the modules or panels 11 Danger of death from arcing Mod...

Page 10: ...d glass 8 as poly panels coated glass 9 as mono panels doped with gallium coated glass 11 12 9 10 6 7 8 5 3 4 1 2 PV modules were manufactured by ZNshine ZNSHINE PV TECH Co Ltd No 1 South Zhenxing Roa...

Page 11: ...395 Max Power Voltage Vmp V 39 8 40 40 2 40 4 Max Power Current Imp A 9 55 9 63 9 71 9 78 Open Circuit Voltage Voc V 48 5 48 7 48 9 49 1 Short Circuit Current Isc A 10 04 10 10 10 17 10 25 Module Seri...

Page 12: ...Series Fuse A 15 Electrical Performance STC Model Type ZXP6 LD72 345 P ZXP6 LD72 350 P ZXP6 LD72 355 P Max Power Pm W 345 350 355 Max Power Voltage Vmp V 38 38 2 38 4 Max Power Current Imp A 9 08 9 17...

Reviews: