background image

Notes:   

1.

 

When installing the tripod turnstile against the wall, please reserve at least 100 mm space in order to open the cover 
for adjustment and maintenance.   

2.

 

The space at the end of the arm shall not be greater than 80 mm (see Figure 3-1). 

3.

 

Setting a warning line for card swiping (see Figure 3-2). A warning line is suggested to prompt users to swipe cards in a 
distance, which would greatly reduce the probability of equipment failure caused by improper operations. 

 

 

Figure 3-2 

3.2 Cabling 

As shown in Figure 3-3, the unit is millimeter. Power supply and communication wire should be deployed underground 
then into the cabinet of device. Cable protection covers are suggested to use if it is surface mounted. 

Warning

: The tripod turnstile must be connected to the ground (earth), there is wiring interface near the power switch. 

 
 
 
 
 
 

Figure 3-3 

3.3 Installation 

1.

 

Drilling holes. 
Drill holes based on the locations of the holes shown in Figure 3-3.

 

2.

 

Fix the mounting plate to its original position. 
Placing two mounting plates properly and apply screw securing glue on the surface and the threads of the expansion 
bolts, install four expansion bolts to secure two mounting plates and use a horizontal ruler to make two mounting 
plates on the same horizontal plane. If the mounting plate is not level, adjust it by the gaskets provided. Note that all the 
four expansion bolts must be installed properly, and two expansion bolts on each mounting plate. 

3.

 

Put the turnstile on two mounting plates and tighten the screws on the bottom of column, as shown in Figure 3-4. 
Adjust the direction of the turnstile, as shown in Figure 3-5. 

 
 

 

 

 

 

 

 

 

 

Figure 3-4                                             Figure 3-5 

Installation levelness

 

Installation levelness

 

Summary of Contents for TS3000 Series

Page 1: ...TS3000 Series Tripod Turnstile User Manual Version 2 4 Date Jan 2018...

Page 2: ...r Arm Length mm 520 Operating Temperature 28 C 60 C Net Weight 38kg Operating Humidity 5 85 Gross Weight 43kg Flow Rate 20 30 passages minute Dimension mm Figure 1 L 940 W 260 H 980 Input Control Sign...

Page 3: ...arth 2 Power on and wait 30s for the tripod turnstile to finish the self check program 3 Lift the arms manually as shown in Figure 2 3 4 Check whether the tripod turnstile and the LED indicators work...

Page 4: ...t be connected to the ground earth there is wiring interface near the power switch Figure 3 3 3 3 Installation 1 Drilling holes Drill holes based on the locations of the holes shown in Figure 3 3 2 Fi...

Page 5: ...splay the number of people passed that is generated by the push of tripod arms each completed push means pass one time J5 Left J4 Right Indicator To connect a LED screen and indicate whether this pass...

Page 6: ...t otherwise will damage the control board 4 3 DIP K1 switch configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening Duration Direction Indicator Continue Passing Function Alar m Default...

Page 7: ...card each time this function can be enabled or disabled through number 6 in the DIP switch The description of the bit settings are as follows In the DIP switch number 6 is used to enable or disable t...

Page 8: ...t the ends of the arm is 40kg See Figure 5 1 When the impact force on the tripod turnstile reaches the designed limit the arms break down first to ensure that the whole equipment is not damaged and th...

Page 9: ...nts or drop arm solenoid 1 Check whether the stop base and turn plate withstands each other as shown in Figure 6 1 2 Check whether the drop arm solenoid is operating Check the work status of the solen...

Page 10: ...s any gap at the position shown in Figure 6 1 2 Check whether the drop arm solenoid is totally closed If not power off the equipment and power on it again 2 minutes later The turnstile allows people c...

Page 11: ...erification Interval 1s 4 Controller Communication TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function...

Page 12: ...ection Diagram of Mainboard and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to tak...

Reviews: