Tips for di erent  ngerprint conditions

  

ZKTecos  ngerprint products are designed to verify  ngerprints with highest

  security irrespective of the conditions of the skin of the  nger. However, in case
  a  ngerprint is not read on the sensor, please refer to the followings tips.   

 

 

 

If a  nger is stained with sweat or water, scan after wiping moisture o .

 

 

If a  nger is covered with dust or impurities, scan after wiping them o .

 

 

If a  nger is  too dry, please blow some warm air from your mouth on the

   nger tip.

  

 

Tips for  ngerprint enrollment

  

In  ngerprint recognition, enrollment process is  very important. When enroll-

ing a  ngerprint, please try to place the  nger correctly with utmost care. 

 

  

 In case of low acceptance ratio, the following actions are recommended.

 

 

Delete the enrolled  ngerprint and re-enroll the  nger.

 

 

Try another  nger if a  nger is not easy to enroll due to scar or cuts.

  

In case of an enrolled  ngerprint cannot be used due to injury or  if the hand is

  full, it is recommended to enroll more than two  ngers per user. 

 

How to Place a Finger on Scanner

ZKTeco s  ngerprint readers will give optimal results for  ngerprint matching
if the following recommendations and suggestions are followed.  

Select a  nger to enroll

  

It is recommended to use an index  nger or

  a middle  nger.  

 

  

Thumb, ring or little  nger are relatively

  di cult to place in the correct position
  

 

How to place a  nger on a sensor

 

Place a  nger such that it completely covers

the sensor area with maximum contact.  

 

 

  

Place core of the  ngerprint at the center of

  the sensor. The core of a  ngerprint is a center
  where the spiral of ridges is dense. (Usually core
  of  ngerprint is the opposite side of the lower part
  of a nail.)    
 

 

  

Place a  nger such that the bottom end of a nail is

  located at the center of a sensor. 

 

Upright

Sideways

Skewed

Partial

DO NOT place the  nger in the following positions

 If a  nger is placed 
as shown on the left, 
only a small area of 
a  nger is captured. 
So it is recommended 
to place a  nger as 
shown on page 2

1

.

2.4 Inch TFT Time Attendance 

&

Access Control Terminal INSTALLATION GUIDE

2.4 Inch TFT Time

 

Attendance

 & 

Access

 

Control

 

Terminal INSTALLATION

 

GUIDE

Summary of Contents for SilkID F21-ID

Page 1: ...INSTALLATION GUIDE 2 4 Inch TFT Terminal Time Attendance Access Control ...

Page 2: ...vice next to heating equipment Be careful not to let liquid like water drinks or chemicals leak inside the device Do not let children touch the device without supervision Do not drop or damage the device Do not disassemble repair or alter the device Do not use the device for any other purpose than speci ed Clean the device often to remove dust on it In cleaning do not splash water on the device bu...

Page 3: ...er Out Sensor Button RXD GND WD1 TXD 485A GND 485B WD0 12V GND GND AUX Auxiliary In RS232 Power In RLED RJ45 1 COM1 12V BUT BELL BELL RJ45 3 GLED AL IWD0 NO1 GND RJ45 2 IWD1 NC1 GND SEN RJ45 6 BEEP AL Ethernet Alarm Wiegand In Output Wiegand Output RS485 Lock Bell Power Out Sensor Button RXD GND WD1 TXD 485A GND 485B WD0 12V GND GND AUX Auxiliary In RS232 Power In Door Sensor Auxiliary In Camera 2...

Page 4: ...ack 3 IWD1 Green 4 IWD0 White 5 6 7 Beep LED Wiegand Input Power Out Wiegand input and Power out RJ 45 1 2 3 4 5 6 7 8 1 4 PIN DESCRIPTION WIRE 1 RJ45 6 Yellow 2 RJ45 3 Green 3 RJ45 2 4 RJ45 1 TCP IP Ethernet 1 2 PIN DESCRIPTION WIRE 1 12V Red 2 Power In Power 11 12 Alarm Lock Exit Button Doorbell Door Sensor Auxiliary In GND Purble Aux Brown Red Black Gray Black Red RS485 RS232 Wiegand Out 485B Y...

Page 5: ...rent ratings 12V DC Adaptor GND 12V DC 1 2 RLED RJ45 1 COM1 12V BUT BELL BELL RJ45 3 GLED AL IWD0 NO1 GND RJ45 2 IWD1 NC1 GND SEN RJ45 6 BEEP AL Ethernet Alarm Wiegand In Output Wiegand Output RS485 Lock Bell Power Out Sensor Button RXD GND WD1 TXD 485A GND 485B WD0 12V GND GND AUX Auxiliary In RS232 Power In GND 12V DC 1 2 RLED RJ45 1 COM1 12V BUT BELL BELL RJ45 3 GLED AL IWD0 NO1 GND RJ45 2 IWD1...

