ZMC432 Motion Controller User Manual V1.5
Please refer to ZBasic for details.
3.6.
Analog Output
The analog port adopts a set of 5Pin screw-type pluggable terminals with a spacing
of 3.81mm.
→
Terminal Definition
Terminal
Name
Type
Function
NC
Spare
Reserved
NC
Reserved
DA0
Output
Analog output terminal: AOUT(0)
DA1
Analog output terminal: AOUT(1)
DAGND
Public End
Analog public end
3.6.1.
Analog Output Specification & Wiring
→
Specification
Item
DA
(
0-1
)
Resolution
12-bit
Data range
0-4095
Signal range
0-10V output
Data refresh ratio
1KHz
Voltage output load
>1
KΩ
→
Wiring Reference
Summary of Contents for ZMC432