background image

8

Gas Connection

Gas Connection

INSTALLATION

•  This appliance shall only be installed by an authorized professional. 
•  The appliance shall be installed in accordance with the standards of the country 

where it will be installed. The installation of this appliance must conform to local 
codes and ordinances. In the absence of local codes installation must conform 
to American National Standards, National fuel Gas code ANSI Z223.1-Latest 
edition/NFPA 54 or B 149.1.

•  The appliance, when installed, must be electrically grounded in accordance with 

local codes or, in the absence of local codes, with the National Electrical code, 
ANSI/NFPA 70.

•  If local codes permit, a flexible metal appliance connections with the new AGA 

or CGA certified design, max 5 feet (1.5m) long, 34˝m is recommended for 
connecting this appliance to the gas supply line. DO NOT bend or damage the 
flexible connector when moving the appliance. 

•  This appliance must be used with the pressure regulator provided. The regulator 

must be properly installed in order to be accessible when the appliance is 
installed in its final location. The pressure regulator must be set for the type of gas 
to be used. The pressure regulator has 34˝ female pipe thread. The appropriate 
fitting must be determined based on the size of your gas supply line, the flexible 
metal connector and the shut-off valve. 

•  The appliance must be isolated from the gas supply piping system by closing its 

individual manual shut-off valve during any pressure testing of the gas supply 
piping system at test pressures equal to or less than 34 PSI(13,8w.cpr 3,5kPA). 

•  All opening holes in the wall and floor, back and under the appliance shall be 

sealed before installation of the appliance.

 

•  A manual valve shall be installed in an accessible location in the gas line 

external to the appliance for the purpose of turning on and shutting off the gas to 
the appliance.

Do not use aerosol sprays in the vicinity of this appliance while it is hot.

WARNING

Summary of Contents for RTSBR36

Page 1: ...Rangetops Installation Guide and Users Manual...

Page 2: ...to chemicals including nickel which is known to the State of California to cause cancer For more information go to www P65Warnings ca gov ZLINE is fueled by a passion for innovation A relentless purs...

Page 3: ...ombined with durable cast iron grills both known for their even heat distribution and longevity Made by hand and innovatively designed allowing exploration for the love of food ZLINE is fueled by a pa...

Page 4: ...fire stations common areas in multi family dwellings nursing homes food service locations and institutional food service locations such as hospitals or correction facilities This warranty is non trans...

Page 5: ...l gas supply issues resulting in low gas pressure or other issues 7 Removal or re installation cost 8 Aesthetic damage scratches or natural wear caused by normal use 9 Second hand open box products or...

Page 6: ...E 3 PRODUCT DIMENSIONS 4 BEFORE INSTALLATION 5 POWER RATING ELECTRICAL CONNECTION 6 WIRING SCHEMATICS 6 GAS CONNECTION 8 GAS CONVERSION PROCEDURE 14 FINAL CHECKLIST 17 COOKTOP COOKING 18 MAINTENANCE A...

Page 7: ...rence The plug should always be accessible Installation must conform with local codes or in the absence of codes the National Fuel Gas Code NSIZ223 1 NFPA54 Electrical installation must be in accordan...

Page 8: ...any other appliance NEVER use this appliance as space heater to heat or warm the room Doing so may result in carbon monoxide poisoning and overheating of the oven NEVER cover any slots holes or passag...

Page 9: ...es with your product contact us directly at 1 614 777 5004 The ZLINE customer service team is ready to work with you on resolving your issues and assessing if further service is needed Service should...

Page 10: ...5 16 33 5 5 3 8 137 1 3 8 35 1 3 8 5 3 8 7 7 8 27 7 16 23 15 16 1 5 16 47 7 8 2 3 4 2 27 7 16 695 23 15 16 608 2 3 4 70 1 15 15 48 5 1 5 16 5 3 8 137 1 3 8 35 1 3 8 5 3 8 7 7 8 27 7 16 23 15 16 1 5 16...

Page 11: ...pproved properly sized manual shut off valve should be installed no higher than 3 above the floor and no less than 2 and no more than 8 from the right side facing product To connect gas between shut o...

Page 12: ...es is usually between these values ELECTRIC POWER RATING 120V 60HZ ELECTRICAL GROUNDING Our gas oven is equipped with a three prong plug for your protection against shock hazard and should be plugged...

Page 13: ...ICROSWITCH 5 MICROSWITCH 6 T6NN600NCN 110 120V 60Hz IGNITION ALLUMAGE RED GREEN WHITE RED GROUND WIRE Model RT RTB RTS 48 T7NN700NCN WIRE CONNECTOR MICROSWITCH 1 MICROSWITCH 2 MICROSWITCH 3 MICROSWITC...

Page 14: ...ving the appliance This appliance must be used with the pressure regulator provided The regulator must be properly installed in order to be accessible when the appliance is installed in its final loca...

Page 15: ...is appliance is shipped from the factory for use with natural gas For use with propane LP gas please follow the conversion procedure described on pg 18 A step by step conversion procedure is also incl...

Page 16: ...e responsibility of the dealer and the owner of the range to perform the appropriate gas conversion following the directions of the manufacturer The gas conversion procedure is described in this manua...

Page 17: ...ust use a heavy duty AGA design certified commercial flexible connector of at least 1 3cm IF NPT with a suitable strain relief in compliance with ANSI Z21 41 and Z21 69 standards In Massachusetts The...

Page 18: ...w Natural Gas 4 0 W c P L P Propane 10 0 W c P Incoming line pressure upstream from the regulator must be 1 W C P higher than the manifold pressure in order to check the regulator The regulator used o...

Page 19: ...if all steps are not completed Before performing the gas conversion locate the package containing the replacement nozzles which has a number indicating its flow diameter printed on the body Consult t...

Page 20: ...bels affixed on the appliance package and instruction booklet To convert the regulator for use with other liquid propane LP gas 1 Unscrew the front cap of the regulator as seen below Inside the cap is...

Page 21: ...nozzles shipped with the range using a 7 mm socket wrench Replace nozzles using the conversion set supplied with the range Each nozzle has a number indicating its flow diameter printed on the body Con...

Page 22: ...he choke screw see diagram below and turn to the right or left until the burner flame is adjusted to desired minimum 4 Make sure that the flame does not go out when switching quickly from the MAXIMUM...

Page 23: ...for leaks 6 Has the range been setup for the type of gas available in the household propane or natural gas 7 Does the flame appear sharp blue with no yellow tipping 8 Has the minimum setting for all b...

Page 24: ...in spray form never direct the spray onto the electrical wiring thermostat and bulb Ensure that air can circulate around the gas appliance Poor ventilation can result in lack of oxygen and extinguish...

Page 25: ...r MANUAL IGNITION Manual ignition is always possible even when the power is cut off or in the event of a power failure Turn the control knob counter clockwise to the MAXIMUM position light the flame w...

Page 26: ...me also at its maximum You can reduce the flame size by turning the knob in anti clockwise direction Should the burner fail to light up turn the knob to its original position and try again Your burner...

Page 27: ...sidues of the protection film after removal Cleaning the Worktop Periodically clean the burner heads the cast iron pan supports and the burner caps using warm water Remove burner food and fat residues...

Page 28: ...rner ignites but flame is large distorted or yellow The air quality of the room is affecting the flame color Ensure that there are no candles cleaning products etc in the room Low flames and longer co...

Page 29: ...Three Locations 350 Parr Circle Reno NV 89512 916 Delaware Avenue Marysville OH 43040 427 Rowland Mill Road Bruceton TN 38317 www zlinekitchen com 1 614 777 5004 1 1 0...