Page 6: ... RJ45 6 Yellow 2 RJ45 3 Green 3 RJ45 2 4 RJ45 1 Black Red RJ 45 1 2 3 4 5 6 7 8 1 4 Network Cable Adaptor Ethernet Cable RLED RJ45 1 COM1 12V BUT BELL BELL RJ45 3 GLED AL IWD0 NO1 GND RJ45 2 IWD1 NC1 GND SEN RJ45 6 BEEP AL Ethernet Alarm Wiegand In Output Wiegand Output RS485 Lock Bell Power Out Sensor Button RXD GND WD1 TXD 485A GND 485B WD0 12V GND GND AUX Auxiliary In RS232 Power In PIN DESCRIP...

Page 7: ...5 communication wires should be a shielded and twisted pair cable RLED RJ45 1 COM1 12V BUT BELL BELL RJ45 3 GLED AL IWD0 NO1 GND RJ45 2 IWD1 NC1 GND SEN RJ45 6 BEEP AL Ethernet Alarm Wiegand In Output Wiegand Output RS485 Lock Bell Power Out Sensor Button RXD GND WD1 TXD 485A GND 485B WD0 12V GND GND AUX Auxiliary In RS232 Power In RS485 1 ProCapture 2 ProCapture 63 ProCapture RS485 B RS485 A GND ...

Page 8: ...ow Select Serial Comm Select Comm Select RS232 485 Change RS485 to master unit PIN DESCRIPTION WIRE 1 12V Red 2 GND Black 3 IWD1 Green 4 IWD0 White 5 6 7 BEEP Brown GLED Gray RLED Blue PIN DESCRIPTION WIRE 1 WD0 Green 2 WD1 White 3 GND Black 4 RXD Gray 5 6 GND Black 7 8 485B Yellow 485A Blue TXD Purple 1 7 RLED RJ45 1 COM1 12V BUT BELL BELL RJ45 3 GLED AL IWD0 NO1 GND RJ45 2 IWD1 NC1 GND SEN RJ45 ...

Page 9: ...1 12V BUT BELL BELL RJ45 3 GLED AL IWD0 NO1 GND RJ45 2 IWD1 NC1 GND SEN RJ45 6 BEEP AL Ethernet Alarm Wiegand In Output Wiegand Output RS485 Lock Bell Power Out Sensor Button RXD GND WD1 TXD 485A GND 485B WD0 12V GND GND AUX Auxiliary In RS232 Power In 1 12 FR107 Diode COM1 Device Shares Power With The Lock FR107 Diode GND NC1 Sensor Normally Closed Lock 12V DC RLED RJ45 1 COM1 12V BUT BELL BELL R...

Page 10: ...D1 WD0 GND 12V PWR RUN ACT GRD IN GND BEEP GLED WD1 WD0 GND 12V IN GND BEEP GLED WD1 WD0 GND 12V IN GND BEEP GLED WD1 WD0 GND 12V IN GND BEEP GLED WD1 WD0 GND 12V SWITCH SWITCH PC PC AUXOUT1 AUXOUT1 AUXOUT2 AUXOUT2 AUXOUT3 AUXOUT3 AUXOUT4 AUXOUT4 LOCK1 LOCK1 LOCK2 LOCK2 LOCK3 LOCK3 LOCK4 LOCK4 LOCK LOCK POWER POWER Advanced Access Control EXT RS485 CARD R IN 2 READER 2 BUTTON 3 READER 3 BU PWR GRD...

Page 11: ...4 Best Security Solution for the World Best Security Solution for the World PWR RUN ACT GRD IN GND BEEP GLED WD1 WD0 GND 12V IN GND BEEP GLED WD1 WD0 GND 12V IN GND BEEP GLED WD1 WD0 GND 12V IN GND BEEP GLED WD1 WD0 GND 12V PWR RUN ACT GRD IN GND BEEP GLED WD1 WD0 GND 12V IN GND BEEP GLED WD1 WD0 GND 12V IN GND BEEP GLED WD1 WD0 GND 12V IN GND BEEP GLED WD1 WD0 GND 12V SWITCH SWITCH PC PC AUXOUT1 ...

Page 12: ...is recommended to enroll more than two ngers per user How to Place a Finger on Scanner ZKTecos ngerprint readers will give optimal results for ngerprint matching if the following recommendations and suggestions are followed Select a nger to enroll It is recommended to use an index nger or a middle nger Thumb ring or little nger are relatively di cult to place in the correct position How to place a...

Page 13: ...n Check whether the lock open duration is set to appropriate time which opens the lock Check whether anti passback mode is in use In anti passback mode only the person who has entered through that door can exit 4 Why device display system broken and the alarm is ringing Check whether the device and back plate are securely connected to each other If not a tamper switch is activated which triggers t...

Reviews: