14
INSTALLATION
Gas Conver
sion Pr
ocedur
e
STEP 1: PRESSURE REGULATOR
The pressure regulator supplied with the appliance is a convertible type pressure
regulator for use with Natural Gas at a nominal outlet pressure of 4˝ w.c. or LP gas
at a nominal outlet pressure of 11” w.c. and it is pre-assembled from the factory
to operate with one of these gas pressure as indicated in the labels affixed on the
appliance, package and instruction booklet.
To convert the regulator for use with other liquid propane LP gas:
1. Unscrew the front cap of the regulator (as seen below.) Inside the cap is a screw.
By hand, remove the screw to reveal a spring. Reapply the screw to the cap with
the spring revealed.
2. With the spring sticking out of the cap, reapply back to the regulator.
Any issues related to improper propane conversion are
NOT
covered under
warranty.
5/8
Rever
se r
egulator
scr
ew and spring.
Gas Conversion Procedure
WARNING
Propane
Natural Gas