4. Cable Diagram 

4.1 Function description of the turnstile control board 

If you are using TS3011 or TS3022, all the connections between access control and turnstile control boards are done in 
factory. Just plug in communication cable to access controller and do the setting. 

If you are using TS3000, you need to connect access control system to the main board, please check the content in this 
chapter carefully. 

Warning: 

The third party access control system lock relay trigger time should be 1 second or less than 1 second. 

 

  Figure 4-1

 

Descriptions: 

J2 Counter: 

To connect a LED screen and display the number of people passed that is generated by the push of tripod arms, 

each completed push means pass one time.

 

J5 (Left) & J4 (Right) Indicator:

 To connect a LED screen and indicate whether this passage is allowed to pass.

 

J3 Passing Indicator (top): 

To connect a LED screen and indicate if user verification is successful and whether it is able to 

pass. 

J-NC2 Disabled Turnstile: 

Short circuit NC1 and GND, the turnstile is disabled, that is to say, the turnstile is locked by force.

 

J7 Opening Signal Input:

 To receive relay signal and open the turnstile.

 S

hort circuit K1 and GND, left passing is allowed; 

short circuit K2 and GND, right passing is allowed. 

J6 External Alarm:

 Short circuit ALARM1 and GND, and the turnstile is disabled (locked) and the alarm is ringing in case 

there are emergencies. 

Summary of Contents for TS3000 Series

Page 1: ...TS3000 Series Tripod Turnstile User Manual Version 2 4 Date Jan 2018...

Page 2: ...r Arm Length mm 520 Operating Temperature 28 C 60 C Net Weight 38kg Operating Humidity 5 85 Gross Weight 43kg Flow Rate 20 30 passages minute Dimension mm Figure 1 L 940 W 260 H 980 Input Control Sign...

Page 3: ...arth 2 Power on and wait 30s for the tripod turnstile to finish the self check program 3 Lift the arms manually as shown in Figure 2 3 4 Check whether the tripod turnstile and the LED indicators work...

Page 4: ...t be connected to the ground earth there is wiring interface near the power switch Figure 3 3 3 3 Installation 1 Drilling holes Drill holes based on the locations of the holes shown in Figure 3 3 2 Fi...

Page 5: ...splay the number of people passed that is generated by the push of tripod arms each completed push means pass one time J5 Left J4 Right Indicator To connect a LED screen and indicate whether this pass...

Page 6: ...t otherwise will damage the control board 4 3 DIP K1 switch configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening Duration Direction Indicator Continue Passing Function Alar m Default...

Page 7: ...card each time this function can be enabled or disabled through number 6 in the DIP switch The description of the bit settings are as follows In the DIP switch number 6 is used to enable or disable t...

Page 8: ...t the ends of the arm is 40kg See Figure 5 1 When the impact force on the tripod turnstile reaches the designed limit the arms break down first to ensure that the whole equipment is not damaged and th...

Page 9: ...nts or drop arm solenoid 1 Check whether the stop base and turn plate withstands each other as shown in Figure 6 1 2 Check whether the drop arm solenoid is operating Check the work status of the solen...

Page 10: ...s any gap at the position shown in Figure 6 1 2 Check whether the drop arm solenoid is totally closed If not power off the equipment and power on it again 2 minutes later The turnstile allows people c...

Page 11: ...erification Interval 1s 4 Controller Communication TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function...

Page 12: ...ection Diagram of Mainboard and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to tak...

Reviews: