SBTL8000 series installation guide

  

3

 

 

 

3

 

 Debugging Functions 

 

Operating instruction 

1.

 

After powered on, the LCD screen on the control board will display the default state showing the 

current working mode. 

2.

 

There are 4 buttons on the control board: UP, DOWN, ENT, and ESC, as shown in Figure 3-1.  

UP:

 to move upwards or increase the value.  

DOWN:

 to move downwards or decrease the value. 

ENT:

 to enter a menu setting item or confirm the current modified value. 

ESC:

 to return to the previous menu or cancel the current operation. 

 

Menus  

1.

 

Position adjustment of the swing barrier  

Type: zero (default) 

Left limit 

Right limit 

2.

 

Passing mode 

Opening mode: Two-way swipe (default) 

Left free, Right swipe 

Left swipe, Right free 

Two-way free 

Left prohibit, Right swipe 

Left swipe, Right prohibit 

Left prohibit, Right free 

Left free, Right prohibit  

Two-way prohibit 

3.

 

Opening duration (Press ‘ENT’ to modify) 

After the gate is opened, it will automatically close if no one passes through within a certain time 

duration. The default value is 5 seconds. The value ranges from 2 to 60.  

 

Summary of Contents for SBTL8000 Series

Page 1: ...Installation Guide Speed gates SBTL8000 series Applicable Model s SBTL8000 SBTL8011 SBTL8022 SBTL8033 SBTL8200 SBTL8211 SBTL8222 SBTL8233 Version 1 0 Date June 2019...

Page 2: ...re power extension wire tether cable random configuration M12 expansion screws included in the package 3 Thread the connection wire of the device through the tube before assembly 4 The power and signa...

Page 3: ...onnect the master and slave devices with wires 4 Test the operations of the device after connecting it to the power supply with the temporary cable Make sure that the ground wire of AC power is connec...

Page 4: ...he current modified value ESC to return to the previous menu or cancel the current operation Menus 1 Position adjustment of the swing barrier Type zero default Left limit Right limit 2 Passing mode Op...

Page 5: ...ice alarm 6 Opening speed Speed value 1 20 default 1 7 Closing speed Speed value 1 20 default 1 8 Swiping mode Method Allow the card to be swiped in the channel default Do not allow card swiping in th...

Page 6: ...pening swift Enable or not No default Yes 16 Infrared anti pinch Mode Turn off the anti pinch feature Enabling anti pinch default 17 Infrared anti pinch area Area selection Disable during In and out o...

Page 7: ...gate unlocked Check the mode setting of the master and slave devices and the 8 core 2 core connection lines See the wiring diagram for the specific connection circuit 3 The barrier doesn t close when...

Page 8: ...SBTL8000 series installation guide 7 5 Wiring Diagram Below is the wiring diagram Figure 5 1...

Page 9: ...8 SBTL8000 series installation guide Copyright 2019 ZKTECO CO LTD All rights reserved www zkteco eu...

Reviews: