©2019  Guangzhou  ZHIYUAN  Electronics

 

Date: 2019/01/17

 

User Manual

 

V1.00

 

 

C

 

Guangzhou ZHIYUAN Electronics Co., Ltd.

 

 

ZDS2000B  Series  Oscilloscope  User  Manual

 

Chapter 1:Safe Precautions 

The  following  precautions  described  herein  must  be  observed  during  the  use  of  this 

instrument.  If  the  instrument  is  used  in  a  manner  not  specified  in  this  manual,  the 

protection provided by the instrument may be impaired. ZHIYUAN Electronics assumes 

no liability for the customer

’s failure to comply with these requirements. 

1.1 General Precautions 

In  order  to  avoid  injury  to  operators  and  damage  to  the  instrument  or  the  devices 

connected with the instrument, make sure to comply with the precautions below. 

Use correct power cord 

Only the dedicated power cord allowed by the country where the instrument is used can 

be used. Power cord specifications in mainland: 3

×

0.75mm

2

Ф

6.3

IEC 6022753

L=1500mm. It is used with three-pin plug and has passed CCC certification. 

Ground the instrument 

The  instrument  must  remain  grounded  through  the  protective  grounding  wire  of  its 

power cord. In order to avoid electric shock, make sure the power cord ground wire is 

properly  connected  with  protective  earth  terminal  before  connecting  any  input  and 

output terminal of the instrument.   

Connect probe correctly 

The probe

’s ground lead is at ground potential. Do not connect it to a high voltage. 

Check all ratings before use the instrument 

In order to avoid fire and high current impulse, please check all ratings and instructions 

of the instrument before use the instrument. For the detail information about all ratings, 

please refer to the related user manual. 

Use appropriate over voltage protection 

In order to avoid the electric shock to operators, make sure an over voltage (such as the 

voltage caused by thunderstorm) will not occur. 

Do not operate the instrument when the chassis is open 

Do not operate the instrument when the chassis is open. 

Use the specified power fuse 

If the power fuse is necessary to be changed, please return the instrument back to the 

factory.The  power  fuse  complied  with  the  specification  of  this  product  (Class  T,rated 

current:  2A,  rated  voltage:  250V)  will  be  replaced  by  the  maintainer  from  ZHIYUAN 

Electronics. 

Avoid exposed circuitry 

Summary of Contents for ZDS2000B Series

Page 1: ...ZDS2000B Series Oscilloscope User Manual Date 2020 01 06 V1 02 Guangzhou ZHIYUAN Electronics Co Ltd www zlg cn User Manual UM01010101...

Page 2: ...on 9 Chapter 3 Function Description 13 3 1 z Explore Waveform Zoom 13 3 1 1 Waveform Zoom 13 3 1 2 Search and marking 15 3 2 Segmented storage funciton 16 3 3 Waveform search 17 3 4 Parameter measurem...

Page 3: ...he protective grounding wire of its power cord In order to avoid electric shock make sure the power cord ground wire is properly connected with protective earth terminal before connecting any input an...

Page 4: ...antly to keep the instrument ventilated Do not use the instrument in a wet environment In order to avoid the risk of short circuit and electric shock do not operate the instrument in a wet environment...

Page 5: ...ing signs and meanings CAUTION CAUTION symbol indicates a hazard Improper handling or execution in a specified process operation and so on can lead to loss of important data or damage to the instrumen...

Page 6: ...ation Input Power ON OFF USBPort 40 years of use recyclable Do not throw the used battery into garbage bin CE Certification Each channel has 1M input resistor and 16pF input capacitor All inputs are 3...

Page 7: ...on box switch and fixed facilities such as those stationary motors permanently attached to fixed facilities IV CAT IV It is applicable to measure for the terminal of the low voltage facilities Measure...

Page 8: ...ature please make sure the air inlet and vent of the product keep the air flow freely When using the oscilloscope on the work bench please leave at least 10cm gaps on the top back and both sides of in...

Page 9: ...you can quickly view and locate abnormal signals Waveform play function In ZOOM mode use the waveform play function to quickly browse the whole waveform signal trends etc Analysis function ZDS2000B os...

Page 10: ...and knob B mainly perform menu selection or Knob A performs fine tune and Knob B performs coarse tune 4 Shortcut function keys These keys are mainly used to perform One key clearing One key persistenc...

Page 11: ...150Vrms Connecting mode Make the BNC female of the external interface connected with the BNC terminal of the oscilloscope Turn the knob to right and lock it 11 Analog channel input terminal These inpu...

Page 12: ...appropriately and use them as the bracket to make the oscilloscope upward sloping so as to leave the oscilloscope stableness for better operation and observing the display screen Open the supporting f...

Page 13: ...but also use an oscilloscope to automatically and conveniently analyze the abnormality in waveforms enabling users to locate abnormal signals within millions of waveforms without any effort Figure 3 1...

Page 14: ...zoom view mode is selected users can adjust the size of zoom window to view the waveform details Figure 3 3 Horizontal control area 2 Waveform translation in the zoom mode The large knob and time bas...

Page 15: ...n but ton with the same direction as the secondary time base waveform play to increase the waveform play speed The more times the button is pressed the faster the waveform is played Press the backward...

Page 16: ...ong time and then the waveform appears along with interference as shown in Figure 3 7 In order to facilitate analysis and save storage space the segmented storage is used to record each section of wav...

Page 17: ...eries oscilloscope has powerful real time hardware search function It provides many waveform search modes including edge pulse width cycle frequency rising falling time duty cycle and runt and sets th...

Page 18: ...nterface 3 5 Cursor Measurement Users can use the cursor measurement function to measure the X axis values such as time and Y axis values such as voltage of selected waveforms There are two pairs of m...

Page 19: ...ng Users can easily find the communication error debug hardware and accelerate the development progress through this function as shown in Figure 3 13 ZDS2000B series oscilloscope can perform 27 protoc...

Page 20: ...2 4 Analog bandwidth 3dB 200MHz 200MHz Calculated rising time 1 75ns 1 75ns Vertical resolution 8 bit Bandwidth limit 20MHz OFF Input coupling DC AC GND Input impedance 1M 1 16pF 4pF Input sensitivit...

Page 21: ...eal time sampling Maximum sampling rate 2GSa s single channel 1GSa s Multiple channel Memory depth ZDS2022B Plus ZDS2024B Plus Single channel 1 4Kpts 14Kpts 140Kpts 1 4Mpts 14Mpts 28Mpts 56Mpts 125Mpt...

Page 22: ...gand FlexRay DS18B20 PS 2 MDIO DALI HDQ 1 Wire IrDA Manchester DHT11 SHT11 Figure 4 6 Basic trigger type description Trigger Type Symbol Description Edge trigger Includes rising edge trigger falling e...

Page 23: ...unication Manchester Diff Manchester WIEGAND Miller Photo electricity DALI Infrared NEC Infrared transfer protocol analysis Philips RC 5 Philips RC 6 Industrial automation RS485 RS232 485 and 232 use...

Page 24: ...etup package to set the expansion parameters address values and port values SD_SPI SD_SPI has two sources including clock source and command source On the 20Mb s SD bus SPI mode the specific command o...

Page 25: ...rt bit of the specified package is triggered on differential Manchester bus DHT11 DHT11 has one data source The start bit is triggered on the DHT11 bus SHT11 SHT11 has one data source The specified co...

Page 26: ...s at the same time Measurement Statistics Current value maximum minimum average value standard deviation statistic times Hardware frequency meter Supported The maximum frequency is the oscilloscope ba...

Page 27: ...escription Temperature range Operation 10 40 Storage 20 70 Ingress Protection Rating IP20 Humidity range 60 relative humidity Cooling method Fan Altitude Less than 3000m operating less than 12000m non...

Page 28: ...on cable Communication between PC and oscilloscope Probe Standard configuration of a200MHz passive probe X1 and X10 range for each channel Power line For the power supply of an oscilloscope Informatio...

Page 29: ...individual or unit unauthorized commercial use of this document without prior consent of ZHIYUAN Electronics is all borne by the individual or unit themselves ZHIYUAN Electronics and partner companie...