Zmodell ZM05A User Manual Download Page 7

7.

 Connecting external energy storage modules: additional power buffering 

circuit should be connected to VS (+) and GND (-) pads. In case of using energy 
storage module, energy saving mode should be turned off. Please see CV137 
in “Programming” chapter of this User’s Manual for more information.

IMPORTANT:

  It  is  not  allowed  to  connect  single  capacitors  to  these  pads 

directly. Use the following circuit diagram:

It  is  possible  to  connect  several  capacitors  in  parallel  (C1-Cx)  in  order  to 
achieve desired total capacity. Minimal recommended capacity from which the 
buffering effect becomes visible is 470 µF. Optimal capacity for reliable power 
buffering for small scales such as N and Z is 1000-2000 µF.

IMPORTANT:

 Use capacitors with a good margin of rated voltage (20-25%), 

depending  on  the  track  voltage.  For  example,  it  is  recommended  to  use 
capacitors rated for 16 V if the track voltage is 12 V. If the track voltage is 16 V, 
use capacitors rated for 25 V, and so on.

It  is  possible  to  use  different  types  of  capacitors  -  electrolytic,  Tantalum, 
polymer  and  also  ceramic  (MLCC).  In  case  of  using  polarity  sensitive 
capacitors, please always observe polarity!

Use suitable Schottky diode (D1) instead of conventional diodes in order to 
increase efficiency of buffering due to the lower voltage drop. Inductor (L1) 
should  have  sufficient  current  rating  according  to  the  total  current 
consumption of all consumers (motor, lights etc.)

It is recommended to use Zmodell energy storage modules ZM-ESM-01 or 
ZM-ESM-02*. These modules provide very good power buffering efficiency 
thanks to the high capacity packed in a very small size.

*Subject to availability; please contact your supplier.

VS

GND

ZM05A

+

+

100 µH

L1

R1

150

Ω

D1

C1

Cx

Summary of Contents for ZM05A

Page 1: ...Miniature Digital Decoder ZM05A User s Manual Art No ZM05A 1 ZM05A 2 Ver 1 07...

Page 2: ...Introduction Top Side Bottom Side Variant with connection wires M1 M2 G1 G2 GND AUX4 AUX3 LV LV VS AUX2 AUX1 LR LV M1 M2 G1 G2 GND LV LR AUX1 AUX2 VS AUX4 AUX3...

Page 3: ...onnection 1 2 LV Front light 150 mA max LR Rear light 150 mA max AUX1 AUX2 Additional functions 1 2 300 mA max AUX3 AUX4 Additional functions 3 4 unamplified 5V 20 mA max VS Supply voltage GND Ground...

Page 4: ...e digital decoder 3 Disconnect the motor and all lights of the locomotive from the tracks and make sure that both outputs of all these consumers are fully isolated from the track connections It is als...

Page 5: ...e locomotive is equipped with separately controlled white headlights and red tail lights This is the most advanced variant of controlling light functions of the locomotive It allows independent switch...

Page 6: ...dinthiscase 6 Using AUX3 and AUX4 outputs these outputs are non amplified and cannot switch high current loads They provide maximal output voltage of 5 V regardless of the track voltage Please note th...

Page 7: ...voltage 20 25 depending on the track voltage For example it is recommended to use capacitors rated for 16 V if the track voltage is 12 V If the track voltage is 16 V usecapacitorsratedfor25V andsoon I...

Page 8: ...ad out the locomotive address Program the desired locomotive address and start running the locomotive After the first check you can modify the driving parametersaccordingtoyourrequirements In case you...

Page 9: ...top 0 255 3 05 Maximum speed 0 127 92 08 Decoder reset Write 8 to this CV in order to reset the digital decoder to default settings 13 Activation F1 F8 in analog mode Bit Function Value Bit Function V...

Page 10: ...ion Range Default 51 Swapping connections Bit Function Value 0 Motor swapping M1 and M2 outputs 1 1 Light swapping LV and LR outputs 2 2 Track swapping G1 and G2 outputs 4 0 7 0 52 Dimming LV LR outpu...

Page 11: ...ports 14 28 and 126 speed steps In case the speed steps programmed on the decoder differ from those of the control device malfunctionsmayoccur This decoder supports braking with asymmetric digital vol...

Page 12: ...or disassembly of the model as well as by exceeding the maximumallowedoperatingparameters IMPORTANT Soldering work required for installation of this decoder Solderingironwiththintip 1mm andgoodsolderi...

Reviews: